Operation and Control of Multiterminal HVDC Transmission for Offshore Wind Farms
Abstract
Three configurations of voltage source converter multi-terminal HVDC transmission for large offshore wind farms are studied. The voltage-current characteristics of the converters are shown and the operation of the converters with different power output from the wind farms is discussed. The control system is designed to achieve automatic coordination between the converters without the need of fast communication between them. The operation of the multi-terminal HVDC transmission with the control system is tested through simulations using PSCAD/EMTDC and through experiments on a three-terminal test rig. The simulation and experimental results show good agreement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Locating and Isolating DC Faults in Multi-Terminal DC Systems
Tang, L., & Ooi, B.-T. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2007.899276 · Cited by 640
Optimal acquisition and aggregation of offshore wind power by multiterminal voltage-source HVDC
Lu, W., & Ooi, B.-T. (2003) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2002.803826 · Cited by 333
(2004) · Power Electronics and Power Systems · doi:10.1007/b117759 · Cited by 292
Topologies of multiterminal HVDC-VSC transmission for large offshore wind farms
Gomis‐Bellmunt, O., Liang, J., Ekanayake, J. B., King, R. L., & Jenkins, N. (2010) · Electric Power Systems Research · doi:10.1016/j.epsr.2010.09.006 · Cited by 258
Self-citationHVDC transmission systems using voltage sourced converters design and applications
Schettler, F., Huang, H., & Christl, N. (2002) · 2000 Power Engineering Society Summer Meeting (Cat. No.00CH37134) · doi:10.1109/pess.2000.867439 · Cited by 213
A control system for HVDC transmission by voltage sourced converters
Nakajima, T., & Irokawa, S. (2003) · 199 IEEE Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.99CH36364) · doi:10.1109/pess.1999.787474 · Cited by 187
Voltage source converter transmission technologies: the right fit for the application
Bahrman, M., Johansson, J., & Nilsson, B. (2004) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2003.1267441 · Cited by 108
The Gotland HVDC Light project - experiences from trial and commercial operation
Axelsson, U. (2001) · International Conference and Exhibition on Electricity Distribution (CIRED) · doi:10.1049/cp:20010675 · Cited by 96
Gotland HVDC Light Transmission-World's First Commercial Small Scale DC Transmission
Axelsson, U. (1999) · Medical Entomology and Zoology · Cited by 45
Cited by
Dekka, A., Wu, B., Fuentes, R. L., Perez, M., & Zargari, N. R. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2742938 · Cited by 576
Metadata
- Authors
- Liang, J., Jing, T., Gomis-Bellmunt, O., Ekanayake, J., & Jenkins, N.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2011-10
- Volume
- 26
- Issue
- 4
- Pages
- 2596-2604
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2112368985
- Cited by
- 270
- References
- 9
- FWCI
- 14.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Operation and Control of Multiterminal HVDC Transmission for Offshore Wind Farms. https://app.cochat.ai/papers/10.1109/tpwrd.2011.2152864
- The paper
- Liang, J., Jing, T., Gomis-Bellmunt, O., Ekanayake, J., & Jenkins, N. (2011). Operation and Control of Multiterminal HVDC Transmission for Offshore Wind Farms. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2011.2152864
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.