A Review of DC Shipboard Microgrids—Part II: Control Architectures, Stability Analysis, and Protection Schemes
Open accessThe DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Abstract
This article presents a review of coordinated control strategies, stability analysis, and fault management for dc shipboard microgrids (dc-SMGs). As an emerging application, the dc-SMG lacks a comprehensive summary of the control schemes. Considering the specific load profile in ships, this article discusses the coordinated control strategies of diesel generators and energy storage system. Depending on the maritime conditions, different operation modes are switched by the energy management system. Due to the presence of high-bandwidth controlled constant power load converters, negative impedance instability is induced. Meanwhile, the pulsed loads in dc-SMG may affect the voltage stability significantly. Small-signal and large-signal stability analysis can be used to evaluate the effect of these two types of loads. In the aspect of the shipboard protection system, this article presents the specific requirements of dc-SMG based on the standards. Lacking “ground” in ships, solutions in designing the grounding system for dc-SMG is described. Besides, the short-circuit fault management consisting of fault detection, fault isolation, and reconfiguration in dc-SMGs are summarized. Finally, the existing commercial dc ships are presented and compared to demonstrate the developing trends.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DC Microgrids–Part I: A Review of Control Strategies and Stabilization Techniques
Dragicevic, T., Lu, X., Vasquez, J., & Guerrero, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2478859 · Cited by 1,564 · cited 1×
“The overview of control strategies for general dc MGs is presented in [10]–[12].”
BackgroundSelf-citationAnand, S., Fernandes, B. G., & Guerrero, J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2215055 · Cited by 920 · cited 1×
“The overview of control strategies for general dc MGs is presented in [10]–[12].”
BackgroundSelf-citationDynamic Behavior and Stabilization of DC Microgrids With Instantaneous Constant-Power Loads
Kwasinski, A., & Onwuchekwa, C. N. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2091285 · Cited by 626 · cited 1×
“different interface converters into account, the stability analysis should be extended [67].”
BackgroundReview on Control of DC Microgrids
Meng, L., Shafiee, Q., Ferrari Trecate, G., Karimi, H., Fulwani, D., Lu, X., & Guerrero, J. M. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2690219 · Cited by 513 · cited 1×
“The overview of control strategies for general DC MGs is presented in [10], [11], [12].”
BackgroundSelf-citationDC Microgrid Protection: A Comprehensive Review
Beheshtaein, S., Cuzner, R. M., Forouzesh, M., Savaghebi, M., & Guerrero, J. M. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2904588 · Cited by 365 · cited 1×
“On the other hand, due to the presence of pulsed loads, conventional dc MGs fault detection approaches presented in [21]–[23] have to be modified to fit the”
BackgroundSelf-citationWang, P., Lu, X., Yang, X., Wang, W., & Xu, D. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2499310 · Cited by 364 · cited 1×
“4(b) are presented in [45], and this figure presents the decentralized control method as an example.”
MethodOptimal Reconfiguration of Radial Distribution Systems to Maximize Loadability
Venkatesh, B., Ranjan, R., & Gooi, H. B. (2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2003.818739 · Cited by 348
Stability Enhancement Based on Virtual Impedance for DC Microgrids With Constant Power Loads
Lu, X., Sun, K., Guerrero, J. M., Vásquez, J. C., Huang, L., & Wang, J. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2455017 · Cited by 328 · cited 1×
“less damped and affecting stability [71].”
Self-citationModeling and Stability Analysis of Islanded DC Microgrids Under Droop Control
Tahim, A. P. N., Pagano, D. J., Lenz, E., & Stramosk, V. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2360171 · Cited by 326 · cited 1×
“The impacts of CPL on general MGs have been widely studied [70].”
BackgroundLi, W., Monti, A., & Ponci, F. (2014) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2014.2313035 · Cited by 294 · cited 1×
“Operation Advantages Limitation Overcurrent protection [129], [130], [131] Triggers the relays when the current exceeds the predefined threshold within several ms. WT-based method [133], [134] Extracts the signal feature of fault current in time and frequency domain.”
Method
Cited by
New Horizons for Microgrids: From Rural Electrification to Space Applications
Micallef, A., Guerrero, J. M., & Vasquez, J. C. (2023) · Energies · doi:10.3390/en16041966 · Cited by 31
Self-citation
Metadata
- Authors
- Xu, L., Guerrero, J., Lashab, A., Wei, B., Bazmohammadi, N., Vasquez, J., & Abusorrah, A.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2022-04
- Volume
- 37
- Issue
- 4
- Pages
- 4105-4120
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W3211813355
- Cited by
- 170
- References
- 72
- FWCI
- 11.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.