The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Kinetic Energy of Wind-Turbine Generators for System Frequency Support
Abstract
As wind power penetration increases and fossil plants are retired, it is feared that there will be insufficient kinetic energy (KE) from the plants to support the system frequency. This paper shows the fear is groundless because the high inertias (Hcong 4 seconds) of wind turbine-generators (WTGs) can be integrated to provide frequency support during generation outage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wind Turbines Emulating Inertia and Supporting Primary Frequency Control
Morren, J., de Haan, S. W. H., Kling, W. L., & Ferreira, J. A. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.861956 · Cited by 1,263
Frequency Control and Wind Turbine Technologies
Lalor, G., Mullane, A., & O'Malley, M. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.857393 · Cited by 698
Ekanayake, J., & Jenkins, N. (2004) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.827712 · Cited by 641
Participation of Doubly Fed Induction Wind Generators in System Frequency Regulation
de Almeida, R. G., & Pecas Lopes, J. A. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.901096 · Cited by 576
Control of DFIG-Based Wind Generation for Power Network Support
Hughes, F. M., Anaya-Lara, O., Jenkins, N., & Strbac, G. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.857275 · Cited by 415
Optimal acquisition and aggregation of offshore wind power by multiterminal voltage-source HVDC
Lu, W., & Ooi, B.-T. (2003) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2002.803826 · Cited by 333
Self-citationKinetic energy and frequency response comparison for renewable generation systems
Mullane, A., Bryans, G., & O’Malley, M. (2005) · International Conference on Future Power Systems · doi:10.1109/fps.2005.204252 · Cited by 45
Cited by
High-power wind energy conversion systems: State-of-the-art and emerging technologies
Yaramasu, V., Wu, B., Sen, P. C., Kouro, S., & Narimani, M. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2378692 · Cited by 991
Inertia response and frequency control techniques for renewable energy sources: A review
Dreidy, M., Mokhlis, H., & Mekhilef, S. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.11.170 · Cited by 853
The Relevance of Inertia in Power Systems
Tielens, P., & Van Hertem, D. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.11.016 · Cited by 809
Pandey, S. K., Mohanty, S. R., & Kishor, N. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.04.029 · Cited by 561
Future low-inertia power systems: Requirements, issues, and solutions - A review
Ratnam, K. S., Palanisamy, K., & Yang, G. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.109773 · Cited by 474
Metadata
- Authors
- Keung, P.-K., Li, P., Banakar, H., & Ooi, B. T.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2009-02
- Volume
- 24
- Issue
- 1
- Pages
- 279-287
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2125656363
- Cited by
- 349
- References
- 7
- FWCI
- 8.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Kinetic Energy of Wind-Turbine Generators for System Frequency Support. https://app.cochat.ai/papers/10.1109/tpwrs.2008.2004827
- The paper
- Keung, P.-K., Li, P., Banakar, H., & Ooi, B. T. (2009). Kinetic Energy of Wind-Turbine Generators for System Frequency Support. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2008.2004827
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.