The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Wind Farms Fault Ride Through Using DFIG With New Protection Scheme
Abstract
This paper proposes a control strategy of doubly fed induction generators (DFIGs) with new protection schemes for enhancing fault ride through capability of wind farms composed of DFIGs and induction generators (IGs). Since the DFIGs will be stressed or overloaded in the process of stabilizing the wind farm during a grid fault, it is paramount to consider a protection scheme for the DFIG, in order to protect its power converters. Two schemes, the dc-link chopper-controlled braking resistor with the supplementary rotor current (SRC) control of the rotor side converter of the DFIG and series dynamic braking resistor (SDBR) connected to the stator of the DFIG, are proposed and compared. Merits and drawbacks of both schemes are highlighted as well. The simulation results in power system computer aided design and electromagnetic transient including DC (PSCAD/EMTDC) show that the two proposed schemes can eliminate the need for an expensive crowbar switch in the rotor circuit, because both could limit the rotor current of the DFIG within its nominal value during a grid fault. Finally, considering the overall system performance, the latter is recommended.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic Behavior of the Doubly Fed Induction Generator During Three-Phase Voltage Dips
LÓpez, J., Sanchis, P., Roboam, X., & Marroyo, L. (2007) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.878241 · Cited by 550
Cited by
The state of the art of wind energy conversion systems and technologies: A review
Cheng, M., & Zhu, Y. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2014.08.037 · Cited by 600
A review of control techniques for inverter-based distributed energy resources applications
Hasheminasab, S., Alzayed, M., & Chaoui, H. (2024) · Energies · doi:10.3390/en17122940 · Cited by 56
Metadata
- Authors
- Okedu, K. E., Muyeen, S. M., Takahashi, R., & Tamura, J.
- Venue
- IEEE Transactions on Sustainable Energy
- Published
- 2012-04
- Volume
- 3
- Issue
- 2
- Pages
- 242-254
- ISSN
- 1949-3029 (ISSN-L)
- 1949-3037
- OpenAlex
- W2106119713
- Cited by
- 228
- References
- 1
- FWCI
- 8.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wind Farms Fault Ride Through Using DFIG With New Protection Scheme. https://app.cochat.ai/papers/10.1109/tste.2011.2175756
- The paper
- Okedu, K. E., Muyeen, S. M., Takahashi, R., & Tamura, J. (2012). Wind Farms Fault Ride Through Using DFIG With New Protection Scheme. IEEE Transactions on Sustainable Energy. https://doi.org/10.1109/tste.2011.2175756
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.