The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
An Overview of Modular Multilevel Converters in HVDC Transmission Systems With STATCOM Operation During Pole-to-Pole DC Short Circuits
Abstract
Fault-current handling capability of the modular multilevel converters (MMCs) under dc-cable short-circuit conditions is a major concern for the MMC applications on the high-voltage direct-current (HVDC) transmission systems, where the MMCs based on half-bridge submodules (SMs) cannot block the fault currents to protect the converter devices. In this paper, a comprehensive review for the fault-ride-through capability of the HVDC transmission systems based on the MMCs adopting different SM schemes is presented, where the MMCs can block the fault currents and compensate the reactive currents to the electric grid during the dc faults. An analysis of the dc short-circuit faults in the MMC is introduced and then the operation principle of different SM circuits building the MMC for blocking the fault currents is highlighted. The fault-tolerant operation of these MMC schemes as static synchronous compensator to enhance the ac grid stability during the dc faults is also investigated. A comparison in terms of investment cost, loss, volume, and controllability for various MMC topologies is performed. Comprehensive simulation results for the most promising topologies of the MMC with a capability of fault-ride through under dc-fault conditions are finally presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Circuit Topologies, Modeling, Control Schemes, and Applications of Modular Multilevel Converters
Perez, M. A., Bernet, S., Rodriguez, J., Kouro, S., & Lizana, R. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2310127 · Cited by 1,346 · cited 1×
“The carrier-phase- or level-shift-pulsewidth modulation (CP/LS-PWM) technique is employed to generate the gating signals for the SMs of the CMC [85], [108]–[112].”
MethodModular Multilevel Converters for HVDC Applications: Review on Converter Cells and Functionalities
Nami, A., Liang, J., Dijkhuizen, F., & Demetriades, G. D. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2327641 · Cited by 1,042
A New AC/AC Multilevel Converter Family
Glinka, M., & Marquardt, R. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.843973 · Cited by 772
Design and Operation of a Hybrid Modular Multilevel Converter
Zeng, R., Xu, L., Yao, L., & Williams, B. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2320822 · Cited by 455
Modular Multilevel Converter topologies with DC-Short circuit current limitation
Marquardt, R. (2011) · 8th International Conference on Power Electronics - ECCE Asia · doi:10.1109/icpe.2011.5944451 · Cited by 413
Complete Loss and Thermal Model of Power Semiconductors Including Device Rating Information
Ma, K., Bahman, A. S., Beczkowski, S., & Blaabjerg, F. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2352341 · Cited by 199
Self-citationMerlin, M. M. C., Soto-Sanchez, D., Judge, P. D., Chaffey, G., Clemow, P., Green, T. C., Trainer, D. R., & Dyke, K. J. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2723948 · Cited by 142
Modular Multilevel Converter DC Fault Protection
Cwikowski, O., Wickramasinghe, H. R., Konstantinou, G., Pou, J., Barnes, M., & Shuttleworth, R. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2715833 · Cited by 118 · cited 3×
“The AAC arm consists of an active switch controlling the current direction and the FBSMs connected in series to produce the multilevel output voltages in positive and negative side [32], [69], [70].”
BackgroundMethodAn enhanced MMC topology with DC fault ride-through capability
Li, X., Liu, W., Song, Q., Rao, H., & Xu, S. (2013) · IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2013.6700152 · Cited by 92 · cited 1×
“6) The MMCs based on the three-level crossed-connected, five-level crossed-connected, clamp single SMs (CSSM) and unidirectional current H-bridge sub-modules, which are modified from the FBSM and CDSM, also possess a fault-current blocking capability [11], [88], [89].”
BackgroundLi, J., Konstantinou, G., Wickramasinghe, H. R., Pou, J., Wu, X., & Jin, X. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2747079 · Cited by 49
Cited by
Ruffing, P., Collath, N., Brantl, C., & Schnettler, A. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2018.2883861 · Cited by 48
Metadata
- Authors
- Nguyen, T. H., Hosani, K. A., Moursi, M. S. E., & Blaabjerg, F.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2019-05
- Volume
- 34
- Issue
- 5
- Pages
- 4137-4160
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2937779185
- Cited by
- 173
- References
- 10
- FWCI
- 7.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Overview of Modular Multilevel Converters in HVDC Transmission Systems With STATCOM Operation During Pole-to-Pole DC Short Circuits. https://app.cochat.ai/papers/10.1109/tpel.2018.2862247
- The paper
- Nguyen, T. H., Hosani, K. A., Moursi, M. S. E., & Blaabjerg, F. (2019). An Overview of Modular Multilevel Converters in HVDC Transmission Systems With STATCOM Operation During Pole-to-Pole DC Short Circuits. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2018.2862247
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.