The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Load Signature Study—Part I: Basic Concept, Structure, and Methodology
Abstract
Load signature is the unique consumption pattern intrinsic to each individual electrical appliance/piece of equipment. This paper focus on building a universal platform to better understand and explore the nature of electricity consumption patterns using load signatures and advanced technology, such as feature extraction and intelligent computing. Through this knowledge, we can explore and develop innovative applications to achieve better utilization of resources and develop more intelligent ways of operation. This paper depicts the basic concept, features of load signatures, structure and methodology of applying mathematical programming techniques, pattern recognition tools, and committee decision mechanism to perform load disaggregation. New indices are also introduced to aid our understanding of the nature of load signatures and different disaggregation algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Networks: A Comprehensive Foundation
Haykin, S. (1998) · Cited by 30,070
Nonintrusive appliance load monitoring
Hart, G. W. (1992) · Proceedings of the IEEE · doi:10.1109/5.192069 · Cited by 3,165
Laughman, C., Lee, K., Cox, R., Shaw, S., Leeb, S., Norford, L., & Armstrong, P. (2003) · IEEE Power and Energy Magazine · doi:10.1109/mpae.2003.1192027 · Cited by 572
Neural-Network-Based Signature Recognition for Harmonic Source Identification
Srinivasan, D., Ng, W. S., & Liew, A. C. (2006) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2005.852370 · Cited by 453
A Novel Method to Construct Taxonomy Electrical Appliances Based on Load Signaturesof
Lam, H., Fung, G., & Lee, W. (2007) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2007.381742 · Cited by 324
Farinaccio, L., & Zmeureanu, R. (1999) · Energy and Buildings · doi:10.1016/s0378-7788(99)00007-9 · Cited by 240
Using appliance signatures for monitoring residential loads at meter panel level
Sultanem, F. (1991) · IEEE Transactions on Power Delivery · doi:10.1109/61.97667 · Cited by 209
Nonintrusive monitoring of electric loads
Drenker, S., & Kader, A. (1999) · IEEE Computer Applications in Power · doi:10.1109/67.795138 · Cited by 187
Exploration on Load Signatures
Lee, W. K., Fung, G. S. K., Lam, H.-Y., Chan, F. H. Y., & Lucente, M. E. (2004) · Cited by 86
Modified Nonintrusive Appliance Load Monitoring For Nonlinear Devices
Akbar, M., & Khan, Z. A. (2007) · IEEE International Multitopic Conference (INMIC) · doi:10.1109/inmic.2007.4557691 · Cited by 57
Cited by
Non-Intrusive Load Monitoring Approaches for Disaggregated Energy Sensing: A Survey
Zoha, A., Gluhak, A., Imran, M., & Rajasegarar, S. (2012) · Sensors · doi:10.3390/s121216838 · Cited by 954
Nonintrusive appliance load monitoring: Review and outlook
Zeifman, M., & Roth, K. (2011) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2011.5735484 · Cited by 811
Is disaggregation the holy grail of energy efficiency? The case of electricity
Carrie Armel, K., Gupta, A., Shrimali, G., & Albert, A. (2013) · Energy Policy · doi:10.1016/j.enpol.2012.08.062 · Cited by 595
Big data analytics in smart grids: a review
Zhang, Y., Huang, T., & Bompard, E. F. (2018) · Energy Informatics · doi:10.1186/s42162-018-0007-5 · Cited by 382
An Empirical Investigation of V-I Trajectory Based Load Signatures for Non-Intrusive Load Monitoring
Hassan, T., Javed, F., & Arshad, N. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2271282 · Cited by 322
Metadata
- Authors
- Liang, J., Ng, S. K. K., Kendall, G., & Cheng, J. W. M.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2010-04
- Volume
- 25
- Issue
- 2
- Pages
- 551-560
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2025423356
- Cited by
- 453
- References
- 10
- FWCI
- 10.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.