Arm Current Control Strategy for MMC-HVDC Under Unbalanced Conditions
The DOI matches its Crossref record; 24 of the 26 references it cites were found in a registry or an index.
Abstract
Circulating current can be decomposed into double line-frequency positive-, negative- and zero-sequence components under unbalanced voltage conditions. First, in order to decrease peak/rms value of arm current, double line-frequency circulating current should be eliminated. Second, ac-side current that consists of positive- and negative-sequence components under unbalanced voltage conditions should be regulated to track the reference signal. Furthermore, fundamental frequency circulating current caused by asymmetry of the upper and lower arm should be also removed. To effectively control ac-side current and eliminate all circulating currents, an arm current control strategy based on a decoupler and proportional-integral controller plus the vector proportional integral (VPI) controller is proposed in this paper. The proposed control strategy works well under balanced and unbalanced voltage conditions as well as asymmetry of the upper and lower arm. In addition, this paper proposes a design procedure for the VPI controller to reduce the uncertainty of this process. A three-phase modular multilevel converter simulation model is set up on PSCAD/EMTDC to verify the effectiveness of the proposed control strategy.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Multivariable Feedback Control: Analysis and Design
Skogestad, S., & Postlethwaite, I. (1996) · Cited by 6,312
Proportional-resonant controllers and filters for grid-connected voltage-source converters
Teodorescu, R., Blaabjerg, F., Liserre, M., & Loh, P. C. (2006) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20060008 · Cited by 1,646 · cited 1×
“The transfer functions of PI controller plus resonant controllers and PI controller plus VPI controllers are given as [18]–[21]”
MethodTu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387 · cited 1×
“Reference [9] proposes a circulating current suppressing method in double line-frequency negative sequence rotational frame to eliminate negative-sequence second harmonic circulating current under balanced voltage conditions.”
MethodDynamic Performance of a Modular Multilevel Back-to-Back HVDC System
Saeedifard, M., & Iravani, R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050787 · Cited by 1,188
High Performance Current Controller for Selective Harmonic Compensation in Active Power Filters
Lascu, C., Asiminoaei, L., Boldea, I., & Blaabjerg, F. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.904060 · Cited by 521
Li, S., Wang, X., Yao, Z., Li, T., & Peng, Z. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2329059 · Cited by 343 · cited 2×
“If negative-sequence current is eliminated during the fault period, there are double line-frequency negative- and zerosequence circulating currents [8] .”
BackgroundMethodLascu, C., Asiminoaei, L., Boldea, I., & Blaabjerg, F. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2006953 · Cited by 337 · cited 1×
“According to the rule of pole-zero cancellation, the following relation must be satisfied [22]”
BackgroundWang, F., Duarte, J. L., & Hendrix, M. A. M. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2052289 · Cited by 327 · cited 1×
“To achieve three selective control targets, that is, obtaining symmetrical three-phase current, eliminating active power ripples and removing reactive power ripples, the following ac-side current reference is given [14]”
BackgroundAn Inner Current Suppressing Method for Modular Multilevel Converters
Li, Z., Wang, P., Chu, Z., Zhu, H., Luo, Y., & Li, Y. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2242204 · Cited by 271 · cited 1×
“Circulating current should be eliminated/minimized because it distorts arm current, increases peak/RMS value of arm current and may threaten the safe operation of the power devices [10].”
BackgroundAn Advanced Current Control Strategy for Three-Phase Shunt Active Power Filters
Trinh, Q.-N., & Lee, H.-H. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2229677 · Cited by 258
Cited by
Dekka, A., Wu, B., Fuentes, R. L., Perez, M., & Zargari, N. R. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2742938 · Cited by 576
“is presented in [159], where the combination of the PI regulator and vector PI regulator is used in the current”
Modular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“positive and negative sequences in the model to work with unbalanced voltages [61].”
BackgroundModel Predictive Control of High-Power Modular Multilevel Converters—An Overview
Dekka, A., Wu, B., Yaramasu, V., Fuentes, R. L., & Zargari, N. R. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2880137 · Cited by 231
“The dc-link current ripples increase the SM capacitor voltage ripple and the magnitude of circulating current, which has a cascading effect on the device conduction losses and voltage stress [64].”
BackgroundGuo, K., Cui, L., Mao, M., Zhou, L., & Zhang, Q. (2020) · IEEE Access · doi:10.1109/access.2020.2999311 · Cited by 206
“Currently, the topologies are widely applicable to high-power and high-voltage applications mainly including resonant circuits [7], [8] and modular multilevel [9], [10].”
BackgroundOperation and Control Methods of Modular Multilevel Converters in Unbalanced AC Grids: A Review
Li, J., Konstantinou, G. S., Wickramasinghe, H. R., & Pou, J. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2856505 · Cited by 115
“(b) Arm current control method by using PI + VPI [63].”
BackgroundMethodInfluential
Metadata
- Authors
- Liang, Y., Liu, J., Zhang, T., & Yang, Q.
- Affiliations
- North China Electric Power University (CN)
- Tsinghua University (CN)
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2017-02
- Volume
- 32
- Issue
- 1
- Pages
- 125-134
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2340609376
- Cited by
- 81
- References
- 26
- Citations by year
- 2025: 3 · 2024: 7 · 2023: 7 · 2022: 7 · 2021: 15 · 2020: 8 · 2019: 8 · 2018: 14 · 2017: 11
- FWCI
- 5.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Delivery (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Keywords
- modular multilevel converter, HVDC, circulating current elimination, voltage unbalance, decoupler, positive and negative sequence components, current tracking
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.