The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Locating and Isolating DC Faults in Multi-Terminal DC Systems
Abstract
A VSC-MTDC (multi-terminal dc) system consists of voltage-source converters (VSCs) connected to a dc network at their dc terminals. The MTDC is most vulnerable to a dc fault which paralyses all the VSCs until the dc fault is cleared. As dc circuit breakers are expensive, this paper proposes a solution based on extinguishing the dc fault current by opening all the ac-circuit breakers (ac-CBs) which the VSCs are already equipped with on the ac-sides. However, it is necessary to identify which dc line is the faulted line (in case it is a permanent fault) so that it can be isolated by fast dc switches (which are much more economical than the dc circuit breakers), prior to restoring the MTDC system by re-closing all the ac-CBs. This paper presents the handshaking method, which locates and isolates the faulted dc line and restores the MTDC without telecommunication.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optimal acquisition and aggregation of offshore wind power by multiterminal voltage-source HVDC
Lu, W., & Ooi, B.-T. (2003) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2002.803826 · Cited by 333
Self-citationProtection of VSC-multi-terminal HVDC against DC faults
Tang, L., & Ooi, B.-T. (2003) · 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289) · doi:10.1109/psec.2002.1022539 · Cited by 161
Self-citation
Cited by
Operation, Control, and Applications of the Modular Multilevel Converter: A Review
Debnath, S., Qin, J., Bahrani, B., Saeedifard, M., & Barbosa, P. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2309937 · Cited by 2,210
DC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
HVDC Circuit Breakers: A Review Identifying Future Research Needs
Franck, C. M. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2095889 · Cited by 909
Short-Circuit and Ground Fault Analyses and Location in VSC-Based DC Network Cables
Yang, J., Fletcher, J. E., & O'Reilly, J. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2162712 · Cited by 790
Kumar, D., Zare, F., & Ghosh, A. (2017) · IEEE Access · doi:10.1109/access.2017.2705914 · Cited by 751
Metadata
- Authors
- Tang, L., & Ooi, B.-T.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2007-07
- Volume
- 22
- Issue
- 3
- Pages
- 1877-1884
- ISSN
- 0885-8977 (ISSN-L)
- OpenAlex
- W2148895869
- Cited by
- 640
- References
- 2
- FWCI
- 6.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.