Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 561

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Low-Voltage DC Distribution System for Commercial Power Systems With Sensitive Electronic Loads

Salomonsson, Daniel, Sannino, Ambra·2007·IEEE Transactions on Power Delivery

Abstract

In this paper, the use of DC power system to supply sensitive electronic loads is treated. First, general design issues regarding DC power systems are discussed, and then the measurement results from a scaled laboratory setup are presented. The results show that it is possible to supply sensitive electronic loads through an AC/DC interface, and to keep them online during grid transients. The use of a DC power system to supply sensitive electronic loads will have lower losses compared with a conventional AC uninterruptible power-supply solution due to fewer power conversion steps.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tpwrd.2006.883024

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 561

Metadata

Authors
Salomonsson, D., & Sannino, A.
Venue
IEEE Transactions on Power Delivery
Published
2007-07
Volume
22
Issue
3
Pages
1620-1627
ISSN
0885-8977 (ISSN-L)
OpenAlex
W2113229722
Cited by
561
References
7
FWCI
8.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Low-Voltage DC Distribution System for Commercial Power Systems With Sensitive Electronic Loads. https://app.cochat.ai/papers/10.1109/tpwrd.2006.883024
The paper
Salomonsson, D., & Sannino, A. (2007). Low-Voltage DC Distribution System for Commercial Power Systems With Sensitive Electronic Loads. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2006.883024

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.