The DOI matches its Crossref record.
Sparse Overcomplete Representations for Efficient Identification of Power Line Outages
Abstract
Fast and accurate unveiling of power-line outages is of paramount importance not only for preventing faults that may lead to blackouts, but also for routine monitoring and control tasks of the smart grid, including state estimation and optimal power flow. Existing approaches are either challenged by the combinatorial complexity issues involved and are thus limited to identifying single and double line-outages or they invoke less pragmatic assumptions such as conditionally independent phasor angle measurements available across the grid. Using only a subset of voltage phasor angle data, the present paper develops a near real-time algorithm for identifying multiple line outages at the affordable complexity of solving a sparse signal reconstruction problem via either greedy steps or coordinate descent iterations. Recognizing that the number of line outages is a small fraction of the total number of lines, the novel approach relies on reformulating the DC linear power flow model as a sparse overcomplete expansion and leveraging contemporary advances in compressive sampling and variable selection. This sparse representation can also be extended to incorporate available information on the internal system and more general line-parameter faults. Analysis and simulated tests on 118-, 300-, and 2383-bus systems confirm the effectiveness of identifying sparse power line outages.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Synchrophasor Measurement Technology in Power Systems: Panorama and State-of-the-Art
Aminifar, F., Fotuhi-Firuzabad, M., Safdarian, A., Davoudi, A., & Shahidehpour, M. (2014) · IEEE Access · doi:10.1109/access.2015.2389659 · Cited by 261
Resilience of Energy Infrastructure and Services: Modeling, Data Analytics, and Metrics
Ji, C., Wei, Y., & Poor, H. V. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2698262 · Cited by 91
False data attack models, impact analyses and defense strategies in the electricity grid
Liu, X., & Li, Z. (2017) · The Electricity Journal · doi:10.1016/j.tej.2017.04.001 · Cited by 57
Efficient neural network architecture for topology identification in smart grid
Zhao, Y., Chen, J., & Poor, H. V. (2016) · 2016 IEEE Global Conference on Signal and Information Processing (GlobalSIP) · doi:10.1109/globalsip.2016.7905955 · Cited by 12
Metadata
- Authors
- Zhu, H., & Giannakis, G. B.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2012-11
- Volume
- 27
- Issue
- 4
- Pages
- 2215-2224
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2057061105
- Cited by
- 203
- References
- 0
- FWCI
- 11.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sparse Overcomplete Representations for Efficient Identification of Power Line Outages. https://app.cochat.ai/papers/10.1109/tpwrs.2012.2192142
- The paper
- Zhu, H., & Giannakis, G. B. (2012). Sparse Overcomplete Representations for Efficient Identification of Power Line Outages. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2012.2192142
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.