Models for Quantifying the Economic Benefits of Distributed Generation
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We examine some of the most important economic benefits brought about by distributed generation technologies to the distribution utility and the power system. Models are developed that allow the quantification of those benefits in economic terms. In some cases, industry regulators or utilities charge connection fees to the owners of distributed generators, even if they are saving the local utility considerable amounts of money every year in deferred network upgrades, reduced losses, avoided wholesale market purchases and others. Efficient economic systems dictate that a proper share of the indirect benefits created by a given economic activity leads to overall optimal independent decision-making by its participants. Quantifying and allocating the benefits of distributed generation to the owners improves the economic performance of their investments and encourages the implementation of those distributed generation applications most valuable to the system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the Quantification of the Network Capacity Deferral Value of Distributed Generation
Gil, H. A., & Joos, G. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.881158 · Cited by 180 · cited 2×
“As previously mentioned, in our own research on the quantification of this benefit, we have obtained figures of up to 1200 $/kVA depending on the location of the DG and the load growth rate [6].”
Self-citationWerven, M. J. N. V., & Scheepers, M. J. J. (2005) · International Conference on Future Power Systems · doi:10.1109/fps.2005.204259 · Cited by 47 · cited 1×
“The competitive strength of DG has been seriously recognized by the industry [8].”
Cited by
Integration of renewable distributed generators into the distribution system: a review
Adefarati, T., & Bansal, R. C. (2016) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2015.0378 · Cited by 583
AC and DC technology in microgrids: A review
Planas, E., Andreu, J., Gárate, J. I., Martínez de Alegría, I., & Ibarra, E. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.11.067 · Cited by 500
Mahmud, N., & Zahedi, A. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.06.030 · Cited by 377
Zeraati, M., Hamedani Golshan, M. E., & Guerrero, J. M. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2749623 · Cited by 232
“Therefore, the total installed capacity of photovoltaic (PV) and the number of plug-in electric vehicles (PEVs) increase dramatically in low voltage distribution networks (LVDNs) [1] and thus distribution network operators (DNOs) face new operational challenges [2].”
Marnay, C., Chatzivasileiadis, S., Abbey, C., Iravani, R., Joos, G., Lombardi, P., Mancarella, P., & von Appen, J. (2015) · 2015 International Symposium on Smart Electric Distribution Systems and Technologies (EDST) · doi:10.1109/sedst.2015.7315197 · Cited by 190
Microgrids: Energy management by strategic deployment of DERs—A comprehensive survey
Basu, A. K., Chowdhury, S. P., Chowdhury, S., & Paul, S. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2011.07.116 · Cited by 181
Planning in Microgrids With Conservation of Voltage Reduction
Gheydi, M., Nouri, A., & Ghadimi, N. (2018) · IEEE Systems Journal · doi:10.1109/jsyst.2016.2633512 · Cited by 160
Marra, F., Fawzy, Y. T., Bulo, T., & Blazic, B. (2012) · 2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe) · doi:10.1109/isgteurope.2012.6465690 · Cited by 53
Metadata
- Authors
- Gil, H. A., & Joos, G.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2008-05
- Volume
- 23
- Issue
- 2
- Pages
- 327-335
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2149177425
- Cited by
- 194
- References
- 2
- FWCI
- 11.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.