A Hybrid Framework for Fault Detection, Classification, and Location—Part I: Concept, Structure, and Methodology
The DOI matches its Crossref record.
Abstract
Bridging the gap between the theoretical modeling and the practical implementation is always essential for fault detection, classification, and location methods in a power transmission-line network. In this paper, a novel hybrid framework that is able to rapidly detect and locate a fault on power transmission lines is presented. The proposed algorithm presents a fault discrimination method based on the three-phase current and voltage waveforms measured when fault events occur in the power transmission-line network. Negative-sequence components of the three-phase current and voltage quantities are applied to achieve fast online fault detection. Subsequently, the fault detection method triggers the fault classification and fault-location methods to become active. A variety of methods-including multilevel wavelet transform, principal component analysis, support vector machines, and adaptive structure neural networks-are incorporated into the framework to identify fault type and location at the same time. This paper lays out the fundamental concept of the proposed framework and introduces the methodology of the analytical techniques, a pattern-recognition approach via neural networks and a joint decision-making mechanism. Using a well-trained framework, the tasks of fault detection, classification, and location are accomplished in 1.28 cycles, significantly shorter than the critical fault clearing time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chen, K., Huang, C., & He, J. (2016) · High Voltage · doi:10.1049/hve.2016.0005 · Cited by 377
Guo, M.-F., Zeng, X.-D., Chen, D.-Y., & Yang, N.-C. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2776238 · Cited by 313
“It decreased fault capacitive current during a single-phase-to-ground fault which can make distribution systems stay in an operating state for 1 ∼ 2 h [1].”
BackgroundA Review on Fault Detection and Process Diagnostics in Industrial Processes
Park, Y.-J., Fan, S.-K. S., & Hsu, C.-Y. (2020) · Processes · doi:10.3390/pr8091123 · Cited by 277
A Machine Learning and Wavelet-Based Fault Location Method for Hybrid Transmission Lines
Livani, H., & Evrenosoglu, C. Y. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2260421 · Cited by 265
Chen, K., Hu, J., & He, J. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2598881 · Cited by 176
Lin, Z., Duan, D., Yang, Q., Hong, X., Cheng, X., Yang, L., & Cui, S. (2020) · IEEE Access · doi:10.1109/access.2020.3009385 · Cited by 21
Metadata
- Authors
- Jiang, J.-A., Chuang, C.-L., Wang, Y.-C., Hung, C.-H., Wang, J.-Y., Lee, C.-H., & Hsiao, Y.-T.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2011-07
- Volume
- 26
- Issue
- 3
- Pages
- 1988-1998
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2147401148
- Cited by
- 129
- References
- 0
- FWCI
- 14.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.