The DOI matches its Crossref record.
Multivariable Servomechanism Controller for Autonomous Operation of a Distributed Generation Unit: Design and Performance Evaluation
Abstract
A linear time-invariant (LTI) robust servomechanism controller for islanded (autonomous) operation of a distributed generation (DG) unit and its local load is proposed. The DG unit utilizes a voltage-sourced converter (VSC) as the interface medium. The controller design is obtained by introducing a new optimal controller design procedure, in conjunction with a proposed non-conservative robustness constraint. The proposed controller utilizes 1) an internal oscillator for frequency control and 2) a robust servomechanism controller (RSC) to regulate the island voltage. Despite uncertainty of the load parameters, the proposed controller guarantees robust stability and pre-specified performance criteria, e.g., fast transient response and zero steady-state error. The theoretical aspects of the proposed robust servomechanism controller including the existence conditions, design of the controller, and robust stability analysis of the closed-loop system are studied. Moreover, the performance of the robust servomechanism controller based on 1) simulation studies in the MATLAB software environment, and 2) experiments in a laboratory-scale setup, is presented in this paper. In particular, reference signal tracking and robustness of the closed-loop system with respect to the load parameter uncertainty are investigated. Both computer simulation studies and experimental results confirm that the proposed robust controller provides the specified performance characteristics of the closed-loop system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137
Self-citationBasak, P., Chowdhury, S., Halder nee Dey, S., & Chowdhury, S. P. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.05.043 · Cited by 508
A survey on control issues in renewable energy integration and microgrid
Badal, F. R., Das, P., Sarker, S. K., & Das, S. K. (2019) · Protection and Control of Modern Power Systems · doi:10.1186/s41601-019-0122-8 · Cited by 357
Mohamed, Y. A.-R. I., & Radwan, A. A. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2136362 · Cited by 309
Modeling and control of microgrid: An overview
Mahmoud, M. S., Azher Hussain, S., & Abido, M. A. (2014) · Journal of the Franklin Institute · doi:10.1016/j.jfranklin.2014.01.016 · Cited by 279
Metadata
- Authors
- Karimi, H., Davison, E. J., & Iravani, R.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2010-05
- Volume
- 25
- Issue
- 2
- Pages
- 853-865
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2128901178
- Cited by
- 166
- References
- 0
- FWCI
- 13.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multivariable Servomechanism Controller for Autonomous Operation of a Distributed Generation Unit: Design and Performance Evaluation. https://app.cochat.ai/papers/10.1109/tpwrs.2009.2031441
- The paper
- Karimi, H., Davison, E. J., & Iravani, R. (2010). Multivariable Servomechanism Controller for Autonomous Operation of a Distributed Generation Unit: Design and Performance Evaluation. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2009.2031441
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.