High-Frequency Transformer Design With Medium-Voltage Insulation for Resonant Converter in Solid-State Transformer
The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
A solid-state transformer can directly convert medium voltage to low voltage (e.g., 400 V) with minimized power-conversion stages. The transformer in the dc–dc module not only provides medium-voltage insulation but also significantly affects the power density of the module. In this article, an innovative compact transformer structure is proposed to handle medium-voltage insulation using an insulation coordination with epoxy, bobbin, shielding layer, and stress-control layer. A brand-new bobbin design and related fabrication process ensures a partial-discharge-free insulation. Besides the traditional core loss and winding loss, high-frequency-related core loss and shielding loss are modeled in detail for the accurate loss evaluation. A simple and comprehensive multiparameter, multiobjective optimization process is proposed to achieve the size and loss tradeoff. The transformer prototype passes the related insulation tests, following the standard IEEE Std. C57.12.01. Finally, the design is demonstrated on a 15 kW, 200 kHzCLLCconverter with 98.9% peak efficiency and 3.8 kW/L power density.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
DC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
Review of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164
Voltage and Power Balance Control for a Cascaded H-Bridge Converter-Based Solid-State Transformer
Zhao, T., Wang, G., Bhattacharya, S., & Huang, A. Q. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2216549 · Cited by 642 · cited 4×
“The authors in [16], [38], and [39] operate the dc–dc converter with dual active bridge (DAB) at tens of kilohertz.”
BackgroundMethodInfluentialPartial discharges. Their mechanism, detection and measurement
Bartnikas, R. (2002) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2002.1038663 · Cited by 569
Optimal choice for number of strands in a litz-wire transformer winding
Sullivan, C. R. (1999) · IEEE Transactions on Power Electronics · doi:10.1109/63.750181 · Cited by 558
Fei, C., Lee, F. C., & Li, Q. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2674599 · Cited by 510
Self-citationEvaluation of 400V DC distribution in telco and data centers to improve energy efficiency
Pratt, A., Kumar, P., & Aldridge, T. V. (2007) · INTELEC 07 - 29th International Telecommunications Energy Conference · doi:10.1109/intlec.2007.4448733 · Cited by 415
Chanda, M., & Roy, S. K. (2006) · CRC Press eBooks · doi:10.1201/9781420006360 · Cited by 386
99% Efficient 10 kV SiC-Based 7 kV/400 V DC Transformer for Future Data Centers
Rothmund, D., Guillod, T., Bortis, D., & Kolar, J. W. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2886139 · Cited by 315
100 kW, 10 kHz Medium-Frequency Transformer Design Optimization and Experimental Verification
Mogorovic, M., & Dujic, D. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2835564 · Cited by 274
Research works printed but not linked: 1
- 2000, High-voltage test techniques – Partial discharge measurements
Cited by
Cao, Y., Ngo, K. D. T., & Dong, D. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3279259 · Cited by 67
“W ITH the development of electrical vehicle (EV) charging system [1], [2], [3], energy storage system (ESS) [4], [5], [6], data center power supply [7], [8], [9], and solid-state”
BackgroundA Three-Level Buck–Boost Converter With Planar Coupled Inductor and Common-Mode Noise Suppression
Cao, Y., Bai, Y., Mitrovic, V., Fan, B., Dong, D., Burgos, R. P., Boroyevich, D., Moorthy, R. S. K., & Chinthavali, M. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3279987 · Cited by 53
Jin, F., Nabih, A., Yuan, T., & Li, Q. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3354679 · Cited by 64
“Dual active bridge (DAB) [18], [19] or CLLC converter [6], [20], [21], [22], [23], [24], [25] are good topology candidates for bidirectional applications over LLC [26], [27], [28], [41] converter as they have a symmetrical voltage gain range.”
BackgroundSelf-citationSong, Y.-H., Yin, L., Zhong, S., Feng, Q., Wang, H., Zhang, P., Xu, H., Tong, L., & Dang, Z. (2024) · Advanced Composites and Hybrid Materials · doi:10.1007/s42114-024-00914-6 · Cited by 44
Zhang, R., Garcia, R., Strittmatter, R., Zhang, Y., & Zhang, S. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3290117 · Cited by 32
Liu, J., Motwani, J. K., Burgos, R. P., Zhou, Z., & Dong, D. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3283469 · Cited by 26
“Second, compared to the modular concepts with MV isolation requirement, the centralized transformer occupies smaller amount of space [17], [18].”
BackgroundIntegrated Inductor-Transformers for High-Frequency Converters: An Overview
Wouters, H., & Martinez, W. H. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3569420 · Cited by 28
Cao, Y., & Dong, D. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3295130 · Cited by 18
Jin, F., Yuan, T., Nabih, A., & Li, Q. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3436044 · Cited by 21
“Dual active bridge (DAB) [9], [10] and CLLC converter [2], [5], [11], [12], [13], [14], [15] are good topology candidates for bidirectional applications over LLC [16], [17], [18], [19], [20] converter as they have a symmetrical voltage gain range.”
Self-citationOptimization Design of High-Frequency Matrix Transformer for Solid-State Transformer
Wan, Z., Li, Y., Wang, H., & Li, X. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3424509 · Cited by 16
“A 15 kW, 200 kHz HFT is developed in [27].”
BackgroundPartial Discharge Characteristics of Epoxy Resin Under High-Frequency Pulse Electrical Stress
Jiang, J., Cui, D., Liu, J., Chen, B., Chen, J., & Fu, R. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3421624 · Cited by 16
“[4].”
Cao, Y., Ngo, K. D. T., & Dong, D. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3392579 · Cited by 12
“…and high-power dc transformers (DCXs) is being propelled by the rapid development of energy storage systems in renewable energy [1], [2], [3], [4], [5], [6], [7], [8], microgrids [9], [10], [11], The authors are with the Center for Power Electronics Systems, Virginia Polytechnic…”
BackgroundBa, D., Yu, F., Wang, Y. S., Chen, X., Niu, Y., & Lyu, X. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3581515 · Cited by 14
“Therefore, ensuring the consistency and reliability of high-frequency PCB transformers during long-term operation is crucial in high-frequency applications [13].”
Interactions Analysis and Life Modeling for High-Frequency Transformers Insulation Under Multistress
Wang, Z., Wei, X., da Silva, F. F., Sørensen, H., Shen, Z., & Bak, C. L. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3520336 · Cited by 12
“I N the past decade, solid-state transformers (SSTs) have re- ceivedconsiderableattentionandhavebeenextensivelystud-ied for applications in distribution systems, renewable energy collection, and fast-charging stations [1], [2], [3], [4].”
Partial Discharge Behavior of High-Frequency Transformer Insulation Under High-Voltage PWM Stress
Wang, Z., Wei, X., Bak, C. L., da Silva, F. F., Luo, T., Zhao, W., Vaessen, P., Sørensen, H., & Niasar, M. G. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3566999 · Cited by 15
“1109/TPEL.2025.3566999 electronic converters [1], [2], [3].”
InfluentialDesign and Optimization with Litz Wire Version of PCB in Solid-State Transformer
Li, Z., Feng, J., Lou, X. N., Li, Y.-H. H. Q., & Lee, F. C. (2024) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec48139.2024.10509347 · Cited by 13
Self-citationSolid-State Transformers: A Review—Part II: Modularity and Applications
Predescu, D.-M., & Rosu, S. G. (2025) · Technologies · doi:10.3390/technologies13020050 · Cited by 15
“…proposed in multiport applications, where each individual interconnected cell has its individual output port, thus allowing multiple low-voltage consumers to interface with a high-voltage supply [103] or for distributed renewable sources with low voltages to connect to a high-voltage grid [104].”
Winding Loss Analysis of PCB Winding Litz Wire
Xiang, Z., Li, Z., Bae, J.-S., et al. (2024) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce55643.2024.10861356 · Cited by 9
Self-citationSolid State Transformers: A Review—Part I: Stages of Conversion and Topologies
Predescu, D.-M., & Rosu, S. G. (2025) · Technologies · doi:10.3390/technologies13020074 · Cited by 17
“…fields (energy transmission [1,2], storage [3], charging stations/onboard chargers [4–7], HVDC [8,9], renewable energy [10–12], electric transportation [13,14], and telecommunications [15]) has given rise to research into new ways to change voltage levels, especially at higher power levels.”
Feng, J., Li, Z., Yuan, T., Zhao, C., & Li, Q. (2024) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec48139.2024.10509429 · Cited by 11
“The converter has fixed-ratio of input and output voltage, namely dc transformer (DCX), has gained popularity [20-21] [28-29].”
BackgroundSelf-citationQin, L., Wu, T., Xiao, Y., Li, L., & Guan, Y. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3454100 · Cited by 10
“Moreover, theinput-series-output-parallel(ISOP)dualactivebridge(DAB) converterisanimportantstructurefordctransformer,realizing interconnectionbetweenmedium-voltage(MV)busandlow-voltage(LV)bus[3],[4],[5].”
A high voltage gain solid-state transformer for integration of renewable energy and AC sources
Hashemzadeh, S. M., Al-Hitmi, M. A. E., Islam, S., Iqbal, A., Aghaei, H., Hosseini, S. H., & Babaei, E. (2024) · Scientific Reports · doi:10.1038/s41598-024-77326-5 · Cited by 12
Partial Fluctuation Power Control of Resonant Converter in Solid-State Transformer
Li, Z., Zhao, C., Hsieh, Y. L., Li, Q., & Lee, F. C. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2023.3347828 · Cited by 10
“Compared to the conventional solutions, the SST has a smaller volume and footprint [3], [4], [5], [6].”
BackgroundSelf-citationAssessment of Dielectric Strength for 3D Printed Solid Materials in Terms of Insulation Coordination
Uydur, C. C. (2024) · Applied Sciences · doi:10.3390/app142411860 · Cited by 7
Budiwicaksana, L. A., & Lee, D. (2024) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2024.3386948 · Cited by 9
“Operation of high-power dc/dc converters has been extensively studied up to 500 kHz of switching frequency [30], [31], [32].”
BackgroundDesign and Testing of a Soft-Switching Solid-State Transformer Module
Ren, X., Jiang, Y., Weng, H., Long, T., & Xu, D. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2024.3447455 · Cited by 9
“The MFT needs to provide MV galvanic isolation, which poses a significant constraint on shrinking the volume and causing extra losses [16], [17], [18].”
Dang, Y., Zhu, L., Liu, F., Zhang, F., Liu, Z., & Ji, S. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3521456 · Cited by 7
“First, the maximum temperature rise limits the ideal power density and power ef-ficiency of HFTs [11], [2], [12], [13], [14].”
A Transformer Design with PCB Litz Wire Concept for Solid State Transformer
Li, Z., Feng, J., Lou, X., Hsieh, Y.-H., Li, Q., & Lee, F. C. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362376 · Cited by 9
Self-citationCyber Resiliency of a Solid-State Power Substation
Gupta, S., Greidanus, M. D. R., D’silva, S., Bhattacharya, S., Mazumder, S. K., Shadmand, M. B., Govindarasu, M., Kim, T., Balda, J. C., Song, X., et al. (2024) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec48139.2024.10509048 · Cited by 6
Lu, R., Li, C., Yu, J., et al. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3313960 · Cited by 5
“As the core component of the MVSST, the medium voltage high-frequency transformer (MVHFT) with high power density not only needs to efficiently transmit energy but also must ensure high insulation levels [2], [3].”
BackgroundCao, Y., & Dong, D. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362177 · Cited by 5
“…(DCX), has gained widespread adoption in response to the development of various dc power systems [1]-[5] such as electrical vehicle (EV) charging system [6]- [10], energy storage system (ESS) [11]-[15], data center power supply [16]-[18], and solid-state transformer (SST) system [19]-[24].”
BackgroundDai, X., Hao, J., Liao, R., & Bak, C. L. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3583170 · Cited by 5
Gao, Z., Li, D., Chen, R., et al. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362890 · Cited by 5
“In [14], dry-type insulation has been used to achieve the partial discharge (PD) free insulation required for 4.16 kV.”
MethodInfluentialA Highly Modular Interphase Solid-State Transformer Architecture
França, J. V. G., Costa, L. F., & Papafotiou, G. A. (2025) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce58356.2025.11259843 · Cited by 6
“2 (a) illustrates the CHB-based SST, which various authors have investigated [14]–[16].”
Guo, Z.-C., Cao, B., Chen, C., & Huang, A. Q. (2026) · IEEE transactions on power electronics · doi:10.1109/tpel.2026.3654531 · Cited by 6
“For a data center application, a 15 kW/200 kHz HFT-based SST has been developed for an input 4.16 kV ac/ output 400V dc data center power solution [45].”
InfluentialComparative Analysis of CHB and MMC-Based Solid-State Transformer Architectures
França, J. V. G., & Costa, L. F. (2025) · IEEE International Conference on Compatibility, Power Electronics and Power Engineering · doi:10.1109/cpe-powereng63314.2025.11027220 · Cited by 7
“The main advantages of this configuration are the lower complexity and fewer submodules compared to MMCs [20], [21].”
Liu, Z., Zhu, L., Dang, Y., & Ji, S. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3610516 · Cited by 5
“Accurate estimation of core loss is significant for accurate temperature prediction and reliable thermal design of HFT [9], [11], [12], [13].”
PCB Based Inductor Structure for MV Applications
Anurag, A., & Barbosa, P. M. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3334156 · Cited by 4
“In [3], a PCB winding based transformer is demonstrated.”
Jin, F., Zhao, C., Yuan, T., & Li, Q. (2024) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec48139.2024.10509185 · Cited by 4
“Isolated converters like the LLC converter, CLLC converter, series resonant converter, etc, are widely used in many applications, including data centers [10-11], telecom, electric vehicles (EVs) applications [13-16], solid-state transformer applications [18-19], railway applications [22-24].”
BackgroundSelf-citationChen, C., Guo, Z., & Huang, A. Q. (2024) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec48139.2024.10509302 · Cited by 5
“Many existing high insulation PCB-winding transformer designs applied conductive or semi-conductive coating on the PCB surface to limit the electric field in the air near PCB [12], [15].”
BackgroundPartial Discharge Test of High-frequency Transformers with Plastic Mold for SST
Yonetomi, R., Kusaka, K., Koike, N., & Nagai, S. (2024) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia60879.2024.10567600 · Cited by 6
“Thus, molded transformers can be smaller and lighter than conventional transformers, such as oil-filled transformers, and require less maintenance [4].”
BackgroundA Novel Linear-Based Closed-Loop Control and Analysis of Solid-State Transformer
Çavdar, M., & Ozkilic, S. O. (2024) · Electronics · doi:10.3390/electronics13163253 · Cited by 4
Heat Extraction from Ferrite Cores Using Metallic Laminations
Brown, A., Nguyen, D. T., & Hanson, A. J. (2025) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec48143.2025.10977461 · Cited by 5
A Comparative Evaluation between Hybrid Modular Multi-Level Converters and Alternate Arm Converter
Motwani, J. K., Liu, J., Boroyevich, D., Burgos, R. P., & Dong, D. (2023) · IEEE ... Workshop on Control and Modeling for Power Electronics · doi:10.1109/compel52896.2023.10221032 · Cited by 5
“Maintaining modularity and scalability while still considering power-density and lower cost has thus been a key motivator for many recent research efforts [7]–[9].”
ResultSubramanian, N., & Stonier, A. A. (2025) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2025.3635099 · Cited by 3
“In order to support condition monitoring and reliability enhancement, advanced imaging tools like microscopy, spectroscopy, and PD imaging allow for high-resolution diagnostics of structural flaws, moisture ingress, and insulation aging [103], [104], [105].”
InfluentialImproved Oscillation Method for High-Frequency Magnetic Core Loss Measurement
Xiang, D., Sun, Z., Li, H., Hu, H., Zhong, H., & Lu, G. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3472121 · Cited by 3
“Therefore,accurate [5],[6],[7], [8], [9], [10].”
PD-Free Design of Insulation Systems: An Application to Laminated Busbars
Montanari, G. C., & Cambareri, P. (2024) · Applied Sciences · doi:10.3390/app142210171 · Cited by 3
Adhikari, B., & Ghassemi, M. (2025) · IEEE Kansas Power and Energy Conference (KPEC) · doi:10.1109/kpec65465.2025.11045007 · Cited by 10
“The insulation coordination using epoxy, bobbin, shielding layer, and stress-control layer, ensuring PD-free insulation, is proposed in [41].”
A High Power High Isolation Medium Frequency Transformer With A Planar Matrix Structure
Guo, Z., Chen, C., Chen, Z., & Huang, A. Q. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362495 · Cited by 4
Sharfeldden, S., Moaz, T., Rajagopal, N., Lawson, M. A., & DiMarino, C. (2024) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec48139.2024.10509039 · Cited by 3
“In [11], a CLLC-based SST for dc-dc power conversion, achieving 15 kW at 200 kHz with 98.6% efficiency was achieved.”
MethodInfluentialSymmetrical Transformer for Medium-Voltage Medium-Frequency ISOP Three-Phase LLC SST
Mirzadarani, R., Li, Z., Qin, Z., et al. (2024) · doi:10.1109/ipemc-ecceasia60879.2024.10567857 · Cited by 3
Self-citationUydur, C. C., & Akın, F. (2024) · Applied Sciences · doi:10.3390/app142411894 · Cited by 2
A Pseudobinary Cascaded H-Bridge Converter for the Front-End Stage of Solid-State Transformers
Gutierrez, B., Hou, Z., & Lai, J. (2025) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2025.3595963 · Cited by 2
“The DAB operates with zero voltage switching (ZVS) over a wide load range, but its high secondary-side turn-OFF losses can limit ef fi ciency and miniaturization intention [10].”
Liu, Z., Zhou, G., He, Y., et al. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3642890 · Cited by 2
“Ulteriorly, by adding converter efficiency as a constraint, the Pareto Front of the coupled inductor volume and converter efficiency is studied [22], [23], [24].”
Deng, Z., Zhang, S., Zhu, G., et al. (2026) · IEEE Journal on Wireless Power Technologies · doi:10.1109/jwpt.2026.3670766 · Cited by 2
“Although these extra transformers are introduced, their impact on overall ef fi - ciency is minimal, as the ef fi ciency of high-frequency transformers can easily reach approximately 99 % [45].”
Wang, Z., da Silva, F. F., Sørensen, H., Wang, Q., & Bak, C. L. (2023) · IEEE International Power Electronics and Application Symposium (PEAS) · doi:10.1109/peas58692.2023.10395853 · Cited by 3
“With the increasing voltage level of high power semiconductor devices, power electronic transformers (PETs) gained widespread application in medium voltage DC distribution, renewable energy collection, and fast charging stations [1, 2, 3].”
BackgroundYi, Z., Liu, Z., Sun, K., & Su, B. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2024.3407846 · Cited by 2
Qi, T., Ren, H., Gao, H., et al. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3485397 · Cited by 2
“Nevertheless, the performance of electrical insulation is a crucial concern that restricts the development of power electronic devices and equipment toward high voltage, high power, and miniaturization [6], [7], [8].”
BackgroundSelf-citationLu, S., Xu, S., Deng, J., Li, T., Li, S., Xia, J., & Zhao, D. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3522589 · Cited by 3
“Previous studies [13], [38] have provide a way to increase the output power using the split windings, and the results in [38] show that by splitting the windings into symmetric multiwinding structure and connecting each of the windings to a power converter, there are no current sharing issues…”
A High-Power MVAC-LVDC Rectifier Empowering Wide Voltage Range Operation
Wang, N., Li, B., Wang, Y., Jiao, Y., Deng, F., Li, R., & Xu, D. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3528236 · Cited by 2
“Thus, a larger safety margin should be applied to the insulation of transformers, which results in higher insulation overhead and higher cost per power [34], [35].”
Song, H., Stewart, J., Barzkar, A., Fan, B., Burgos, R. P., & Boroyevich, D. (2024) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce55643.2024.10861321 · Cited by 2
Deng, S., Cheng, S., Zhang, X., Cao, X., Wang, C., Wang, Z., Yang, F., Guo, H., & Zhao, H. (2024) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias55788.2024.11023828 · Cited by 2
Yi, Z., Sun, K., Dang, Z., Song, Y., & Liu, Z. (2023) · IEEE PELS Students and Young Professionals Symposium (SYPS) · doi:10.1109/syps59767.2023.10268157 · Cited by 3
“The isolated DC-DC converters in the SST system are connected in series or in parallel to reach the desired voltage step-up or stepdown ratio, which greatly affects voltage insulation, leading to the insulation design significantly affecting the reliability of the SST as well as the distribution system[4][5].”
BackgroundA Study High Voltage PCB Litz Wire Concept for Solid-State Transformer
Hsu, C., & Chen, J. F. (2024) · International Conference on Renewable Energy Research and Applications (ICRERA) · doi:10.1109/icrera62673.2024.10815300 · Cited by 2
Investigating the short-circuit endurance of 220 kV transformer in a 400 kV grid system
Kotta, N., & Nakka, J. (2025) · International Journal of Emerging Electric Power Systems · doi:10.1515/ijeeps-2024-0304 · Cited by 1
Dang, Y., Zhu, L., Liu, F., Li, S., Liu, Z., & Ji, S. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3570986 · Cited by 1
Enhancing Breakdown Strength of Silicone Rubber Insulating Composite for High‐Frequency Transformers
Tong, L., Song, Y., Zhang, Y., et al. (2025) · Polymer Composites · doi:10.1002/pc.70372 · Cited by 1
Bhattacharjee, B., Mukherjee, S., Bhattacharjee, R., Bhattacharya, S., Ganguly, A., & Das, A. (2025) · Facta universitatis - series Electronics and Energetics · doi:10.2298/fuee2503469b · Cited by 1
Zhang, P., Li, P., Li, X., et al. (2026) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2026.111596 · Cited by 1
Thermal Design, Modeling, and Evaluation of Liquid-cooling High-power Planar Transformer
Liu, H., & Sun, K. (2026) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2026.3658201 · Cited by 1
“In practice, thermal design is just as important as electrical and magnetic design [3], [4], [5], [6], [7].”
Mirzadarani, R., Li, Z., Qin, Z., Vaessen, P., Bauer, P., & Niasar, M. G. (2026) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2026.3665278 · Cited by 1
“Field grading and insulation design in SST applications are the subject of several studies [12], [13], [14], [15], [16], [17], [18].”
Self-citationNoh, E., So, J., Park, J.-H., & Lee, S.-H. (2026) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2026.3663785 · Cited by 3
“This configuration effectively leverages the high dielectric strength of epoxy to ensure reliable insulation performance under high-voltage conditions [36].”
Flatwise Windings for Improved Thermal Management in High Power Transformer Applications
Roque, K. R., Masuda, I., Choi, S., Imaoka, J., Yamamoto, M., Kauhanen, M., & Tashiro, K. (2026) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec51134.2026.11516701 · Cited by 1
“One category of solutions focuses on improving thermal extraction from within the transformer itself using methods like dry casting [2], encapsulation [3], or oil immersion [4], which can concurrently enhance insulation capabilities.”
Gao, Z., Chen, R., Li, D., et al. (2023) · doi:10.1109/wipda58524.2023.10382201 · Cited by 1
Cao, Y., Ngo, K. D. T., & Dong, D. (2024) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec48139.2024.10509350 · Cited by 1
“bridge (DAB) [27] and the LLC/CLLC series resonant converter (SRC) [9], [28] – [32], LLC/CLLC-DCX is more desirable because it has a lower circulating current and full zero voltage switching (ZVS).”
BackgroundHan, J., Li, X., & Tang, T. (2024) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.4140 · Cited by 1
Kamalapur, A., Bae, J.-S., Cairnie, M., et al. (2025) · IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec48143.2025.10977500 · Cited by 1
“…can be cascaded to achieve the desired conversion ratio, V /V for each cell. non-linear insulation requirements introduce significant challenges in the design of high-frequency transformers (HFTs) within individual SST cells, reducing the achievable power density to as low as 3.8 MW / m 3 [3].”
InfluentialSelf-citationZhou, H., Yu, X., Xu, W., et al. (2025) · Energies · doi:10.3390/en18154196 · Cited by 1
Lu, R., Yao, Y., Zheng, C., Yu, J., Li, C., & Li, W. (2023) · IEEE International Power Electronics and Application Symposium (PEAS) · doi:10.1109/peas58692.2023.10395784 · Cited by 1
“As the only isolation component in the MVSST system, the medium voltage high-frequency transformer (MVHFT) needs to achieve highly efficient power transfer and high-frequency isolation under high power density [4]-[7].”
BackgroundLoss-Optimized Design of Magnetic Devices
Zhao, Y., Ming, Z., & Du, C. (2024) · Micromachines · doi:10.3390/mi15060697
“Therefore, we took into account the porosity parameter of the winding layers and corrected Ferreira’s method [34,41].”
MethodYavuzdeğer, A., Esenboğa, B., & Demirdelen, T. (2024) · Çukurova Üniversitesi Mühendislik Fakültesi Dergisi · doi:10.21605/cukurovaumfd.1559912
Study of Overmodulation of Solid-State Transformer Under Asymmetric Grid Short-Circuit Faults
Zheng, H., Lin, Q., Burgos, R. P., Dong, D., & Li, X. (2024) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce55643.2024.10861646
Matrix-Based Inductor Structure for MV Applications
Anurag, A., Wang, R., & Barbosa, P. M. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3554391
“In [5] and [6], PCB winding-based transformers are demonstrated.”
Budiwicaksana, L. A., & Lee, D. (2025) · Journal of Power Electronics · doi:10.1007/s43236-025-01042-0 · Cited by 1
“The minimum and maximum frequency are chosen to be 25 kHz and 33 kHz to limit the core loss, skin effects, and insulation problems [26].”
Liu, Z., Zhu, L., Gao, Y., Dang, Y., Zhan, C., & Ji, S. (2025) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec48143.2025.10977242
“To ensure the insulation safety of HFT and meanwhile the HFT size, epoxy resin potting schemes [11], [12] are usually adopted for high-voltage HFTs.”
Research on equivalent circuit of transformer based on reply voltage method
Hu, J., Chen, T., Wang, H., et al. (2025) · Journal of Physics Conference Series · doi:10.1088/1742-6596/3033/1/012042
An Isolated Multiport Modular Multilevel DC-DC Converter for Electric Vehicle Fast-Charging Station
Rasouli, M., & Wei, Q. (2025) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg62294.2025.11060437
“Furthermore, each HFT in this structure requires insulation rated at input MV voltage due to the modularity, increasing the system's size and bringing HFT designing challenges [5], [6].”
Current Balancing Technique for the High-Current Windings of Medium-Frequency Transformers
Mirzadarani, R., Li, Z., Qin, Z., Vaessen, P., Bauer, P., & Niasar, M. G. (2025) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2025.3618838 · Cited by 1
“Prior research has explored various aspects of SST design, including their efficiency, thermal management, and electromagnetic performance [8], [16], [17], [18], [19], [20], [21], [22], [23].”
Self-citationDeng, S., Cheng, S., Zhang, X., Cao, X., Wang, C., Wang, Z., Guo, H., Yang, F., Zhan, Y., Xu, G., et al. (2025) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2025.3635594 · Cited by 1
“A S A highly controllable novel power conversion device, the power electronic transformer (PET) can meet the requirements of high power density and light weight for photo-voltaic integration and offshore wind power connected to smart grids [1], [2].”
Design and Development of 3/2-Level DAB SiC Converter for SST Applications
Nasir, U., Rasekh, N., Bowkett, M., Johnson-Brett, A., Wei, J. D., Ali, A., Akbar, U., Calderon-Lopez, G., & Lüdtke, I. (2025) · Energy Conversion Congress and Expo Europe (ECCE Europe) · doi:10.1109/ecce-europe62795.2025.11238456
“The standard DC/DC stage topology is a Two-Level (2L) DAB, however, replacing a domestic distribution 11 kV to 400 V line-frequency transformer with a SST would require [9].”
Insulation Coordination for Direct MV Connected Power Converters
Özdemir, Ş., Altın, N., & Nasiri, A. (2025) · International Conference on Renewable Energy Research and Applications (ICRERA) · doi:10.1109/icrera66237.2025.11284250
“The insulation coordination of high-frequency transformers represents a complex and critical aspect of design that demands dedicated and specialized investigation [14].”
Lee, S., Kwon, M., Lee, J., & Cha, H. (2026) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2025.3633730
An Efficient LCL-T -Based Compact Resonant Converter for On-Board Charger
Deo, A., & Verma, A. K. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3643182
“Nonetheless, inadequate conductivity in dielectric materials and parasitic capacitance may result in suboptimal thermal performance, while reduced isolation thickness might exacerbate parasitic capacitance [16].”
Single Stage Soft Switched Medium Voltage AC to DC Converter With Reduced Current Stress
Harisyam, P. V., Mazumder, S., Saichand, K., Mathapati, S., & Basu, K. (2026) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2026.3655645
“To achieve medium-voltage insulation between the AC-side winding, DC-side winding, and the magnetic core, the high-frequency transformer must be specifically designed with appropriate insulation strategies, as discussed in [56], [57], [58], [59].”
Elrajoubi, A. M., & Alshawish, A. M. (2024) · مجلة البحوث الأكاديمية · doi:10.65540/jar.v28i2.714
Liu, Z., Zhu, L., Zhang, G., Dang, Y., Zhang, S., & Ji, S. (2026) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2026.3666301 · Cited by 1
“In [6] and [7], natural air cooling is used for HFT cooling.”
High-Efficiency Stress-Annealed Nanocrystalline Transformer for PWM Converters
Ren, S., Jiang, C., Chen, C., Wang, Y., Wei, S., Yang, F., & Long, T. (2026) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2026.3666883
Voltage Stability Analysis of Multi-Port Power Router
Liang, W., Chen, J., Liu, M., Li, Q., Zhong, W., & Abdukalykovich, K. U. (2025) · International Academic Exchange Conference on Science and Technology Innovation (IAECST) · doi:10.1109/iaecst68792.2025.11415002
Self-citationChen, C., Kim, C., Zhang, M., & Huang, A. Q. (2026) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2026.3677638
Wang, L., Wang, X., & Song, W. (2026) · International Conference on Power Electronics and Electric Drives (PEED) · doi:10.1109/peed69047.2026.00033
“HFTs are the core electromagnetic components in PETs responsible for voltage transformation and electrical isolation [3-5].”
Metadata
- Authors
- Li, Z., Hsieh, E., Li, Q., & Lee, F. C.
- Affiliations
- Virginia Tech (US)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2023-08
- Volume
- 38
- Issue
- 8
- Pages
- 9917-9932
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W4377224573
- Semantic Scholar
- 7b4f9ffb898071498fc91f0565aec5a09633e5ca
- Cited by
- 111
- References
- 46
- Citations by year
- 2026: 23 · 2025: 33 · 2024: 39 · 2023: 16
- FWCI
- 8.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Funders
- Office of Energy Efficiency and Renewable Energy
- U.S. Department of Energy (DE-EE0006521)
- North Carolina State University, Power America Institute
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Keywords
- solid-state transformer, high-frequency transformer design, resonant converter, CLLC converter, core loss, winding losses, power density, insulation coordination, epoxy insulation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).