The DOI matches its Crossref record.
Short-Circuit and Ground Fault Analyses and Location in VSC-Based DC Network Cables
Open accessAbstract
The application of high-power voltage-source converters (VSCs) to multiterminal dc networks is attracting research interest. The development of VSC-based dc networks is constrained by the lack of operational experience, the immaturity of appropriate protective devices, and the lack of appropriate fault analysis techniques. VSCs are vulnerable to dc-cable short-circuit and ground faults due to the high discharge current from the dc-link capacitance. However, faults occurring along the interconnecting dc cables are most likely to threaten system operation. In this paper, cable faults in VSC-based dc networks are analyzed in detail with the identification and definition of the most serious stages of the fault that need to be avoided. A fault location method is proposed because this is a prerequisite for an effective design of a fault protection scheme. It is demonstrated that it is relatively easy to evaluate the distance to a short-circuit fault using voltage reference comparison. For the more difficult challenge of locating ground faults, a method of estimating both the ground resistance and the distance to the fault is proposed by analyzing the initial stage of the fault transient. Analysis of the proposed method is provided and is based on simulation results, with a range of fault resistances, distances, and operational conditions considered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Design and Operation of a Hybrid Modular Multilevel Converter
Zeng, R., Xu, L., Yao, L., & Williams, B. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2320822 · Cited by 455
DC Microgrid Protection: A Comprehensive Review
Beheshtaein, S., Cuzner, R. M., Forouzesh, M., Savaghebi, M., & Guerrero, J. M. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2904588 · Cited by 365
Ali, Z., Terriche, Y., Hoang, L. Q. N., Abbas, S. Z., Hassan, M. A., Sadiq, M., Su, C.-L., & Guerrero, J. M. (2021) · IEEE Access · doi:10.1109/access.2021.3112383 · Cited by 104
Protection Systems for DC Shipboard Microgrids
Bayati, N., & Savaghebi, M. (2021) · Energies · doi:10.3390/en14175319 · Cited by 21
Rajpoot, S. C., Pandey, C., Rajpoot, P. S., Singhai, S. K., & Sethy, P. K. (2021) · Journal of Electrical Engineering & Technology · doi:10.1007/s42835-021-00715-7 · Cited by 17
Metadata
- Authors
- Yang, J., Fletcher, J. E., & O'Reilly, J.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2012-10
- Volume
- 59
- Issue
- 10
- Pages
- 3827-3837
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2073887634
- Cited by
- 790
- References
- 0
- FWCI
- 9.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Short-Circuit and Ground Fault Analyses and Location in VSC-Based DC Network Cables. https://app.cochat.ai/papers/10.1109/tie.2011.2162712
- The paper
- Yang, J., Fletcher, J. E., & O'Reilly, J. (2012). Short-Circuit and Ground Fault Analyses and Location in VSC-Based DC Network Cables. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2011.2162712
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.