Design and Performance of the 850-V 100-kW 16-kHz Bidirectional Isolated DC–DC Converter Using SiC-MOSFET/SBD H-Bridge Modules
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This article designs, builds, and tests the 850-V 100-kW 16-kHz bidirectional isolated dc-dc converter using the latest 1.2-kV 400-A SiC-MOSFET/SBD H-bridge modules, with focus on efficiency improvement. Here, SBD stands for Schottky barrier diode. It proposes intermittent operation with continuous-current mode (CCM), to reduce switching losses in partial loads. Experimental results verify that the conversion efficiency from the dc input to the dc output is as high as 99.3% at the rated power of 100 kW, and 99.2% at a partial load of 10 kW. These are measured and calculated, discarding auxiliary power losses of 82W in total, which are produced by the digital controller, gate-drive circuits, and cooling fans. Experimental transient waveforms show that no dc magnetic flux is included in the 850-V 100-kW 16-kHz transformer at intervals of switchover between the continuous operation and the CCM intermittent operation when power reversal from -100 to 100 kW is performed at an interval of 1 ms. Finally, this article presents an experimental and theoretical discussion on the voltage ripples appearing across the dc capacitor of each bridge.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solid-State Transformer Architecture Using AC–AC Dual-Active-Bridge Converter
Qin, H., & Kimball, J. W. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2204710 · Cited by 310
Cited by
Soft-Switching Solid-State Transformer With Reduced Conduction Loss
Zheng, L., Kandula, R. P., & Divan, D. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3030795 · Cited by 105
Zheng, L., Kandula, R. P., & Divan, D. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3101482 · Cited by 85
SiC-Based Power Electronic Traction Transformer (PETT) for 3 kV DC Rail Traction
Adamowicz, M., & Szewczyk, J. (2020) · Energies · doi:10.3390/en13215573 · Cited by 24
“However, in some justified cases, the use of additional auxiliary inductance may be unavoidable [33].”
Background
Metadata
- Authors
- Haneda, R., & Akagi, H.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2020-10
- Volume
- 35
- Issue
- 10
- Pages
- 10013-10025
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W3008652617
- Cited by
- 62
- References
- 1
- FWCI
- 3.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and Performance of the 850-V 100-kW 16-kHz Bidirectional Isolated DC–DC Converter Using SiC-MOSFET/SBD H-Bridge Modules. https://app.cochat.ai/papers/10.1109/tpel.2020.2975256
- The paper
- Haneda, R., & Akagi, H. (2020). Design and Performance of the 850-V 100-kW 16-kHz Bidirectional Isolated DC–DC Converter Using SiC-MOSFET/SBD H-Bridge Modules. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2020.2975256
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.