The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Using Low Voltage MicroGrids for Service Restoration
Open accessAbstract
Under normal operating conditions, a MicroGrid is interconnected with the medium voltage network; however, in order to deal with black start and islanded operation following a general blackout, an emergency operation mode must be envisaged. A sequence of actions and conditions to be checked during the restoration stage are identified and tested through numerical simulation. Voltage and frequency control approaches, inverter control modes, and the need of storage devices are addressed in this paper in order to ensure system stability, achieve robustness of operation, and not jeopardize power quality during service restoration in the low voltage area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Defining Control Strategies for MicroGrids Islanded Operation
Lopes, J. A. P., Moreira, C. L., & Madureira, A. G. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.873018 · Cited by 2,312
Self-citationControl of parallel connected inverters in standalone AC supply systems
Chandorkar, M. C., Divan, D. M., & Adapa, R. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.195899 · Cited by 1,766
Flywheel batteries come around again
Hebner, R., Beno, J., & Walls, A. (2002) · IEEE Spectrum · doi:10.1109/6.993788 · Cited by 389
Control techniques of Dispersed Generators to improve the continuity of electricity supply
Barsali, S., Ceraolo, M., Pelacchi, P., & Poli, D. (2003) · 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309) · doi:10.1109/pesw.2002.985115 · Cited by 306
Power system restoration planning
Adibi, M. M., & Fink, L. H. (1994) · IEEE Transactions on Power Systems · doi:10.1109/59.317561 · Cited by 207
Applicability of droops in low voltage grids
Engler, A. (2006) · Fraunhofer-Publica (Fraunhofer-Gesellschaft) · doi:10.24406/publica-fhg-353843 · Cited by 144
Cited by
AC-microgrids versus DC-microgrids with distributed energy resources: A review
Justo, J. J., Mwasilu, F., Lee, J., & Jung, J.-W. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.03.067 · Cited by 1,245
Research on Resilience of Power Systems Under Natural Disasters—A Review
Wang, Y., Chen, C., Wang, J., & Baldick, R. (2016) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2015.2429656 · Cited by 1,116
“In [68], the authors describe the sequence of actions for a microgrid central controller (MGCC) to perform service restoration, which is briefly described as the following steps: 1) sectionalize the microgrid around each microsource (MS) with BS capability; 2) build the low voltage (LV) network utilizing storage devic…”
BackgroundDistributed Secondary Control for Islanded Microgrids—A Novel Approach
Shafiee, Q., Guerrero, J. M., & Vasquez, J. C. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2259506 · Cited by 1,069
Resilient Distribution System by Microgrids Formation After Natural Disasters
Chen, C., Wang, J., Qiu, F., & Zhao, D. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2429653 · Cited by 944
Energy Management in Autonomous Microgrid Using Stability-Constrained Droop Control of Inverters
Barklund, E., Pogaku, N., Prodanovic, M., Hernandez-Aramburo, C., & Green, T. C. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2001910 · Cited by 733
Metadata
- Authors
- Moreira, C. L., Resende, F. O., & Lopes, J. A. P.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2007-02
- Volume
- 22
- Issue
- 1
- Pages
- 395-403
- ISSN
- 0885-8950 (ISSN-L)
- OpenAlex
- W2107141928
- Cited by
- 290
- References
- 6
- FWCI
- 22.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.