Analysis, Detection, and Location of Open-Switch Submodule Failures in a Modular Multilevel Converter
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The modular multilevel converter (MMC) has become one of the most promising converter topologies for medium/high-power applications. Since the MMC is structured based upon stacking up a number of series-connected identical submodules (SMs), to improve its fault tolerance and reliability, SM failure detection and location is of significant importance. In this paper, the impact of open-circuit switch failures of the SMs on the operation of the MMC is analyzed. Based on the analysis under SM failure conditions, two SM failure detection and location methods are proposed, that is, a clustering algorithm (CA)-based method and a calculated capacitance (CC)-based method. In the proposed CA-based method, a pattern-recognition-based fault diagnosis approach, which employs the clustering algorithm to detect and locate the faulty SMs with open-switch failures through identifying the pattern of 2-D trajectories of the SM characteristic variables, is developed. The proposed CC-based method is based on the calculation and comparison of a physical component parameter, that is, the nominal SM capacitance, and is capable of failure detection, location, and classification within one stage. The performance of the proposed failure detection methods for an MMC system is evaluated based on time-domain simulation studies in the PSCAD/EMTDC software environment. The reported study results demonstrate the capabilities of the two proposed methods in detecting and locating any SM failure under various conditions accurately and efficiently.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Survey of fault-tolerance techniques for three-phase voltage source inverters
Mirafzal, B. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2301712 · Cited by 440
Fault Diagnosis and Reconfiguration for Multilevel Inverter Drive Using AI-Based Techniques
Khomfoi, S., & Tolbert, L. M. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.906994 · Cited by 284
Cited by
Modular Multilevel Converters for Transportation Electrification: Challenges and Opportunities
Ronanki, D., & Williamson, S. S. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2792330 · Cited by 345
“detect and locate the faulty SM along with failed device [72].”
BackgroundOpen-Circuit IGBT Fault Detection and Location Isolation for Cascaded Multilevel Converters
Lamb, J., & Mirafzal, B. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2674629 · Cited by 170
“Thermomechanical fatigue is the main cause of IGBT failures [8], [19], [21], [24], and due to the inherent power and thermal cycling in some applications, e.”
BackgroundZhou, D., Yang, S., & Tang, Y. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2796584 · Cited by 143
Chen, Y., Li, Z., Zhao, S., Wei, X., & Kang, Y. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2632858 · Cited by 111
“In [18] and [19], SM fault is detected by sliding mode observer.”
BackgroundMethodLi, J., Konstantinou, G., Wickramasinghe, H. R., Pou, J., Wu, X., & Jin, X. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2747079 · Cited by 49
“Due to their wide application in power transmission systems and the requirements for high reliability and availability, MMCs need to handle a variety of fault conditions including i) sub-module (SM) failures [8]–[11], ii) dc-link short-circuit faults [12], [13], iii) asymmetric arm impedance conditions [14], iv) ac gr…”
Background
Metadata
- Authors
- Yang, Q., Qin, J., & Saeedifard, M.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2016-02
- Volume
- 31
- Issue
- 1
- Pages
- 155-164
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2284778013
- Cited by
- 140
- References
- 3
- FWCI
- 5.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.