Arm Current Control Strategy for MMC-HVDC Under Unbalanced Conditions
The DOI matches its Crossref record; 24 of the 26 references it cites were found in a registry or an index.
Abstract
Circulating current can be decomposed into double line-frequency positive-, negative- and zero-sequence components under unbalanced voltage conditions. First, in order to decrease peak/rms value of arm current, double line-frequency circulating current should be eliminated. Second, ac-side current that consists of positive- and negative-sequence components under unbalanced voltage conditions should be regulated to track the reference signal. Furthermore, fundamental frequency circulating current caused by asymmetry of the upper and lower arm should be also removed. To effectively control ac-side current and eliminate all circulating currents, an arm current control strategy based on a decoupler and proportional-integral controller plus the vector proportional integral (VPI) controller is proposed in this paper. The proposed control strategy works well under balanced and unbalanced voltage conditions as well as asymmetry of the upper and lower arm. In addition, this paper proposes a design procedure for the VPI controller to reduce the uncertainty of this process. A three-phase modular multilevel converter simulation model is set up on PSCAD/EMTDC to verify the effectiveness of the proposed control strategy.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Multivariable Feedback Control: Analysis and Design
Skogestad, S., & Postlethwaite, I. (1996) · Cited by 6,312
Proportional-resonant controllers and filters for grid-connected voltage-source converters
Teodorescu, R., Blaabjerg, F., Liserre, M., & Loh, P. C. (2006) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20060008 · Cited by 1,646 · cited 1×
“The transfer functions of PI controller plus resonant controllers and PI controller plus VPI controllers are given as [18]–[21]”
MethodTu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387 · cited 1×
“Reference [9] proposes a circulating current suppressing method in double line-frequency negative sequence rotational frame to eliminate negative-sequence second harmonic circulating current under balanced voltage conditions.”
MethodDynamic Performance of a Modular Multilevel Back-to-Back HVDC System
Saeedifard, M., & Iravani, R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050787 · Cited by 1,188
High Performance Current Controller for Selective Harmonic Compensation in Active Power Filters
Lascu, C., Asiminoaei, L., Boldea, I., & Blaabjerg, F. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.904060 · Cited by 521
Li, S., Wang, X., Yao, Z., Li, T., & Peng, Z. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2329059 · Cited by 343 · cited 2×
“If negative-sequence current is eliminated during the fault period, there are double line-frequency negative- and zerosequence circulating currents [8] .”
BackgroundMethodLascu, C., Asiminoaei, L., Boldea, I., & Blaabjerg, F. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2006953 · Cited by 337 · cited 1×
“According to the rule of pole-zero cancellation, the following relation must be satisfied [22]”
BackgroundWang, F., Duarte, J. L., & Hendrix, M. A. M. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2052289 · Cited by 327 · cited 1×
“To achieve three selective control targets, that is, obtaining symmetrical three-phase current, eliminating active power ripples and removing reactive power ripples, the following ac-side current reference is given [14]”
BackgroundAn Inner Current Suppressing Method for Modular Multilevel Converters
Li, Z., Wang, P., Chu, Z., Zhu, H., Luo, Y., & Li, Y. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2242204 · Cited by 271 · cited 1×
“Circulating current should be eliminated/minimized because it distorts arm current, increases peak/RMS value of arm current and may threaten the safe operation of the power devices [10].”
BackgroundAn Advanced Current Control Strategy for Three-Phase Shunt Active Power Filters
Trinh, Q.-N., & Lee, H.-H. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2229677 · Cited by 258
Cited by
Dekka, A., Wu, B., Fuentes, R. L., Perez, M., & Zargari, N. R. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2742938 · Cited by 576
“is presented in [159], where the combination of the PI regulator and vector PI regulator is used in the current”
Modular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“positive and negative sequences in the model to work with unbalanced voltages [61].”
BackgroundModel Predictive Control of High-Power Modular Multilevel Converters—An Overview
Dekka, A., Wu, B., Yaramasu, V., Fuentes, R. L., & Zargari, N. R. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2880137 · Cited by 231
“The dc-link current ripples increase the SM capacitor voltage ripple and the magnitude of circulating current, which has a cascading effect on the device conduction losses and voltage stress [64].”
BackgroundGuo, K., Cui, L., Mao, M., Zhou, L., & Zhang, Q. (2020) · IEEE Access · doi:10.1109/access.2020.2999311 · Cited by 206
“Currently, the topologies are widely applicable to high-power and high-voltage applications mainly including resonant circuits [7], [8] and modular multilevel [9], [10].”
BackgroundOperation and Control Methods of Modular Multilevel Converters in Unbalanced AC Grids: A Review
Li, J., Konstantinou, G. S., Wickramasinghe, H. R., & Pou, J. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2856505 · Cited by 115
“(b) Arm current control method by using PI + VPI [63].”
BackgroundMethodInfluentialRaju, M. N., Sreedevi, J., Mandi, R. P., & Meera, K. S. (2019) · IET Power Electronics · doi:10.1049/iet-pel.2018.5734 · Cited by 115
Marzo, I., Sanchez-Ruiz, A., Barrena, J. A., Abad, G., & Muguruza, I. (2021) · IEEE Access · doi:10.1109/access.2021.3103337 · Cited by 93
Energy Balancing Improvement of Modular Multilevel Converters Under Unbalanced Grid Conditions
León, A. E., & Amodeo, S. J. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2621000 · Cited by 90
“The MMC was analyzed under unbalanced ac grid conditions in [24]–[33], but these studies are only focused on the output and circulating current controls, and they do not discuss the inter-arm energy balancing issue.”
Ou, Z., Wang, G., & Zhang, L. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2717541 · Cited by 58
“[22] proposed a PI plus vector proportional integral (VPI) controller, which has a better performance and stability margin than the PR controller.”
BackgroundMethodKurtoğlu, M., Eroğlu, F., Arslan, A. O., & Vural, A. M. (2018) · International Transactions on Electrical Energy Systems · doi:10.1002/etep.2763 · Cited by 57
Extended Current Limitation for Unbalanced Faults in MMC-HVDC-Connected Wind Power Plants
Schönleber, K., Prieto‐Araujo, E., Ratés‐Palau, S., & Gomis‐Bellmunt, O. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2786087 · Cited by 51
Li, J., Konstantinou, G., Wickramasinghe, H. R., Pou, J., Wu, X., & Jin, X. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2747079 · Cited by 49
“To avoid detrimental impact to the operation of the MMC from circulating currents under unbalanced ac grid conditions, previous work [17], [18], [21] considered additional controllers to suppress the even-order harmonic components in arm currents, including i) PI controllers in the positive and negative dq synchronous…”
BackgroundMethodInfluentialArm Current Balancing Control for Modular Multilevel Converters Under Unbalanced Grid Conditions
Wang, J., Tang, Y. K., & Liu, X. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2932003 · Cited by 45
“In [25], an arm current control strategy based on a PI controller plus a vector PI (VPI) controller is proposed, which is verified effective under balanced and unbalanced voltage conditions.”
MethodChen, X., Liu, J., Song, S., Ouyang, S., Wu, H., & Yang, Y. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2882690 · Cited by 43
“The first two objective controls can be realized by a proportional integral (PI) control strategy based on independent dq synchronous rotating frame [10] or a nonideal proportional resonant control strategy based on the abc or αβ frame [11], [12].”
BackgroundSelf-citationLiang, Y., Li, W., & Huo, Y. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2020.3030332 · Cited by 40
Self-citationAnalysis and Assessment of Modular Multilevel Converter Internal Control Schemes
Wang, S., Adam, G. P., Massoud, A. M., Holliday, D., & Williams, B. W. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2899794 · Cited by 39
“Once the MMC internal dynamics are controlled, its overall performance under normal and abnormal ac grid conditions, particularly its dynamic response due to the decoupling of SM capacitor voltage from the dc-link voltage, are improved [13]–[19].”
BackgroundAn Accelerated Distance Protection of Transmission Lines Emanating From MMC-HVdc Stations
Liang, Y., Huo, Y., & Zhao, F. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3058154 · Cited by 36
Self-citationLi, M., Chang, X., Dong, N., Liu, S., Yang, H., & Zhao, R. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3124315 · Cited by 34
Freytes, J. (2017) · theses.fr (ABES) · doi:10.70675/832379c5z047bz446fzbc43z7afc6f5d7baa · Cited by 51
Bergna‐Diaz, G., Suul, J. A., Berne, E., Vannier, J., & Molinas, M. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2894677 · Cited by 29
“Since the analysis and control of MMCs are currently being widely studied in the scientific community, several different methods have been proposed for controlling the circulating currents when operating under unbalanced grid voltage conditions [14]–[16], [18]–[20], [22]–[25].”
MethodInvestigation of MMC-HVDC operating region by circulating current control under grid imbalances
Li, J., Konstantinou, G. S., Wickramasinghe, H. R., Pou, J., Wu, X., & Jin, X. (2017) · Electric Power Systems Research · doi:10.1016/j.epsr.2017.07.003 · Cited by 27
An MMC Circulating Current Suppressing Controller Based on Bridge Arm Common-Mode Voltage
Yang, Z., Song, P., Song, J. C., Wang, X., & Li, X. S. (2020) · IEEE Access · doi:10.1109/access.2020.3031307 · Cited by 27
Liang, Y., Ren, Y., & Zhang, Z. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3187572 · Cited by 26
“gional power grids, the integration of offshore wind farms into power grid, and power supply to islands and remote areas [1]– [4].”
BackgroundSelf-citationCapacitor Voltage Reduction in Modular Multilevel Converters Under Grid Voltages Unbalances
Li, J., Konstantinou, G., Wickramasinghe, H. R., Townsend, C. D., & Pou, J. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2019.2919788 · Cited by 24
“MMC operation is shown in [32], and a comprehensive study, including tests with single, two and three phase to ground faults, have been carried out in [33].”
BackgroundModel Predictive Arm Current Control for Modular Multilevel Converter
Wang, Z., Yin, X., & Chen, Y. (2021) · IEEE Access · doi:10.1109/access.2021.3069079 · Cited by 24
“In view of that the PI plus PR controller cannot achieve ideal 0 dB amplitude response and 0 phase response at the resonant frequency for closed-loop transfer function, an arm current control strategy based on PI controller plus vector proportional integral (VPI) controller is presented in [2].”
BackgroundChalla, R. V. K., Mikkili, S., & Bonthagorla, P. K. (2022) · Journal of Control Automation and Electrical Systems · doi:10.1007/s40313-022-00953-8 · Cited by 24
Lai, J., Yin, X., Yin, X., Ullah, Z., Jiang, L., & Wang, Z. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3040297 · Cited by 20
Analysis and Protection Scheme of Station Internal AC Grounding Faults in a Bipolar MMC-HVDC System
Xue, S., Gu, C. Z., Liu, B., & Fan, B. (2020) · IEEE Access · doi:10.1109/access.2020.2971516 · Cited by 19
“INTRODUCTION Modular multilevel converter (MMC) based high-voltage dccurrent (HVDC) transmission has a good application prospect in fields of renewable energy integration, asynchronous interconnection of grids, and isolated power supply due to its advantages such as modularity, scalability, and high-quality output wav…”
BackgroundGharaghani, F., & Asadi, M. (2023) · Electrical Engineering · doi:10.1007/s00202-023-01908-1 · Cited by 19
“Additionally, an arm current control strategy based on decoupled parts and PI-based plus VPI-based controllers has been developed by [42].”
MethodLiu, Z., Miao, S., Fan, Z., Chao, K., & Liu, Y. (2018) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2018.08.037 · Cited by 18
Circulating Current Reduction in MMC-HVDC System Using Average Model
Hafeez, K., Khan, S., den Bossche, A. V., & Hasan, Q. U. (2019) · Applied Sciences · doi:10.3390/app9071383 · Cited by 17
Optimal Current Reference Calculation for MMCs Considering Converter Limitations
Spier, D. W., Prieto‐Araujo, E., López‐Mestre, J., & Gomis‐Bellmunt, O. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2020.3020420 · Cited by 18
Lee, S. S., & Heng, Y. E. (2017) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2017.07.011 · Cited by 17
Kurtoğlu, M., & Vural, A. M. (2022) · International Transactions on Electrical Energy Systems · doi:10.1155/2022/2169357 · Cited by 19
The Predictive Closed-Loop Averaging Control of MMC Phase-Unit Losses Under Unbalanced Conditions
Xu, J., Yu, Y., & Zhao, C. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2018.2868772 · Cited by 14
“Note that some energy based controllers [21], [22] can eliminate the double frequency components of the MMC arm currents.”
BackgroundMulti‐object control of an isolated DC–DC modular multilevel converter
Chen, Y., Zhao, S., Li, Z., & Kang, Y. (2018) · IET Power Electronics · doi:10.1049/iet-pel.2017.0151 · Cited by 14
Liu, W., Zheng, T., Liu, Z., Fan, Z., Kanɡ, Y., Wang, D., Zhang, M., & Miao, S. (2018) · Energies · doi:10.3390/en11113140 · Cited by 13
A voltage level based predictive direct power control for modular multilevel converter
Lee, S. S., & Heng, Y. E. (2017) · Electric Power Systems Research · doi:10.1016/j.epsr.2017.03.023 · Cited by 12
Internal Power Balancing of an MMC-Based Large-Scale PV System Under Unbalanced Voltage Sags
Elsanabary, A., Mekhilef, S., & Aziz, N. F. A. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2024.3399395 · Cited by 11
“An arm current control strategy with vector proportional integral (PI) controllers for controlling the dc, ac, and double frequency CC components is proposed in [29].”
BackgroundWang, Z., Yin, X., & Chen, Y. (2022) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2022.108048 · Cited by 11
Liang, Y., Ren, Y., Fan, Z., & Yang, X. (2023) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2023.109116 · Cited by 10
Self-citationUddin, W., Busarello, T. D. C., Zeb, K., Khan, M. A., Kumar, Y. A., & Kim, H. (2021) · Energies · doi:10.3390/en14144160 · Cited by 8
“In [26,27], the authors have proposed a control strategy based on arm current control.”
BackgroundPower Ripple Control Method for Modular Multilevel Converter under Grid Imbalances
Alharbi, M., Isik, S., Alkuhayli, A. A., & Bhattacharya, S. (2022) · Energies · doi:10.3390/en15103535 · Cited by 8
“The authors in [20] proposed to control the arm currents with PI and a vector PI.”
BackgroundImproved Current Reference Calculation for MMCs Internal Energy Balancing Control
Spier, D. W., Prieto‐Araujo, E., López‐Mestre, J., & Gomis‐Bellmunt, O. (2021) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2021.3091013 · Cited by 7
Montoya-Acevedo, D. A., Buitrago-Herrera, J. C., & Mejía, A. E. (2017) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2017.8096502 · Cited by 8
A Novel Control Strategy of MMC-HVDC System under SLG and PTG Fault Conditions
Shadlu, M. S. (2022) · Power Electronics, Drive Systems, and Technologies Conference (PEDSTC) · doi:10.1109/pedstc53976.2022.9767363 · Cited by 6
Tian, R., Wu, X., Jing, L., Xu, W., Sun, Z., & Cao, W. (2023) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2023.3323503 · Cited by 5
“In [26], [27], and [28], integrated control based on arm currents is proposed, ac and dc components can be controlled at the same time, facilitating the dynamical analysis of currents.”
BackgroundZhang, D., Sha, D., Zhao, Y., Gao, C., & Liu, X. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3552808 · Cited by 5
“Therefore,itisadoptedtosimplifythe overallstructureofthecurrentcontroller[37],[38],[39],[40].”
InfluentialMMC‐HVDC AC side line protection based on positive sequence fault component current ratio
Huang, H., & Wang, Z. (2023) · IET Generation Transmission & Distribution · doi:10.1049/gtd2.12979 · Cited by 5
HVDC grids with heterogeneous configuration stations under DC asymmetrical operation
Serrano-Sillero, J., Moreno, M. Á., & Morales, A. (2019) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.05.053 · Cited by 7
Challa, R. V. K., Mikkili, S., & Bonthagorla, P. K. (2022) · IETE Journal of Research · doi:10.1080/03772063.2022.2143438 · Cited by 5
“[152] 6 PIandVPI ω + 2 ω ( abc ) Pros-There was an increase in controller effectiveness.”
BackgroundZhao, C., Gao, F., Li, Z., Wang, P., & Li, Y. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2020.3014657 · Cited by 5
“In [17] and [18], the symmetrical ac currents can be obtained by controlling the arm currents appropriately, while the energy balance is improved in [19] through a feedback/feed-forward control strategy.”
BackgroundBalamurugan, S., & Nageswari, S. (2021) · Journal of Intelligent & Fuzzy Systems · doi:10.3233/jifs-210528 · Cited by 4
Small-signal stability analysis of the asymmetrical DC operation in HVDC networks
Serrano-Sillero, J., & Moreno, M. Á. (2022) · Electric Power Systems Research · doi:10.1016/j.epsr.2022.108942 · Cited by 4
Wang, X., Yang, W., Shi, Z., Fu, C., Lin, B., & Yang, L. (2021) · Asia Conference on Power and Electrical Engineering (ACPEE) · doi:10.1109/acpee51499.2021.9436867 · Cited by 4
“The arm currents are used as the control variables in [14] and [15], which can further simplify the calculation process of the current reference values.”
MethodCai, H., Zhang, J., Yu, J., & Zhang, Z. (2021) · Applied Sciences · doi:10.3390/app11062882 · Cited by 3
Sen, D., Mahapatra, R. K., Saha, T. K., & Dey, J. (2018) · International Conference on Power, Instrumentation, Control and Computing (PICC) · doi:10.1109/picc.2018.8384769 · Cited by 3
“Type 2 and type 3 controllers are used to control multi-input dc-dc converter neglecting the cross-coupling dynamics in [7] and decoupler is developed for multilevel inverter in [8].”
MethodWang, X., Cai, X., Chen, Q., Lin, B., & Xie, R. J. (2021) · IEEE Access · doi:10.1109/access.2021.3073950 · Cited by 3
“theY0/1 arrangement transformer under SLG fault [12]-[17].”
MethodPerformance of Modular Multilevel Converter in Electric Vehicles Charging Station
S.Jaanaa Rubavathy, P. V. S. A. (2024) · Journal of Electrical Systems · doi:10.52783/jes.1467 · Cited by 3
“The advantages on the specific applications are suppression of circulating current [14], energy storing in EV batteries [15], balancing the capacitor Voltage [16], and controlling the current in Upper arm and Lower arm [17], Hybrid Renewable Energy System [18], Motor Drives [19].”
BackgroundYang, W., Zhang, H., Li, J., Zhang, A., Zhou, Y., & Wang, J. (2018) · Energies · doi:10.3390/en11102599 · Cited by 3
A Control Method of DC Capacitor Voltage in MMC for HVDC System using Negative Sequence Current
Jaffar, H. A. B., Rahman, A. A. B. A., & Kakigano, H. (2018) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec.2018.8502769 · Cited by 3
Capacitor Ripple Reduction with Novel Modulation Scheme in Modular Multilevel Converters
Rahmati, S., Veysinejad, A., & Bina, M. T. (2020) · Power Electronics, Drive Systems, and Technologies Conference (PEDSTC) · doi:10.1109/pedstc49159.2020.9088441 · Cited by 3
Control Strategy for VSC-HVDC under Unbalanced Grid Voltages
Li, D., & Cai, T. (2017) · Applied Mechanics and Materials · doi:10.4028/www.scientific.net/amm.863.214 · Cited by 2
Offset PWM in modular multilevel converters for capacitor voltage reduction under grid imbalances
Li, J., Konstantinou, G. S., Wickramasinghe, H. R., Pou, J., & Jin, X. (2017) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2017.8216781 · Cited by 2
“Circulating Current Control Under imbalanced ac grid conditions, the most direct method to control the circulating current is to eliminate its double-line-frequency components [6], [16], [19], [20].”
MethodZhang, C., Hua, Y., Du, Y., & Liu, H. (2018) · IEEE Conference on Industrial Electronics and Applications (ICIEA) · doi:10.1109/iciea.2018.8398049 · Cited by 1
“Reference [6] proposed a novel arm current control strategy to suppress the fundamental-frequency components of the inner circulating current caused by asymmetry of the upper and lower arm.”
BackgroundArm Balance Control Scheme of Novel Isolated Modular Multilevel Converter (I-MMC)
Lin, L., Qi, C., Wu, X., Liu, C., Li, J., & Kong, D. (2019) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.23919/icpe2019-ecceasia42246.2019.8797028 · Cited by 1
“Reference [5] proposes a novel current control strategy for the arm, which suppresses the fundamental frequency circulating current component in the asymmetric operation of the upper and lower arm of the MMC.”
BackgroundStudy of Superconducting Fault Current Limiters for MMC-MTDC with HVDC CBs
Sun, J., Han, X. J., Li, Y., Zhang, Z., Xu, Z. G., & Xu, Y. (2019) · IEEE Innovative Smart Grid Technologies-Asia · doi:10.1109/isgt-asia.2019.8881817 · Cited by 1
“INTRODUCTION With the development of power electronics in recent years, the modular multilevel converter (MMC) becomes a preferred topology for high-voltage bulk power transmission, for its combination of low power losses with excellent output waveform [1], [2].”
BackgroundVozikis, D., Alsokhiry, F., & Adam, G. P. (2021) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2021.107266 · Cited by 1
Tian, R., Wu, X., Jing, L., Tang, F., & Sun, Z. (2024) · Asia Conference on Power and Electrical Engineering (ACPEE) · doi:10.1109/acpee60788.2024.10532614 · Cited by 1
“In [13] ,[14], [15], control schemes based on arm currents to achieve integrated method of AC and DC currents is suggested, but the hierarchical method is complex to achieve.”
MethodDual-Port Grid-Forming Control in MMC-Based ES-STATCOM for Enhanced Voltage Stability
Aladhyani, H., Alosaimi, H., Alshammari, S., & Bhattacharya, S. (2024) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce55643.2024.10861792 · Cited by 1
High-power modular multilevel converters: Modeling, modulation and control
Dekka, A. (2021) · doi:10.32920/ryerson.14645475.v1 · Cited by 1
Fawzi, M., Elsanabary, A., & Mekhilef, S. (2023) · Research Square · doi:10.21203/rs.3.rs-2526607/v1 · Cited by 1
Analysis of the inner unbalanced current for modular multilevel converter
Liu, J., Zhang, C., Ye, H., Wang, C., & Wu, G. (2018) · IEEE Conference on Industrial Electronics and Applications (ICIEA) · doi:10.1109/iciea.2018.8397996
“Reference [4] pointed that the foundational-frequency components will emerge when the upper and lower arms of MMC are asymmetrically operated.”
BackgroundSelf-citationControl of MMCs Under AC Grid Faults
Deng, F., Liu, C., & Chen, Z. (2023) · Wiley eBooks · doi:10.1002/9781119875635.ch6
An MMC control strategy without bridge arm current sensors
Chen, Y., Zhao, M., Zhang, Z., & Zeng, S. (2023) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2584/1/012064
“At present, the focus and difficulty of research on MMC are mostly focused on stability analysis [4], modulation strategies [5], and circulating current suppression [6][7].”
BackgroundElectromagnetic Transient Simulation of AC/DC Hybrid Power Grid with Hierarchical Access to UHVDC
Chen, D., Lin, J., Wang, F., Yang, Y., Fan, W., Lu, M., & He, Y. (2024) · International Conference on Energy and Electrical Power Systems (ICEEPS) · doi:10.1109/iceeps62542.2024.10693216
“…mechanism after DC access, and the interaction and influence mechanism between AC and DC systems in the power grid containing UHVDC have been discussed in reference [11-13] using PSS/E simulation software, revealing the possibility of instability of AC and DC parallel operation power grids.”
MethodYou, Y., Yu, M., Fan, X., Qi, L., & Teng, J. (2024) · Electronics · doi:10.3390/electronics13204043
Control Strategy Based on Second-Order Linear Active Disturbance Rejection for Flexible DC Grids
Zhao, J., Li, H., & Qi, K. (2024) · International Conference on Smart Grid and Smart Cities (ICSGSC) · doi:10.1109/icsgsc62639.2024.10813647
“Reference [5] presented a quasi-proportional resonant controller based on αβ coordinate system to suppress the negative sequence current under asymmetric AC conditions.”
A Multi-Objective Predictive Control Approach for PV-MMC under Unbalanced Grid Operations
Sharma, A., Chilipi, R., & Kumar, K. V. P. (2025) · IEEE International Conference on Sustainable Energy and Future Electric Transportation (SEFET) · doi:10.1109/sefet65155.2025.11255050
“Similarly, other control techniques such as PI plus vector PI (VPI) control method [10] and proportional controller with duty ratio feed-forward [11] scheme are developed to regulate arm currents of the MMC during an unbalanced grid.”
Research on bipolar short-circuit fault protection strategy based on CTB-MMC
Cui, G., Li, H., Chen, R., Yang, M. J., Deng, F., Lin, J., Wang, Z., & Tong, W. (2025) · International Conference on Power and Renewable Energy (ICPRE) · doi:10.1109/icpre67300.2025.11274156
“…MMC-HVDC has emerged as a pivotal technology for addressing the challenges associated with renewable energy grid integration and long-distance power transmission, by virtue of its exceptional power control capability, superior harmonic performance, and modular design advantages[1][2][3][4].”
Metadata
- Authors
- Liang, Y., Liu, J., Zhang, T., & Yang, Q.
- Affiliations
- North China Electric Power University (CN)
- Tsinghua University (CN)
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2017-02
- Volume
- 32
- Issue
- 1
- Pages
- 125-134
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2340609376
- Cited by
- 81
- References
- 26
- Citations by year
- 2025: 3 · 2024: 7 · 2023: 7 · 2022: 7 · 2021: 15 · 2020: 8 · 2019: 8 · 2018: 14 · 2017: 11
- FWCI
- 5.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Delivery (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Keywords
- modular multilevel converter, HVDC, circulating current elimination, voltage unbalance, decoupler, positive and negative sequence components, current tracking
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.