An Improved OPA Model and Blackout Risk Assessment
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
The ORNL-PSerc-Alaska (OPA) model is a blackout model proposed by researchers at Oak Ridge National Laboratory (ORNL), Power System Engineering Research Center of Wisconsin University (PSerc), and Alaska University (Alaska). Although the OPA model is a landmark study, it has two limitations. First, there is a significant difference between simulation and practice in transmission line outage and update; and second, the simulation of cascading failure and the probability distribution of blackout size are in general not accurate enough. Hence, an improved OPA model is proposed in this paper to address these limitations. The proposed model contains two layers of iteration. The inner iteration describes the fast dynamics of the system and considers the influence of power flow, dispatching, automation, relay protection, and so on. The outer iteration describes the slow overall system evolution and is concerned with the update of the power grid, operation modes and planning. Such a model can be applied to practical large-scale systems. Furthermore, based on the Value at Risk (VaR) and Conditional Value at Risk (CVaR), two new complementary blackout risk indices are defined, which reveal critical characteristics of blackouts and are used to evaluate security levels of power systems. The effectiveness of the improved OPA model is verified by the simulations concerning the Northeast Power Grid of China.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Artzner, P., Delbaen, F., Eber, J., & Heath, D. (1999) · Mathematical Finance · doi:10.1111/1467-9965.00068 · Cited by 8,806 · cited 1×
“One is that it does not satisfy the Coherent Axiom [24], [25]; the other is that the tail-loss measurement is not sufficient.”
BackgroundOptimization of conditional value-at-risk
Rockafellar, R. T., & Uryasev, S. (2000) · The Journal of Risk · doi:10.21314/jor.2000.038 · Cited by 6,725 · cited 1×
“Rockafeller and Uryasev proposed the CVaR to deal with the shortcomings of the VaR [26].”
BackgroundCarreras, B. A., Lynch, V. E., Dobson, I., & Newman, D. E. (2002) · Chaos: An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.1505810 · Cited by 542 · cited 2×
“Paper [14] discovers two critical points, which were further studied in [15].”
BackgroundResultCascading dynamics and mitigation assessment in power system disturbances via a hidden failure model
Chen, J., Thorp, J. S., & Dobson, I. (2005) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2004.12.003 · Cited by 501 · cited 2×
“Several models have been proposed in order to study the cascading failure, such as CASCADE model [6], Branching process model [7], Hidden failure model [ 8 ]‐[10], OPA model”
BackgroundMethodEvidence for Self-Organized Criticality in a Time Series of Electric Power System Blackouts
Carreras, B. A., Newman, D. E., Dobson, I., & Poole, A. B. (2004) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2004.834513 · Cited by 373 · cited 1×
“In this context, methods based on the complex system theory have become promising in the analysis of power system blackouts [1]–[5].”
MethodCriticality in a cascading failure blackout model
Nedic, D. P., Dobson, I., Kirschen, D. S., Carreras, B. A., & Lynch, V. E. (2006) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2006.03.006 · Cited by 336 · cited 1×
“2016521 [11], and the Manchester model [12].”
Expose hidden failures to prevent cascading outages [in power systems]
Phadke, A. G., & Thorp, J. S. (1996) · IEEE Computer Applications in Power · doi:10.1109/67.526849 · Cited by 247 · cited 1×
“Several models have been proposed in order to study the cascading failure, such as CASCADE model [6], Branching process model [7], Hidden failure model [8]–[10], OPA model”
MethodComplex dynamics of blackouts in power transmission systems
Carreras, B. A., Lynch, V. E., Dobson, I., & Newman, D. E. (2004) · Chaos: An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.1781391 · Cited by 234 · cited 2×
“Motivated by the results in [14] and [15], the authors of [16] carried out the study on the complex dynamics of blackouts.”
BackgroundResultMei, S., Ni, Y., Wang, G., & Wu, S. (2008) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2008.2002295 · Cited by 166
Self-citationEvidence for self-organized criticality in electric power system blackouts
Carreras, B. A., Newman, D. E., Dobson, I., & Poole, A. B. (2005) · Hawaii International Conference on System Sciences (HICSS) · doi:10.1109/hicss.2001.926273 · Cited by 147
Blackout mitigation assessment in power transmission systems
Carreras, B. A., Lynch, V. E., Newman, D. E., & Dobson, I. (2003) · Hawaii International Conference on System Sciences (HICSS) · doi:10.1109/hicss.2003.1173911 · Cited by 93
Initial evidence for self-organized criticality in electric power system blackouts
Carreras, B. A., Newman, D. E., Dobson, I., & Poole, A. B. (2005) · Hawaii International Conference on System Sciences (HICSS) · doi:10.1109/hicss.2000.926768 · Cited by 88
Analysis of electric power system disturbance data
Chen, J., Thorp, J. S., & Parashar, M. (2005) · Hawaii International Conference on System Sciences (HICSS) · doi:10.1109/hicss.2001.926277 · Cited by 66
Blackout Model Based on OPF and its Self-organized Criticality
Mei, S., Yadana, Weng, X.-F., & Xue, A. (2006) · Chinese Control Conference (CCC) · doi:10.1109/chicc.2006.280819 · Cited by 54 · cited 2×
“Later the model in [17] was further developed in [18] to include a voltage stability analysis function.”
MethodSelf-citation
Cited by
Do topological models provide good information about electricity infrastructure vulnerability?
Hines, P., Cotilla-Sanchez, E., & Blumsack, S. (2010) · Chaos: An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.3489887 · Cited by 356
Toward a consensus on the definition and taxonomy of power system resilience
Gholami, A., Shekari, T., Amirioun, M. H., Aminifar, F., Amini, M. H., & Sargolzaei, A. (2018) · IEEE Access · doi:10.1109/access.2018.2845378 · Cited by 294
Benchmarking and Validation of Cascading Failure Analysis Tools
Bialek, J., Ciapessoni, E., Cirio, D., Cotilla-Sanchez, E., Dent, C., Dobson, I., Henneaux, P., Hines, P., Jardim, J., Miller, S., et al. (2016) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2016.2518660 · Cited by 167
“3) NPGC Test Case: The NPGC (Northeast Power Grid of China) system consists of Heilongjiang, Jilin, Liaoning, and the northern part of Inner Mongolia of China [103], [124], [125].”
BackgroundMethod
Metadata
- Authors
- Mei, S., He, F., Zhang, X., Wu, S., & Wang, G.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2009-05
- Volume
- 24
- Issue
- 2
- Pages
- 814-823
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2120483528
- Cited by
- 251
- References
- 14
- FWCI
- 5.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.