The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Control of parallel connected inverters in standalone AC supply systems
Abstract
A scheme for controlling parallel-connected inverters in a standalone AC supply system is presented. This scheme is suitable for control of inverters in distributed source environments such as in isolated AC systems, large and distributed uninterruptible power supply (UPS) systems, photovoltaic systems connected to AC grids, and low-voltage DC power transmission meshes. A key feature of the control scheme is that it uses feedback of only those variables that can be measured locally at the inverter and does not need communication of control signals between the inverters. This is essential for the operation of large AC systems, where distances between inverters make communication impractical. It is also important in high-reliability UPS systems where system operation can be maintained in the face of a communication breakdown. Real and reactive power sharing between inverters can be achieved by controlling two independent quantities: the power angle and the fundamental inverter voltage magnitude. Simulation results are presented.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Neutral-Point-Clamped PWM Inverter
Nabae, A., Takahashi, I., & Akagi, H. (1981) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1981.4503992 · Cited by 5,139
A New Quick-Response and High-Efficiency Control Strategy of an Induction Motor
Takahashi, I., & Noguchi, T. (1986) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1986.4504799 · Cited by 3,407
Direct self-control (DSC) of inverter-fed induction machine
Depenbrock, M. (1988) · IEEE Transactions on Power Electronics · doi:10.1109/63.17963 · Cited by 1,705
University of Wisconsin, Madison
Cancian, M., Meyer, D. R., Arnesen, D. A., et al. (2005) · ADFL Bulletin · doi:10.1632/adfl.36.3.57 · Cited by 136
Cited by
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137
Guerrero, J. M., Matas, J., Garcia de Vicuna, L., Castilla, M., & Miret, J. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.892621 · Cited by 1,085
Control Strategy for Flexible Microgrid Based on Parallel Line-Interactive UPS Systems
Guerrero, J. M., Vasquez, J. C., Matas, J., Castilla, M., & de Vicuna, L. G. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2009274 · Cited by 788
Frequency Stability of Synchronous Machines and Grid-Forming Power Converters
Tayyebi, A., Gross, D., Anta, A., Kupzog, F., & Dorfler, F. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2966524 · Cited by 442
Metadata
- Authors
- Chandorkar, M. C., Divan, D. M., & Adapa, R.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 1993
- Volume
- 29
- Issue
- 1
- Pages
- 136-143
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2162156389
- Cited by
- 1,766
- References
- 4
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Control of parallel connected inverters in standalone AC supply systems. https://app.cochat.ai/papers/10.1109/28.195899
- The paper
- Chandorkar, M. C., Divan, D. M., & Adapa, R. (1993). Control of parallel connected inverters in standalone AC supply systems. IEEE Transactions on Industry Applications. https://doi.org/10.1109/28.195899
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.