Fault Ride-Through of Large Wind Farms Using Series Dynamic Braking Resistors (March 2007)
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Fault ride-through (FRT) is required for large wind farms in most power systems. Fixed speed wind turbines (FSWTs) are a diminishing but significant sector in the fast-growing wind turbine (WT) market. State-of-art techniques applied to meet grid requirements for FSWT wind farms are blade pitching and dynamic reactive power compensation (RPC). Blade pitching is constrained by the onerous mechanical loads imposed on a wind turbine during rapid power restoration. Dynamic RPC is constrained by its high capital cost. These present technologies can therefore be limiting, especially when connecting to smaller power systems. A novel alternative technology is proposed that inserts series resistance into the generation circuit. The series dynamic braking resistor (SDBR) dissipates active power and boosts generator voltage, potentially displacing the need for pitch control and dynamic RPC. This paper uses a representative wind farm model to study the beneficial effect of SDBR compared to dynamic RPC. This is achieved by quasi-steady-state characterization and transient FRT stability simulations. The analysis shows that SDBR can substantially improve the FRT performance of a FSWT wind farm. It also shows that a small resistance, inserted for less than one
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2005) · Wiley eBooks · doi:10.1002/0470012684 · Cited by 2,915
Wind Energy Explained: Theory, Design and Application
Manwell, J. F., McGowan, J. G., & Rogers, A. L. (2002) · Wiley eBooks · doi:10.1002/0470846127 · Cited by 1,158
Grid Code, high and extra high voltage
Netz, E. O. (2006) · Medical Entomology and Zoology · Cited by 835
Conceptual Survey of Generators and Power Electronics for Wind Turbines
Hansen, L. H., Helle, L., Blaabjerg, F., Ritchie, E., Munk‐Nielsen, S., Bindner, H. W., Sørensen, P. E., Bak‐Jensen, B., Daniela, A., Peter, H., et al. (2001) · Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU) · Cited by 417
Application of a 138 kV 200 MW braking resistor
Peelo, D. F., Hein, D., & Peretti, F. (1994) · Power Engineering Journal · doi:10.1049/pe:19940408 · Cited by 14 · cited 1×
“Previous DBR topologies proposed by Wu [11] and Freitus [12] for wind farm stability have a shunt-connected topology, in the manner previously applied to improve transmission and synchronous generator stability [ 13 ], [14].”
Method
Cited by
High-power wind energy conversion systems: State-of-the-art and emerging technologies
Yaramasu, V., Wu, B., Sen, P. C., Kouro, S., & Narimani, M. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2378692 · Cited by 991
Mohseni, M., & Islam, S. M. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.03.039 · Cited by 327
Yang, J., Fletcher, J. E., & O'Reilly, J. (2010) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2009.2037970 · Cited by 308
Wind Farms Fault Ride Through Using DFIG With New Protection Scheme
Okedu, K. E., Muyeen, S. M., Takahashi, R., & Tamura, J. (2012) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2011.2175756 · Cited by 228
Impact of renewable generation on voltage control in distribution systems
Petinrin, J. O., & Shaabanb, M. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.06.073 · Cited by 198
Metadata
- Authors
- Causebrook, A., Atkinson, D. J., & Jack, A. G.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2007-08
- Volume
- 22
- Issue
- 3
- Pages
- 966-975
- ISSN
- 0885-8950 (ISSN-L)
- OpenAlex
- W2132063141
- Cited by
- 230
- References
- 5
- FWCI
- 11.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.