The DOI matches its Crossref record; the references it cites are not checked yet.
Robust Stability Analysis of LCL Filter Based Synchronverter Under Different Grid Conditions
Abstract
Synchronverters have gained interest due to their capability of emulating synchronous machines, offering selfsynchronization to the grid. Despite the simplicity of the control structure, the adoption of an LCL filter makes the overall model complex again, posing questions regarding the tuning of the synchronverter and its robustness. The multi-inputs multi-outputs (MIMO) formulation of the problem requires multivariable analysis. In this paper, the effects of control parameter and grid conditions on the stability of the system are investigated by means of structured singular values (or μ-analysis). A step-by-step design procedure for the control is introduced based on a linearized small-signal model of the system. Then, the design repercussions on the stability performance are evaluated through the performed robustness analysis. The developed linearized model is validated against time-domain simulations and laboratory experiments. These have been carried out using a power hardware-in-the-loop test bench, which allows as to test the synchronverter under different grid conditions. As a conclusion, this paper offers a simple guide to tune synchronverters but also a theoretical solid framework to assess the robustness of the adopted design.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists haven’t been fetched yet
References 26 · Cited by 89
Research works printed but not linked: 26
- 10.1109/ECCE.2017.8096930 · DOI
- 10.1109/TEC.2017.2771401 · DOI
- 10.1109/TPWRS.2015.2389822 · DOI
- 10.1109/TPEL.2014.2306432 · DOI
- skogestad, 2001, Multivariable Feedback Control
- zhou, 1998, Essentials of Robust Control
- 10.1109/IECON.2016.7793075 · DOI
- 10.1109/TPEL.2017.2668900 · DOI
- 10.1109/TIA.2005.853373 · DOI
- 10.1007/978-3-662-06948-6 · DOI
- 10.1016/j.epsr.2015.01.001 · DOI
- 10.1109/EPQU.2007.4424220 · DOI
- 10.1109/TPEL.2013.2258684 · DOI · Paper page
- 10.1109/TIE.2010.2048839 · DOI
- 10.1109/TIE.2016.2543181 · DOI
- 10.1109/TEC.2016.2645450 · DOI
- 10.1109/IECON.2017.8216078 · DOI
- 10.1109/TEC.2017.2661540 · DOI
- 10.1109/TPEL.2015.2398192 · DOI
- kundur, 1994, Power System Stability and Control
- 10.1109/TIE.2017.2652387 · DOI
- balas, 1998, $\mu$ Analysis and Synthesis Toolbox, Matlab User's Guide
- 10.1109/ECCE.2017.8095762 · DOI
- 10.1109/TIE.2017.2674611 · DOI
- 10.1109/TPEL.2014.2382565 · DOI
- 10.1109/TSG.2016.2594811 · DOI
Metadata
- Authors
- Rosso, R., Cassoli, J., Buticchi, G., Engelken, S., & Liserre, M.
- Affiliations
- University of Nottingham Ningbo China (CN)
- Christian-Albrechts-Universität zu Kiel (DE)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2019-06
- Volume
- 34
- Issue
- 6
- Pages
- 5842-5853
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2888325694
- Cited by
- 89
- References
- 26
- Citations by year
- 2026: 4 · 2025: 11 · 2024: 14 · 2023: 12 · 2022: 15 · 2021: 17 · 2020: 13 · 2019: 3
- FWCI
- 5.11
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Nottingham ePrints (University of Nottingham) (acceptedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Keywords
- synchronverter, LCL filter, robust stability, structured singular value analysis, mu-synthesis, grid conditions, small-signal linearization, controller tuning, power hardware-in-the-loop, grid-forming inverters, multivariable control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review