The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Grid Integration of Large DFIG-Based Wind Farms Using VSC Transmission
Abstract
This paper describes the use of voltage source converter (VSC)-based HVDC transmission system (VSC transmission) technology for connecting large doubly fed induction generator (DFIG)-based wind farms over long distance. The operation principles of the proposed system are described, and new control strategies for normal and grid fault conditions are proposed. To obtain smooth operation, the wind farm side VSC (WFVSC) is controlled as an infinite voltage source that automatically absorbs power generated by the wind farm and maintains a stable local ac network. Fault ride through of the system during grid ac faults is achieved by ensuring automatic power balancing through frequency modulation using WFVSC and frequency control using DFIG. PSCAD/EMTDC simulations are presented to demonstrate robust performance during wind speed and power variations and to validate the fault ride through capability of the proposed system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pena, R., Clare, J. C., & Asher, G. M. (1996) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:19960288 · Cited by 2,759
Optimal acquisition and aggregation of offshore wind power by multiterminal voltage-source HVDC
Lu, W., & Ooi, B.-T. (2003) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2002.803826 · Cited by 333
VSC Transmission Operating Under Unbalanced AC Conditions—Analysis and Control Design
Xu, L., Andersen, B. R., & Cartwright, P. (2005) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2004.835032 · Cited by 231
Self-citationTopologies for VSC transmission
Andersen, B. R., Xu, L., Cartwright, P., & Horton, P. J. (2002) · Power Engineering Journal · doi:10.1049/pe:20020307 · Cited by 195
Self-citationOptimal Integration of an Offshore Wind Farm to a Weak AC Grid
Koutiva, X. I., Vrionis, T. D., Vovos, N. A., & Giannakopoulos, G. B. (2006) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2005.859275 · Cited by 90
Cited by
VSC-Based HVDC Power Transmission Systems: An Overview
Flourentzou, N., Agelidis, V. G., & Demetriades, G. D. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2008441 · Cited by 2,216
She, X., Huang, A. Q., Wang, F., & Burgos, R. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2216245 · Cited by 161
Metadata
- Authors
- Xu, L., Yao, L., & Sasse, C.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2007-08
- Volume
- 22
- Issue
- 3
- Pages
- 976-984
- ISSN
- 0885-8950 (ISSN-L)
- OpenAlex
- W2146878104
- Cited by
- 428
- References
- 5
- FWCI
- 15.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Grid Integration of Large DFIG-Based Wind Farms Using VSC Transmission. https://app.cochat.ai/papers/10.1109/tpwrs.2007.901306
- The paper
- Xu, L., Yao, L., & Sasse, C. (2007). Grid Integration of Large DFIG-Based Wind Farms Using VSC Transmission. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2007.901306
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.