CoChat

Investigation of Plasma Detachment From a Magnetic Nozzle in the Plume of the VX-200 Magnetoplasma Thruster

Olsen, Christopher S., Ballenger, Maxwell G., Carter, Mark D., Chang Diaz, Franklin R., Giambusso, Matthew, Glover, Timothy W., Ilin, Andrew V., Squire, Jared P., Longmier, Benjamin W., Bering, Edgar A., Cloutier, Paul A. · 2015 · IEEE Transactions on Plasma Science
Cited by 66

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Understanding the physics involved in plasma detachment from magnetic nozzles is well theorized, but lacking in large scale experimental support. We have undertaken an experiment using the 150-m3variable specific impulse magnetoplasma rocket test facility and VX-200 thruster seeking evidence that detachment occurs and an understanding of the physical processes involved. It was found that the plasma jet in this experiment does indeed detach from the applied magnetic nozzle (peak field sim~2 T) in a two part process. The first part involves the ions beginning to deviate from the nozzle field 0.8-m downstream of the nozzle throat. This separation location is consistent with a loss of adiabaticity where the ratio of the ion Larmor radius to the magnetic field scale length (r_Li|∇ B|B ) becomes of order unity and conservation of the magnetic moment breaks down. Downstream of this separation region, the dynamics of the unmagnetized ions and magnetized electrons, along with the ion momentum, affect the plume trajectory. The second part of the process involves the formation of plasma turbulence in the form of high-frequency electric fields. The ion and electron responses to these electric fields depend upon ion momentum, magnetic field line curvature, magnetic field strength, angle between the particle trajectories, and the effective momentum transfer time. In stronger magnetic field regions of the nozzle, the detached ion trajectories are affected such that the unmagnetized ions begin to flare radially outward. Further downstream as the magnetic field weakens, for higher ion momentum and along the edge of the plume, the fluctuating electric field enables anomalous cross-field electron transport to become more dominant. This cross-field transport occurs until the electric fields dissipate 2-m downstream of the nozzle throat and the ion trajectories become ballistic. This transition to ballistic flow correlates well with the sub-to-super Alfvénic flow transition (βk). There was no significant change observed to the applied magnetic field.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tps.2014.2321257

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 66

Metadata

Authors
Olsen, C. S., Ballenger, M. G., Carter, M. D., Chang Diaz, F. R., Giambusso, M., Glover, T. W., Ilin, A. V., Squire, J. P., Longmier, B. W., Bering, E. A., & Cloutier, P. A.
Venue
IEEE Transactions on Plasma Science
Published
2015-01
Volume
43
Issue
1
Pages
252-268
ISSN
  • 0093-3813 (ISSN-L)
  • 1939-9375
OpenAlex
W2087615406
Cited by
66
References
1
FWCI
2.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Investigation of Plasma Detachment From a Magnetic Nozzle in the Plume of the VX-200 Magnetoplasma Thruster. https://app.cochat.ai/papers/10.1109/tps.2014.2321257
The paper
Olsen, C. S., Ballenger, M. G., Carter, M. D., Chang Diaz, F. R., Giambusso, M., Glover, T. W., Ilin, A. V., Squire, J. P., Longmier, B. W., Bering, E. A., & Cloutier, P. A. (2015). Investigation of Plasma Detachment From a Magnetic Nozzle in the Plume of the VX-200 Magnetoplasma Thruster. IEEE Transactions on Plasma Science. https://doi.org/10.1109/tps.2014.2321257

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.