Abstract
Hard-switching-induced switching loss can contribute significantly to the power loss of an isolated bidirectional dual-active-bridge (DAB) dc-dc converter operating at high frequency. An LC-type series resonant DAB converter based on a switch-controlled-inductor (SCI) is proposed to mitigate the loss arising from hard switching under wide-range variations in output voltage and current. Zero-voltage switching is achieved at the primary side (high voltage), while at the secondary side (low voltage), zero-current switching is preferred to reduce excessive ringing due to circulating current and switching loss. In order to achieve reduced conduction loss, a nominal operating point is chosen where the root-mean-square resonant tank current is the minimum. To validate the proposed topology and modulation scheme, an LC-type series resonant DAB converter based on SCI operating at 100 kHz is designed to interface a 400-V dc bus to a supercapacitor-based energy storage. Simulation and experimental results validate the effectiveness of the proposed topology for charging/discharging a supercapacitor with an output voltage variation of between 10 and 48 V and a maximum rated power of 480 W. A maximum efficiency of 94.6% is achieved using the proposed topology and modulation scheme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Zhao, B., Yu, Q., & Sun, W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2180928 · Cited by 932 · cited 1×
“In order to reduce circulating current, an extended-phase-shift (EPS) modulation is introduced in [13]–[15], which uses an internal-phase-shift within the primary or secondary bridges, and an external-phase-shift between the primary and secondary bridges of a DAB converter for power modulation.”
BackgroundEfficiency-Optimized High-Current Dual Active Bridge Converter for Automotive Applications
Krismer, F., & Kolar, J. W. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2112312 · Cited by 747
Analysis and Design of High-Frequency Isolated Dual-Bridge Series Resonant DC/DC Converter
Li, X., & Bhat, A. K. S. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2034662 · Cited by 493 · cited 2×
“Single-phase-shift modulation is used in [8] for the design of the LC-type series resonant DAB converter.”
MethodKrismer, F., & Kolar, J. W. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2025284 · Cited by 470 · cited 3×
“, depends on Lsci) under the gridded Region B corresponds to the low output current Io at low voltage that is not covered by the SCI designed previously as supercapacitor does not typically operate in this region and ZCS can be triggered with the aid of the energy stored in the MOSFETs’ parasitic inductances during ha…”
BackgroundInfluentialEnergy Management Power Converters in Hybrid Electric and Fuel Cell Vehicles
Lai, J.-S., & Nelson, D. J. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2006.890122 · Cited by 318 · cited 1×
“The increasing penetration of renewable energy generation arises due to its positive impact on the environment by providing low carbon emissions and this has led to the development of microgrid systems [1], [2].”
BackgroundSwitching condition and loss modeling of GaN-based dual active bridge converter for PHEV charger
Xue, L., Boroyevich, D., & Mattavelli, P. (2016) · 2016 IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2016.7468038 · Cited by 28 · cited 1×
“There is an increase in the trend of high-frequency operation of the DAB converter due to the rise of new semiconductor devices with extremely low gate charge such as SiC (Silicon-Carbide) and GaN (Gallium-Nitride) [11], [12].”
Background
Cited by
Safayatullah, M., Elrais, M. T., Ghosh, S., Rezaii, R., & Batarseh, I. (2022) · IEEE Access · doi:10.1109/access.2022.3166935 · Cited by 615
“In study [149], authors have added a switchcontrolled inductor network in DAB series resonant converter (LC-type) to confirm ZVS at the primary side and ZCS at the secondary side for a wide range of battery voltage.”
BackgroundAcharige, S. S. G., Haque, M. E., Arif, M. T., Hosseinzadeh, N., Hasan, K. N., & Oo, A. M. T. (2023) · IEEE Access · doi:10.1109/access.2023.3267164 · Cited by 590
Circulating Current and ZVS-on of a Dual Active Bridge DC-DC Converter: A Review
Shao, S., Chen, H., Wu, X., Zhang, J., & Sheng, K. (2019) · IEEE Access · doi:10.1109/access.2019.2911009 · Cited by 200
“Expand ZVS-on range by paralleling a switch controlled inductor: (a) simplified circuit, (b) phasor diagram [82].”
Background
Metadata
- Authors
- Yaqoob, M., Loo, K. H., & Lai, Y. M.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2017-12
- Volume
- 32
- Issue
- 12
- Pages
- 9093-9104
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2572107140
- Cited by
- 100
- References
- 7
- FWCI
- 4.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.