CoChat

Impact of HVDC Transmission System Topology on Multiterminal DC Network Faults

Kontos, E., Pinto, R. Teixeira, Rodrigues, S., Bauer, P. · 2015 · IEEE Transactions on Power Delivery
Cited by 175

The DOI matches its Crossref record.

Abstract

This paper compares how a dc fault affects a multiterminal dc (MTdc) network depending on the HVDC transmission system topology. To this end, a six-step methodology is proposed for the selection of the necessary dc fault protection measures. The network consists of four voltage-source converters converters radially connected. The converters natural fault response to a dc fault for the different topologies is studied using dynamic simulation models. For clearing of the dc faults, four different dc breaker technologies are compared based on their fault interruption time, together with a current direction fault detection method. If necessary, the converters are reinforced with limiting reactors to decrease the peak value and rate of rise of the fault currents providing sufficient time for the breakers to isolate the fault without interrupting the MTdc network operation. The study shows that the symmetric monopolar topology is least affected by dc contingencies. Considering bipolar topologies, the bipolar with metallic return exhibits better fault response compared to the one with ground return. Topologies with ground or metallic return require full semiconductor or hybrid breakers with reactors to successfully isolate a dc fault.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tpwrd.2014.2357056

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Metadata

Authors
Kontos, E., Pinto, R. T., Rodrigues, S., & Bauer, P.
Venue
IEEE Transactions on Power Delivery
Published
2015-04
Volume
30
Issue
2
Pages
844-852
ISSN
  • 0885-8977 (ISSN-L)
  • 1937-4208
OpenAlex
W2013877857
Cited by
175
References
0
FWCI
9.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.