Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 192

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Controller-Embeddable Probabilistic Real-Time Digital Twins for Power Electronic Converter Diagnostics

Milton, Matthew, De La O, Castulo, Ginn, Herbert L., Benigni, Andrea · 2020 · IEEE Transactions on Power Electronics

Abstract

In this article, an approach is proposed for the online diagnostic analysis of power electronic converters utilizing real-time, probabilistic digital twinning. Under this approach, a digital twin (DT) of a power converter is defined as a real-time, probabilistic simulation model with stochastic (random) variables, developed using generalized polynomial chaos expansion. The DT models are partitioned in perspective of control layers for power converter subsystems in the approach, with emphasis on the application and converter control layers. Real-time executed solvers of these divided probabilistic DT models are embedded into power converter controllers running on field programmable gate array (FPGA) computing devices. Using a monitoring system, the real-time probabilistic DTs at each control layer and the corresponding physical twins of the power converter are compared by the controllers to determine if the power converter is operating within probable behavior. Knowing the large computational cost of probabilistic modeling, the resource usage and timing of real-time DT solvers on modern FPGAs is reported for common power electronic converter topologies, showing the approach is feasible and able to perform probabilistic real-time simulation of smaller power converters in perspective of application and converter control layers using ≤2 μs time steps, with as low as 70 ns steps; while staying embeddable within FPGA-based controllers. To highlight the capabilities of the proposed approach, a case study is presented using a probabilistic DT in the application layer controller of a pair of converters to comparatively monitor their behavior and corresponding controller action under hardware-in-the-loop testing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tpel.2020.2971775

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 192

Metadata

Authors
Milton, M., De La O, C., Ginn, H. L., & Benigni, A.
Venue
IEEE Transactions on Power Electronics
Published
2020-09
Volume
35
Issue
9
Pages
9850-9864
ISSN
  • 0885-8993 (ISSN-L)
  • 1941-0107
OpenAlex
W3005058934
Cited by
192
References
3
FWCI
13.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Controller-Embeddable Probabilistic Real-Time Digital Twins for Power Electronic Converter Diagnostics. https://app.cochat.ai/papers/10.1109/tpel.2020.2971775
The paper
Milton, M., De La O, C., Ginn, H. L., & Benigni, A. (2020). Controller-Embeddable Probabilistic Real-Time Digital Twins for Power Electronic Converter Diagnostics. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2020.2971775

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.