Accurate Calorimetric Switching Loss Measurement for 900 V 10 m $\Omega$ SiC mosfets
The DOI matches its Crossref record.
Abstract
This letter presents and evaluates three accurate (±20 %) calorimetric switching loss measurement methods, which are capable of measuring hardand soft-switching losses at high speed (20-25 min/point) compared to other calorimetric methods. A comprehensive switching loss measurement data accuracy analysis is done, setting the benchmark for the accuracy analysis of switching loss data. The high accuracy in the switching loss data is obtained by a high ratio of switching losses to total measured losses in the Device Under Test. This is achieved by using a fullbridge configuration, where the conduction losses are reduced up to 80% in the Device Under Test by utilizing the duty cycle as an additional degree of freedom compared to a half-bridge configuration. Furthermore, the proposed calorimetric methods yield more reliable switching loss data than electrical methods, particularly than the double pulse test. Switching loss data are presented for the 900 V, 75 A, 10 mΩ SiC MOSFETs from CREE, that are one of the first discrete SiC MOSFETs to come with a TO-247-4 package.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
99% Efficient Isolated Three-Phase Matrix-Type DAB Buck–Boost PFC Rectifier
Schrittwieser, L., Leibl, M., & Kolar, J. W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2914488 · Cited by 169
Self-citationChang, F., Ilina, O., Lienkamp, M., & Voss, L. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2854756 · Cited by 111
Comparison of Wide-Band-Gap Technologies for Soft-Switching Losses at High Frequencies
Jafari, A., Nikoo, M. S., Perera, N., Yildirim, H. K., Karakaya, F., Soleimanzadeh, R., & Matioli, E. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2990628 · Cited by 92
A New Bidirectional Three-Phase Phase-Modular Boost-Buck AC/DC Converter
Menzi, D., Bortis, D., & Kolar, J. W. (2018) · 2018 IEEE International Power Electronics and Application Conference and Exposition (PEAC) · doi:10.1109/peac.2018.8590670 · Cited by 18
Self-citation
Metadata
- Authors
- Anderson, J. A., Gammeter, C., Schrittwieser, L., & Kolar, J. W.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2017-12
- Volume
- 32
- Issue
- 12
- Pages
- 8963-8968
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2611317458
- Cited by
- 77
- References
- 0
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.