CoChat

Load Frequency Control of an Isolated Small-Hydro Power Plant With Reduced Dump Load

Doolla, S., Bhatti, T.S. · 2006 · IEEE Transactions on Power Systems
Cited by 112

The DOI matches its Crossref record.

Abstract

In this paper, a novel technique for load frequency control of an isolated small-hydro plant is presented. In general, the frequency is controlled by using a dump load, whose rating is equal to the rated power output of the plant. The new scheme proposed reduces the size of the dump load by controlling input power of the hydro power plant using on/off controls. The water flowing through the penstock is rerouted in smaller pipes, two or three fitted with motor operated valves. The opening or closing of the valves is achieved by on/off controls. The on/off control linearly raises or lowers the generation. A generalized transfer function model for the system is developed with an on/off control logic. Finally, the transient performance of the system is compared for the two-pipe case (50% dump load) and the three-pipe case (30% dump load)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tpwrs.2006.881157

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 112

Metadata

Authors
Doolla, S., & Bhatti, T. S.
Venue
IEEE Transactions on Power Systems
Published
2006-11
Volume
21
Issue
4
Pages
1912-1919
ISSN
0885-8950 (ISSN-L)
OpenAlex
W2117375092
Cited by
112
References
0
FWCI
0.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Load Frequency Control of an Isolated Small-Hydro Power Plant With Reduced Dump Load. https://app.cochat.ai/papers/10.1109/tpwrs.2006.881157
The paper
Doolla, S., & Bhatti, T. S. (2006). Load Frequency Control of an Isolated Small-Hydro Power Plant With Reduced Dump Load. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2006.881157

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.