The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
A Supercapacitor-Based Energy Storage Substation for Voltage Compensation in Weak Transportation Networks
Open accessAbstract
A supercapacitive-storage-based substation for the compensation of resistive voltage drops in transportation networks is proposed. It allows to feed as a current source in any voltage conditions of the line. The system has been designed as a compensation substation to be placed at weak points like end-of-line stations, instead of additional feeding substations. A dedicated power-electronic converter with an associated control system for the stabilization of the voltage level at the point of coupling in case of strong perturbations is proposed. Practical results are also presented, which have been recorded from a reduced size prototype.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A supercapacitor-based energy-storage system for elevators with soft commutated interface
Rufer, A., & Barrade, P. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2002.803021 · Cited by 275
Self-citationA supercapacitor-based energy storage system for elevators with soft commutated interface
Rufer, A., & Barrade, P. (2002) · Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248) · doi:10.1109/ias.2001.955719 · Cited by 240
Self-citationFlywheel energy storage system for traction applications
Richardson, M. B. (2002) · International Conference on Power Electronics, Machines and Drives (PEMD) · doi:10.1049/cp:20020128 · Cited by 71
Barrade, P., Pittet, S., & Rufer, A. C. (2000) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · Cited by 65
Self-citation
Cited by
Energy Storage Systems for Transport and Grid Applications
Vazquez, S., Lukic, S. M., Galvan, E., Franquelo, L. G., & Carrasco, J. M. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2076414 · Cited by 1,347
González-Gil, A., Palacin, R., & Batty, P. (2013) · Energy Conversion and Management · doi:10.1016/j.enconman.2013.06.039 · Cited by 442
Control Strategy of Fuel Cell and Supercapacitors Association for a Distributed Generation System
Thounthong, P., Rael, S., & Davat, B. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.896477 · Cited by 355
Trovão, J. P., Pereirinha, P. G., Jorge, H. M., & Antunes, C. H. (2013) · Applied Energy · doi:10.1016/j.apenergy.2012.12.081 · Cited by 298
Metadata
- Authors
- Rufer, A., Hotellier, D., & Barrade, P.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2004-04
- Volume
- 19
- Issue
- 2
- Pages
- 629-636
- ISSN
- 0885-8977 (ISSN-L)
- OpenAlex
- W2117191244
- Cited by
- 254
- References
- 4
- FWCI
- 8.83
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.