VSC Transmission System Using Flying Capacitor Multilevel Converters and Hybrid PWM Control
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A high-voltage direct current (HVDC) transmission system based on three-level flying capacitor (FC) multilevel converters with hybrid pulse-width modulation (PWM) is presented in this paper. Selective harmonic elimination PWM (SHE-PWM) is used during normal operating conditions and is switched to phase-shifted sinusoidal PWM (PS-SPWM) during an asymmetric network fault. The generation of the switching patterns under SHE-PWM control for each power device is described taking into account the natural balancing of the FC voltages. A new and simple control method for balancing the FC voltages when using SHE-PWM is proposed which is based on the small change of the firing angle according to the polarity of the load current. The FC voltage ripple under SHE-PWM control is estimated and compared to that under PS-SPWM. A method to implement the proposed hybrid PWM with capacitor voltage balancing is also provided. Simulation studies on a 300-MW/plusmn150 kV voltage-source converter transmission system are presented to confirm the satisfactory performance of the proposed system under active and reactive power variations and single-phase fault conditions
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Teichmann, R., & Bernet, S. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.847285 · Cited by 578 · cited 1×
“While these multilevel converters have their respective merits and shortcomings, the selection of the converter topology is a detailed engineering design exercise [12].”
Background
Cited by
VSC-Based HVDC Power Transmission Systems: An Overview
Flourentzou, N., Agelidis, V. G., & Demetriades, G. D. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2008441 · Cited by 2,216
Self-citationTu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387
“The phase-shifted carrier-based PWM (PSC-PWM) method can automatically suppress all low-order harmonics for multilevel converters [25].”
MethodSelf-citationDynamic Performance of a Modular Multilevel Back-to-Back HVDC System
Saeedifard, M., & Iravani, R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050787 · Cited by 1,188
Modular Multilevel Converters for HVDC Applications: Review on Converter Cells and Functionalities
Nami, A., Liang, J., Dijkhuizen, F., & Demetriades, G. D. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2327641 · Cited by 1,042
Dahidah, M. S. A., Konstantinou, G., & Agelidis, V. G. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2355226 · Cited by 599
Self-citationDekka, A., Wu, B., Fuentes, R. L., Perez, M., & Zargari, N. R. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2742938 · Cited by 576
“them, the PWM-based three-level NPC is utilized in the second generation HVdc systems [207].”
Guan, M., & Xu, Z. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2192752 · Cited by 549
Predictive Control of a Modular Multilevel Converter for a Back-to-Back HVDC System
Qin, J., & Saeedifard, M. (2012) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2191577 · Cited by 428
Reviews on multilevel converter and modulation techniques
Hasan, N. S., Rosmin, N., Osman, D. A. A., & Musta’amal@Jamal, A. H. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.05.163 · Cited by 178
Kim, S.-M., Jeong, M.-G., Kim, J., & Lee, K.-B. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2848620 · Cited by 44
Metadata
- Authors
- Xu, L., & Agelidis, V. G.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2007-01
- Volume
- 22
- Issue
- 1
- Pages
- 693-702
- ISSN
- 0885-8977 (ISSN-L)
- OpenAlex
- W2123120490
- Cited by
- 89
- References
- 1
- FWCI
- 6.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.