Voltage and Transient Stability Support by Wind Farms Complying With the E.ON Netz Grid Code
Abstract
In this paper, the impact of the response of a wind farm (WF) on the operation of a nearby grid is investigated during network disturbances. Only modern variable speed wind turbines are treated in this work. The new E.ON Netz fault response code for WF is taken as the base case for the study. The results found in this paper are that the performance of the used Cigre 32-bus test system during disturbances is improved when the WF is complying with the E.ON code compared to the traditional unity power factor operation. Further improvements are found when the slope of the reactive current support line is increased from the E.ON specified value. In addition, a larger converter of a variable speed wind turbine is exploited that is to be used in order to improve the stability of a nearby grid by extending the reactive current support. By doing so, it is shown in this paper that the voltage profile at the point of common coupling (pcc) as well as the transient stability of the grid are improved compared to the original E.ON code, in addition to the improvements already achieved by using the E.ON code in its original form. Finally, regarding the utilization of a larger converter, it is important to point out that the possible reactive power in-feed into the pcc from an offshore WF decreases with increasing cable length during network faults, making it difficult to support the grid with extra reactive power during disturbances.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
A review of grid code technical requirements for wind farms
Tsili, M., & Papathanassiou, S. (2009) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2008.0070 · Cited by 1,373
Shair, J., Li, H., Hu, J., & Xie, X. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111111 · Cited by 433
Taul, M. G., Wang, X., Davari, P., & Blaabjerg, F. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2892142 · Cited by 415
Stochastic Optimization Model to Study the Operational Impacts of High Wind Penetrations in Ireland
Meibom, P., Barth, R., Hasche, B., Brand, H., Weber, C., & O'Malley, M. (2011) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2070848 · Cited by 344
Mohseni, M., & Islam, S. M. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.03.039 · Cited by 327
She, X., Huang, A. Q., Wang, F., & Burgos, R. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2216245 · Cited by 161
“Reactive power compensators, such as STATCOM, are hence good solutions for regulating the PCC voltage [3]–[8], and it is also shown in Fig.”
BackgroundDong, Y., Yang, H., Li, W., & He, X. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2833019 · Cited by 39
Metadata
- Authors
- Ullah, N. R., Thiringer, T., & Karlsson, D.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2007-11
- Volume
- 22
- Issue
- 4
- Pages
- 1647-1656
- ISSN
- 0885-8950 (ISSN-L)
- OpenAlex
- W2142500604
- Cited by
- 180
- References
- 0
- FWCI
- 9.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.