The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
DC Power Flow Revisited
Abstract
Linear MW-only ldquodcrdquo network power flow models are in widespread and even increasing use, particularly in congestion-constrained market applications. Many versions of these approximate models are possible. When their MW flows are reasonably correct (and this is by no means assured), they can often offer compelling advantages. Given their considerable importance in today's electric power industry, dc models merit closer scrutiny. This paper attempts such a re-examination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power Generation, Operation, and Control
Wood, A. J., & Wollenberg, B. F. (1984) · Cited by 8,303
Market Operations in Electric Power Systems: Forecasting, Scheduling, and Risk Management
Shahidehpour, M., Yamin, H., & Li, Z. (2002) · Wiley eBooks · doi:10.1002/047122412x · Cited by 1,616
Review of load-flow calculation methods
Stott, B. (1974) · Proceedings of the IEEE · doi:10.1109/proc.1974.9544 · Cited by 747
Self-citationElectric Energy Systems : Analysis and Operation
Gómez‐Expósito, A., Conejo, A. J., & Cañizares, C. A. (2008) · Cited by 519
Usefulness of DC power flow for active power flow analysis
Purchala, K., Meeus, L., Van Dommelen, D., & Belmans, R. (2005) · IEEE Power Engineering Society General Meeting, 2005 · doi:10.1109/pes.2005.1489581 · Cited by 386
A comparison of the AC and DC power flow models for LMP calculations
Overbye, T. J., Cheng, X., & Sun, Y. (2004) · 37th Annual Hawaii International Conference on System Sciences, 2004. Proceedings of the · doi:10.1109/hicss.2004.1265164 · Cited by 329
Cited by
Branch Flow Model: Relaxations and Convexification—Part I
Farivar, M., & Low, S. H. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2255317 · Cited by 1,541
“I. INTRODUCTION”
A Survey of Distributed Optimization and Control Algorithms for Electric Power Systems
Molzahn, D. K., Dorfler, F., Sandberg, H., Low, S. H., Chakrabarti, S., Baldick, R., & Lavaei, J. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2720471 · Cited by 1,273
Convex Relaxation of Optimal Power Flow—Part I: Formulations and Equivalence
Low, S. H. (2014) · IEEE Transactions on Control of Network Systems · doi:10.1109/tcns.2014.2309732 · Cited by 929
Ringkjøb, H.-K., Haugan, P. M., & Solbrekke, I. M. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.08.002 · Cited by 760
PyPSA: Python for Power System Analysis
Brown, T., Hörsch, J., & Schlachtberger, D. (2018) · Journal of Open Research Software · doi:10.5334/jors.188 · Cited by 575
Metadata
- Authors
- Stott, B., Jardim, J., & Alsac, O.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2009-08
- Volume
- 24
- Issue
- 3
- Pages
- 1290-1300
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2168283238
- Cited by
- 1,052
- References
- 6
- FWCI
- 14.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.