The Predictive Closed-Loop Averaging Control of MMC Phase-Unit Losses Under Unbalanced Conditions
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
This paper introduces an averaging control strategy of the phase-unit losses of modular multilevel converters (MMCs). The quantitative analysis of the MMC phase-unit loss distribution under unbalanced ac conditions is carried out by investigating the individual component of the MMC arm currents. It shows that the unbalanced arm currents will result in unbalanced phase-unit losses. To address this issue, this paper proposes a predictive closed-loop-control-based zero-sequence voltage injection method that results in much averaged loss distribution under unbalanced ac conditions. The essence of the new method is that it adjusts the three-phase sinusoidal references so that the unbalanced arm currents are fully utilized to average phase-unit losses. This paper shows the effectiveness of the new approach by electromagnetic transient simulations on PSCAD/EMTDC.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
An innovative modular multilevel converter topology suitable for a wide power range
Lesnicar, A., & Marquardt, R. (2004) · 2003 IEEE Bologna Power Tech Conference Proceedings, · doi:10.1109/ptc.2003.1304403 · Cited by 2,908
VSC-Based HVDC Power Transmission Systems: An Overview
Flourentzou, N., Agelidis, V. G., & Demetriades, G. D. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2008441 · Cited by 2,216
Decoupled Double Synchronous Reference Frame PLL for Power Converters Control
Rodriguez, P., Pou, J., Bergas, J., Candela, J. I., Burgos, R. P., & Boroyevich, D. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890000 · Cited by 1,359
Modular Multilevel Converters for HVDC Applications: Review on Converter Cells and Functionalities
Nami, A., Liang, J., Dijkhuizen, F., & Demetriades, G. D. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2327641 · Cited by 1,042
Modulation, Losses, and Semiconductor Requirements of Modular Multilevel Converters
Rohner, S., Bernet, S., Hiller, M., & Sommer, R. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2031187 · Cited by 934
Marquardt, R. (2010) · The 2010 International Power Electronics Conference - ECCE ASIA - · doi:10.1109/ipec.2010.5544594 · Cited by 773
Dynamic Analysis of Modular Multilevel Converters
Harnefors, L., Antonopoulos, A., Norrga, S., Angquist, L., & Nee, H.-P. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194974 · Cited by 623
Guan, M., & Xu, Z. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2192752 · Cited by 549
A Steady-State Analysis Method for a Modular Multilevel Converter
Song, Q., Liu, W., Li, X., Rao, H., Xu, S., & Li, L. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2227818 · Cited by 503
Suppressing DC Voltage Ripples of MMC-HVDC Under Unbalanced Grid Conditions
Tu, Q., Xu, Z., Chang, Y., & Guan, L. (2012) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2196804 · Cited by 236
Cited by
Modular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“with MPC using a per-phase approach in which each phase is controlled separately [80], or using a three-phase approach that requires more calculations but improves the converter”
MethodAn Accelerated Distance Protection of Transmission Lines Emanating From MMC-HVdc Stations
Liang, Y., Huo, Y., & Zhao, F. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3058154 · Cited by 36
Ahmad, F., Adnan, M., Amin, A. A., & Khan, M. G. (2022) · Science Progress · doi:10.1177/00368504221118965 · Cited by 31
A STATCOM Based on a Three-Phase, Triple Inverter Modular Topology for Multilevel Operation
Pires, V. F., Cordeiro, A., Foito, D., & Silva, J. F. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2019.2923087 · Cited by 28
Hao, Q., Li, B., Sun, Y., Wu, L., & Wang, S. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2019.2935808 · Cited by 19
Metadata
- Authors
- Xu, J., Yu, Y., & Zhao, C.
- Affiliations
- North China Electric Power University (CN)
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2019-02
- Volume
- 34
- Issue
- 1
- Pages
- 198-207
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2891826046
- Cited by
- 14
- References
- 34
- Citations by year
- 2024: 1 · 2023: 4 · 2022: 3 · 2021: 3 · 2019: 3
- FWCI
- 0.57
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Power Delivery (publishedVersion)
- Funders
- National Key R&D Program of China (2018YFB0904600)
- National Natural Science Foundation of China (51607065, 51777072)
- Fundamental Research Funds
- Central Universities (2017MS002)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Keywords
- modular multilevel converter, unbalanced conditions, zero-sequence voltage injection, predictive control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Predictive Closed-Loop Averaging Control of MMC Phase-Unit Losses Under Unbalanced Conditions. https://app.cochat.ai/papers/10.1109/tpwrd.2018.2868772
- The paper
- Xu, J., Yu, Y., & Zhao, C. (2019). The Predictive Closed-Loop Averaging Control of MMC Phase-Unit Losses Under Unbalanced Conditions. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2018.2868772
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.