A Nearest Level PWM Method for the MMC in DC Distribution Grids
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
For modular multilevel converters (MMCs) applied to medium-voltage dc distribution grids, using the traditional nearest level modulation (NLM) as in HVdc systems can lead to severe current distortion due to significantly reduced module numbers. This paper proposes a hybrid modulation method combining NLM and pulse width modulation (PWM) where only one module per arm operates under PWM mode. The proposed nearest level PWM (NL-PWM) method not only significantly reduces the current distortion, but also avoids the complicated voltage balancing control in each module. The harmonic characteristics of NL-PWM are derived using double Fourier transform, which provides a theoretical basis for selecting the module number and switching frequency for medium-voltage applications in accordance with grid harmonic requirements. Finally, the harmonic characteristics and feasibility of the proposed modulation method are validated by simulation and experimental studies on an MMC with six modules per arm. The simulated and experimental results reveal that NL-PWM has better voltage and current harmonic characteristics over NLM and CPS-PWM, thereby suiting the application of MMC with few models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387
Self-citation
Cited by
Modular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“modulated, can reduce the low-frequency current distortion generated by NLM without increasing the modulation complexity [104].”
BackgroundA SiC MOSFET and Si IGBT Hybrid Modular Multilevel Converter With Specialized Modulation Scheme
Yin, T., Xu, C., Lin, L., & Jing, K. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2993366 · Cited by 67
“Neglecting the effect of circulating current, the PWM reference uPWM and the arm current iarm can be expressed as (2) [9], where Udc and Idc are, respectively, the Fig.”
BackgroundInfluentialKadir Sheikh, S., Jain, M., & Chandrakant Tapre, P. (2025) · Tehnički glasnik · doi:10.31803/tg-20230822132129 · Cited by 2
“Numerous studies on PWM methodologies' impact on VSI in Induction motor drives, however, only address specific parameters like torque ripple and line current THD. [14].”
Metadata
- Authors
- Wang, Y., Hu, C., Ding, R., Xu, L., Fu, C., & Yang, E.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2018-11
- Volume
- 33
- Issue
- 11
- Pages
- 9209-9218
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2783174734
- Cited by
- 124
- References
- 1
- FWCI
- 4.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Nearest Level PWM Method for the MMC in DC Distribution Grids. https://app.cochat.ai/papers/10.1109/tpel.2018.2792148
- The paper
- Wang, Y., Hu, C., Ding, R., Xu, L., Fu, C., & Yang, E. (2018). A Nearest Level PWM Method for the MMC in DC Distribution Grids. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2018.2792148
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.