Line Outage Detection Using Phasor Angle Measurements
Abstract
Although phasor measurement units (PMUs) have become increasingly widespread throughout power networks, the buses monitored by PMUs still constitute a very small percentage of the total number of system buses. Our research explores methods to derive useful information from PMU data in spite of this limited coverage. In particular, we have developed an algorithm which uses known system topology information, together with PMU phasor angle measurements, to detect system line outages. In addition to determining the outaged line, the algorithm also provides an estimate of the pre-outage flow on the outaged line. To demonstrate the effectiveness of our approach, the algorithm is demonstrated using simulated and real PMU data from two systems—a 37-bus study case and the TVA control area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power Generation, Operation, and Control
Wood, A. J., & Wollenberg, B. F. (1984) · Cited by 8,303
Computer Vision: A Modern Approach
Forsyth, D. A., & Ponce, J. (2002) · Cited by 3,739
Power System Analysis and Design
Glover, J. D., & Sarma, M. S. (2007) · Cited by 1,470
Hill, P. G. (1977) · Cited by 1,394
Electric power system state estimation
Monticelli, A. (2000) · Proceedings of the IEEE · doi:10.1109/5.824004 · Cited by 767
(2016) · Elsevier eBooks · doi:10.1016/c2013-0-19116-7 · Cited by 689
Power System Frequency Monitoring Network (FNET) Implementation
Zhong, Z., Xu, C., Billian, B. J., Zhang, L., Tsai, S.-J. S., Conners, R. W., Centeno, V. A., Phadke, A. G., & Liu, Y. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.857386 · Cited by 346
An Online Dynamic Security Assessment Scheme Using Phasor Measurements and Decision Trees
Sun, K., Likhate, S., Vittal, V., Kolluri, V. S., & Mandal, S. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.908476 · Cited by 337
Computational Methods for Electric Power Systems
Grigsby, L. L. (2007) · CRC Press eBooks · doi:10.1201/9781420009231-10 · Cited by 122
Nicholson, W. K. (2001) · Cited by 96
Cited by
Smart Grid — The New and Improved Power Grid: A Survey
Fang, X., Misra, S., Xue, G., & Yang, D. (2012) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2011.101911.00087 · Cited by 3,405
Synchrophasor Measurement Technology in Power Systems: Panorama and State-of-the-Art
Aminifar, F., Fotuhi-Firuzabad, M., Safdarian, A., Davoudi, A., & Shahidehpour, M. (2014) · IEEE Access · doi:10.1109/access.2015.2389659 · Cited by 261
False data attack models, impact analyses and defense strategies in the electricity grid
Liu, X., & Li, Z. (2017) · The Electricity Journal · doi:10.1016/j.tej.2017.04.001 · Cited by 57
Efficient neural network architecture for topology identification in smart grid
Zhao, Y., Chen, J., & Poor, H. V. (2016) · 2016 IEEE Global Conference on Signal and Information Processing (GlobalSIP) · doi:10.1109/globalsip.2016.7905955 · Cited by 12
Metadata
- Authors
- Tate, J. E., & Overbye, T. J.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2008-11
- Volume
- 23
- Issue
- 4
- Pages
- 1644-1652
- ISSN
- 0885-8950 (ISSN-L)
- OpenAlex
- W2106441659
- Cited by
- 306
- References
- 10
- FWCI
- 6.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Line Outage Detection Using Phasor Angle Measurements. https://app.cochat.ai/papers/10.1109/tpwrs.2008.2004826
- The paper
- Tate, J. E., & Overbye, T. J. (2008). Line Outage Detection Using Phasor Angle Measurements. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2008.2004826
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.