Impact of Circulating Current Control in Capacitor Voltage Ripples of Modular Multilevel Converters Under Grid Imbalances
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
The negative-sequence current of a modular multilevel converter (MMC) under unbalanced ac grid conditions increases the voltage ripples of the submodule capacitors. This paper investigates the impact of circulating current control in capacitor voltage ripples under different unbalanced ac grid conditions, while considering multiple control objectives and independent control of active and reactive power. It is demonstrated that higher order harmonic injection in the circulating current through a reference calculation based on instantaneous information improves operation of the MMC reducing capacitor voltage ripples at the cost of increased peak arm current and dc current oscillations. The efficacy of the circulating current control is validated through real-time digital simulations of an 800 MVA benchmark MMC high-voltage direct current transmission system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

















Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“When the MMC operates under unbalanced voltages, a fundamental frequency appears in the ac power and, due to the interaction of the arm currents, increases the amplitude of the capacitor voltage ripple [102].”
From Modular Multilevel Converters: Recent Achievements and Challenges (2021) · cites this paper as [102]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Understanding Power Quality Problems
Bollen, M. H. (1999) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470546840 · Cited by 1,386 · cited 1×
“Unbalanced voltage sags caused by single-phase or two-phase short circuits and are the most common types of sags [26].”
BackgroundDynamic Performance of a Modular Multilevel Back-to-Back HVDC System
Saeedifard, M., & Iravani, R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050787 · Cited by 1,188 · cited 1×
“THE modularity and scalability of modular multilevel converters (MMCs), among other advantages, have made the MMC a particularly attractive topology for high-voltage direct current (HVDC) transmission systems [1]–[3] and multiterminal networks [4].”
BackgroundGuan, M., & Xu, Z. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2192752 · Cited by 549 · cited 8×
“The most direct method to control the circulating current is to eliminate its ac component [17], [18], [21], [27].”
BackgroundMethodInfluentialModular Multilevel Converter topologies with DC-Short circuit current limitation
Marquardt, R. (2011) · 8th International Conference on Power Electronics - ECCE Asia · doi:10.1109/icpe.2011.5944451 · Cited by 413
Pou, J., Ceballos, S., Konstantinou, G., Agelidis, V. G., Picas, R., & Zaragoza, J. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2336608 · Cited by 406 · cited 5×
“Several methods [28]–[30] for reducing the capacitor ripples have been proposed in balanced operation.”
BackgroundMethodSelf-citationProtection of Nonpermanent Faults on DC Overhead Lines in MMC-Based HVDC Systems
Li, X., Song, Q., Liu, W., Rao, H., Xu, S., & Li, L. (2013) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2226249 · Cited by 402 · cited 1×
“Due to their wide application in power transmission systems and the requirements for high reliability and availability, MMCs need to handle a variety of fault conditions including i) sub-module (SM) failures [8]–[11], ii) dc-link short-circuit faults [12], [13], iii) asymmetric arm impedance conditions [14], iv) ac gr…”
BackgroundFault Detection for Modular Multilevel Converters Based on Sliding Mode Observer
Shao, S., Wheeler, P. W., Clare, J. C., & Watson, A. J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2242093 · Cited by 361 · cited 1×
“Due to their wide application in power transmission systems and the requirements for high reliability and availability, MMCs need to handle a variety of fault conditions including i) sub-module (SM) failures [8]–[11], ii) dc-link short-circuit faults [12], [13], iii) asymmetric arm impedance conditions [14], iv) ac gr…”
BackgroundLi, S., Wang, X., Yao, Z., Li, T., & Peng, Z. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2329059 · Cited by 343 · cited 6×
“The most direct method to control the circulating current is to eliminate its ac component [17], [18], [21], [27].”
BackgroundMethodInfluentialLi, B., Shi, S., Wang, B., Wang, G., Wang, W., & Xu, D. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2454534 · Cited by 329
Wang, F., Duarte, J. L., & Hendrix, M. A. M. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2052289 · Cited by 327 · cited 2×
“However, the approach of [32] develops independent control strategies for the ripple content of the active and reactive power based on two simple parameters, later combining them into a common controller.”
Background
Research works printed but not linked: 4
- Georgios Konstantinou (S'08-M'11) received the B.Eng. degree in electrical and computer engineer- ing from the Aristotle University of Thessaloniki, Thessaloniki, Greece, in 2007 and the Ph.D. degree in electrical engineering from UNSW Sydney (The University of New South Wales), Australia, in 2012. From 2012 to 2015 he was a Research Associate at UNSW . He is currently a Lecturer with the School of Electrical Engineering and Telecommunications at UNSW and an Australian Research Council (ARC) Early Career Research Fellow. His main research interests include hybrid and modular multilevel converters, power electronics for HVDC and energy storage applications, pulse width modulation and selective harmonic elimination techniques for power electronics. He is an Associate Editor for IEEE Transactions on Power Electronics and IET Power Electronics.
- R. Picas, J. Pou, S. Ceballos, V. G. Agelidis, and M. Saeedifard, "Minimization of the capacitor voltage fluctuations of an MMC by circulating current control," in Proc. IEEE-IECON Conf., Oct. 2012, pp. 4985-4991.
- L. Popova, J. Pyrhnen, K. Ma, and F. Blaabjerg, "Device loading of MMC in wind power application," in Proc. IEEE-IPEC Conf. (ECCE ASIA), May 2014, pp. 548-554.
- S. P. Engel and R. W. D. Doncker, "Control of the MMC for minimized cell capacitance," in Proc.EPE Conf., Aug. 2011, pp. 1-10.
Cited by
Modular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“amplitude of the capacitor voltage ripple [102].”
Self-citationNguyen, T. H., Hosani, K. A., Moursi, M. S. E., & Blaabjerg, F. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2862247 · Cited by 173
Operation and Control Methods of Modular Multilevel Converters in Unbalanced AC Grids: A Review
Li, J., Konstantinou, G. S., Wickramasinghe, H. R., & Pou, J. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2856505 · Cited by 115
“injection method-based instantaneous information was used in [92].”
MethodSelf-citationRecent Advancements in Submodule Topologies and Applications of MMC
Ali, S., Ling, Z., Tian, K., & Huang, Z. M. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2990689 · Cited by 119
Samajdar, D., Bhattacharya, T., & Dey, S. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2896932 · Cited by 59
An Improved Multiport DC Power Flow Controller for VSC-MTDC Grids
Wu, W., Wu, X., Zhao, Y., Wang, L., Zhao, T., & Jing, L. (2020) · IEEE Access · doi:10.1109/access.2020.2964309 · Cited by 28
“With the shortage of traditional energy and the deterioration of the ecological environment, the widely utilization of green and clean energy has become an inevitable trend [1].”
BackgroundSelf-citationCapacitor Voltage Reduction in Modular Multilevel Converters Under Grid Voltages Unbalances
Li, J., Konstantinou, G., Wickramasinghe, H. R., Townsend, C. D., & Pou, J. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2019.2919788 · Cited by 24
“An 800-MVA MMC-HVDC transmission system schematic [8], [18] was developed and simulated on a real-time digital”
MethodSelf-citationModel Predictive Arm Current Control for Modular Multilevel Converter
Wang, Z., Yin, X., & Chen, Y. (2021) · IEEE Access · doi:10.1109/access.2021.3069079 · Cited by 24
Challa, R. V. K., Mikkili, S., & Bonthagorla, P. K. (2022) · Journal of Control Automation and Electrical Systems · doi:10.1007/s40313-022-00953-8 · Cited by 24
“Energy sum is constant Cons—Implementation is difficult in practice Li et al. (2017) Instantaneous information (abc), 3PI(abc) and 3PR( abc) Pros—Calculation made simpler.”
BackgroundMethodMusarrat, M. N., Islam, M. R., Muttaqi, K. M., & Sutanto, D. (2021) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2021.3083636 · Cited by 22
“In [4], the impact of the circulating current control on the voltage ripple was analyzed under grid disturbances.”
BackgroundGharaghani, F., & Asadi, M. (2023) · Electrical Engineering · doi:10.1007/s00202-023-01908-1 · Cited by 19
Machine Current Sensor FDI Strategy in PMSMs
Li, H., Qian, Y., Asgarpoor, S., & Sharif, H. (2019) · IEEE Access · doi:10.1109/access.2019.2950429 · Cited by 21
“For case (a), there is a fault other than machine current sensor fault that causes an incorrect calculation of rib, such as circulating current inside the power inverter [25].”
BackgroundActive Damping Control of Multiport DC Power Flow Controller for MMC-MTDC With Unbalanced AC Grid
Wu, W., Wu, X., Wang, L., Zhao, T., Jing, L., & Li, J. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3007734 · Cited by 17
Self-citationRaza, A., Chen, Y., Li, M., Bhutto, Y. A., Ali, A., & Ali, A. (2024) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2024.115142 · Cited by 15
A New Phase Sequence Exchanging Control Method for Reducing Impulse Current and Voltage
Li, Y., Huang, S., Li, H., Zhang, J., Huang, G., & Luo, Y. (2019) · IEEE Access · doi:10.1109/access.2019.2951379 · Cited by 15
Tanta, M., Pinto, J. G. O., Monteiro, V., Martins, A., Carvalho, A., & Afonso, J. L. (2020) · Applied Sciences · doi:10.3390/app10051849 · Cited by 12
“In that case, improved control strategies were developed based on circulating current injection [19,20].”
BackgroundInternal Power Balancing of an MMC-Based Large-Scale PV System Under Unbalanced Voltage Sags
Elsanabary, A., Mekhilef, S., & Aziz, N. F. A. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2024.3399395 · Cited by 11
“…controls for the MMC-based high voltage direct current (HVDC) transmissions are proposed to mitigate the effect of voltage sags, define the boundaries of operation [22] and degrees of freedom [23], control the SM voltage ripples [24], and endure a balanced operation of the system [25], [26].”
BackgroundInvestigate on a Simplified Multi-Port Interline DC Power Flow Controller and Its Control Strategy
Wu, W., Wu, X., Jing, L., & Yin, J. (2019) · Energies · doi:10.3390/en12132480 · Cited by 11
“To ensure the consumption and efficient use of the large scale new energy, effective transmission technology is needed as a support [1].”
BackgroundSelf-citationPractical Submodule Capacitor Sizing for Modular Multilevel Converter Considering Grid Faults
Yin, Z., Qiu, H., Yang, Y., Tang, Y. K., & Wang, H. (2020) · Applied Sciences · doi:10.3390/app10103550 · Cited by 11
“For instance, the impact of the circulating current suppresion control (CCSC) on SM capacitor voltage ripples under different unbalanced AC grid conditions is discussed in [23].”
BackgroundYang, S., Shao, Z., Zheng, W., & Chen, F. (2019) · IEEE Access · doi:10.1109/access.2019.2953790 · Cited by 9
Zhang, H., Wickramasinghe, H. R., Jing, L., Li, J., Pou, J., & Konstantinou, G. S. (2019) · Electric Power Systems Research · doi:10.1016/j.epsr.2019.01.041 · Cited by 9
Self-citationA Submodule-Capacitor Voltage Balancing Strategy for Alternative-Arm Converters in HVDC Systems
Nguyen, T. H., Hosani, K. H. A., Moursi, M. S. E., & Sayari, N. A. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2019.2897250 · Cited by 9
“gle, the ripples of the voltages on the SM capacitors are reduced [25].”
BackgroundNiu, X., Qiu, R., Liu, S., & Chow, X. (2024) · Electronics · doi:10.3390/electronics13173379 · Cited by 6
Challa, R. V. K., Mikkili, S., & Bonthagorla, P. K. (2022) · IETE Journal of Research · doi:10.1080/03772063.2022.2143438 · Cited by 5
“[168] (abc), 3 PI ( abc ) and 3 PR ( abc ) Pros-Making calculations easier.”
Wang, T., Lin, H., Wang, Z., Ma, Y., & Wang, X. (2018) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2018.8557722 · Cited by 4
“However, the capacitor voltage balancing control and the circulating current control are needed additionally [12].”
BackgroundYin, Z., Yang, Y., & Wang, H. (2018) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec.2018.8507962 · Cited by 4
“The interaction between the circulating current control and the SM voltage stress in an imbalanced grid is proposed in [10], while the impact of the SM voltage balancing control is investigated in [11].”
BackgroundModification of SPWM Modulating Signals for Energy Balancing Purposes
Reyes-Severiano, Y., Aldaco, S. E. D. L., Aguayo, J., Carrillo-Santos, L. M., Lozoya-Ponce, R. E., & Medrano-Hermosillo, J. A. (2022) · Electronics · doi:10.3390/electronics11182871 · Cited by 3
Dash, J. R., Raj, R., & Agarwal, P. (2025) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2025.3634453 · Cited by 3
“These strategies include a range of control techniques such as proportional–resonant (PR) control [5], [6], [7], [8], [9], proportional–integral (PI) control [10], [11], [12], [13], [14], [15], [16], model predictive control (MPC) [17], [18], [19], [20], and H ∞ control [21].”
A new control strategy for MMC under grid voltage unbalance condition
Sun, W., Cheng, Q., Cheng, Y., Tan, F., Li, T., & Chen, L. (2019) · International Transactions on Electrical Energy Systems · doi:10.1002/2050-7038.2829 · Cited by 3
Alia, I., Merzouk, I., & Osama, A. M. (2023) · International Conference on Decision Aid Sciences and Applications (DASA) · doi:10.1109/dasa59624.2023.10286773 · Cited by 3
DC‐type grid‐connection system of PV generation and its control schemes
Dai, Z., Zhu, H., Lu, H., Liu, B., & Liu, Y. (2019) · International Transactions on Electrical Energy Systems · doi:10.1002/2050-7038.12059 · Cited by 2
Offset PWM in modular multilevel converters for capacitor voltage reduction under grid imbalances
Li, J., Konstantinou, G. S., Wickramasinghe, H. R., Pou, J., & Jin, X. (2017) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2017.8216781 · Cited by 2
“The aim of this paper is to investigate the impact of offset PWM (OPWM) in the operation of the MMC under imbalanced acgrid conditions [15] and quantify its impact with simulation results based on an 800-MVA HVDC transmission system.”
MethodSelf-citationYin, Z., Qiu, H., Yang, Y., Tang, Y. K., & Wang, H. (2019) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2019.8912833 · Cited by 2
“In [17], the impact of the CCSC on SM capacitor voltage ripples under different unbalanced ac grid conditions is discussed.”
BackgroundDesign and Selection of MMC Parameters for Improved Performance in Grid Forming Mode
Singh, P. K., Rao, N. P., & Shukla, A. (2023) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias54024.2023.10406712 · Cited by 1
Reyes-Severiano, Y., Ponce‐Silva, M., Carrillo-Santos, L. M., Aldaco, S. E. D. L., Aguayo, J., & Castillo-Pineda, B. (2026) · Eng—Advances in Engineering · doi:10.3390/eng7040185 · Cited by 1
Analysis and Control of Single Phase Grid Connected Modular Multilevel Converter in Per Unit
BEYHAN, E., & Akpınar, E. (2020) · European Mechanical Science · doi:10.26701/ems.622397 · Cited by 1
Control of Modular Multilevel Converter under Unequal Arm Capacitor Values
Kocamiş, A. E., & Akpınar, E. (2021) · International Conference on Electrical Energy Systems (ICEES) · doi:10.1109/icees51510.2021.9383715 · Cited by 1
“3 [5, 6], The feedforward controller is added in the reactive power control block to reduce the settling time during load transients.”
BackgroundFawzi, M., Elsanabary, A., & Mekhilef, S. (2023) · Research Square · doi:10.21203/rs.3.rs-2526607/v1 · Cited by 1
Uma proposta para a compensação dinâmica de cargas desequilibradas
de Caravlho, L. T. (2017) · doi:10.14393/ufu.di.2018.1169
Optimized Device Loss and Capacitor Voltage Reduction of MMC-HVDC for Offshore Wind Farms
Li, J., Shi, E., Wu, X., Han, Z., Guo, X., & Guan, Y. (2019) · IEEE Sustainable Power and Energy Conference (iSPEC) · doi:10.1109/ispec48194.2019.8974963
“SIMULATIONS AND EXPERIMENTS System control strategy and circulating current control method in [14] are adopted for testing the proposed method.”
MethodSelf-citationEnhanced Control Algorithms in Permanent Magnet Synchronous Machines
Li, H. (2020) · Lincoln (University of Nebraska)
2018 Index IEEE Transactions on Power Delivery Vol. 33
(2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2018.2890521
Control of MMCs Under AC Grid Faults
Deng, F., Liu, C., & Chen, Z. (2023) · Wiley eBooks · doi:10.1002/9781119875635.ch6
Qian, S., Wang, F., Huang, H., Lin, J., Wang, Z., Kong, X., Liu, L., Tong, W., & Cui, G. (2024) · Systems Science & Control Engineering · doi:10.1080/21642583.2024.2409116
“Li et al. (2017) improved the operation of the MMC by injecting higher order harmonics into the circulating current based on reference calculations of transient information, which increased the bridge arm current peaks and DC current oscillations.”
Lavanya, K., Mary, K. A., & Garimella, S. (2025) · Physica Scripta · doi:10.1088/1402-4896/adb2f2
Thahab, R. T., & Al-Mhana, T. (2026) · Results in Engineering · doi:10.1016/j.rineng.2026.110427
Mohanty, P. K., Dash, J. R., Jena, P., Padhy, N. P., & Agarwal, P. (2025) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2025.3610754
“Furthermore, advanced control strategies have been proposed to optimize converter performance by actively managing SM capacitor voltage ripples through circulating current control, thereby reducing the output current’s total harmonic distortion (THD) [25], [26], [27].”
Analysis on Operational Characteristics of DC Hybrid SFCLCB With Self-Pickup Function
Choi, S.-S., Kim, S.-H., Park, C.-M., & Lim, S.-H. (2026) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2026.3664342
“Consequently, conversion losses caused by the power conversion equipment used in conventional AC systems are eliminated, making DC systems more efficient in terms of power loss [1], [2], [3], [4], [5].”
Metadata
- Authors
- Li, J., Konstantinou, G., Wickramasinghe, H. R., Pou, J., Wu, X., & Jin, X.
- Affiliations
- Beijing Jiaotong University (CN)
- UNSW Sydney (AU)
- Nanyang Technological University (SG)
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2018-06
- Volume
- 33
- Issue
- 3
- Pages
- 1257-1267
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2752484628
- Cited by
- 49
- References
- 31
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 4 · 2023: 5 · 2022: 3 · 2021: 4 · 2020: 7 · 2019: 13 · 2018: 5
- FWCI
- 3.07
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Locations
- IEEE Transactions on Power Delivery (publishedVersion)
- UNSWorks (University of New South Wales, Sydney, Australia) (submittedVersion, cc-by-nc-nd)
- UNSWorks (UNSW Sydney) (submittedVersion, cc-by-nc-nd)
- DR-NTU (Nanyang Technological University) (submittedVersion)
- Funders
- Australian Research Council's Discovery Early Career (DECRA - DE170100370)
- University of New South Wales
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Keywords
- modular multilevel converter, circulating current control, capacitor voltage ripple, unbalanced grid conditions, negative sequence current, harmonic injection, active and reactive power control, HVDC transmission
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.