Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 244

The DOI matches its Crossref record.

Determining Optimal Location and Size of Distributed Generation Resources Considering Harmonic and Protection Coordination Limits

Pandi, V. Ravikumar, Zeineldin, H. H., Xiao, Weidong · 2013 · IEEE Transactions on Power Systems

Abstract

In this paper, a new optimization problem is proposed to determine the maximum distributed generation (DG) penetration level by optimally selecting types, locations and sizes of utility owned DG units. The DG penetration level could be limited by harmonic distortion because of the nonlinear current injected by inverter-based DG units and also protection coordination constraints because of the variation in fault current caused by synchronous-based DG units. Hence the objective of the proposed problem is to maximize DG penetration level from both types of DG units, taking into account power balance constraints, bus voltage limits, total and individual harmonic distortion limits specified by the IEEE-519 standard, over-current relay operating time limits, and protection coordination constraints. The DG penetration study is formulated as a nonlinear programming (NLP) problem and tested on the IEEE-30 bus looped distribution network with ten load and DG scenarios. Similarly, feasibility assessment of customer owned DG unit installations considering power quality and protection coordination is also studied. Simulation results show the effectiveness of the proposed approach, which can serve as an efficient planning tool for utility operators.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tpwrs.2012.2209687

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 244

Metadata

Authors
Pandi, V. R., Zeineldin, H. H., & Xiao, W.
Venue
IEEE Transactions on Power Systems
Published
2013-05
Volume
28
Issue
2
Pages
1245-1254
ISSN
  • 0885-8950 (ISSN-L)
  • 1558-0679
OpenAlex
W2118756241
Cited by
244
References
0
FWCI
9.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determining Optimal Location and Size of Distributed Generation Resources Considering Harmonic and Protection Coordination Limits. https://app.cochat.ai/papers/10.1109/tpwrs.2012.2209687
The paper
Pandi, V. R., Zeineldin, H. H., & Xiao, W. (2013). Determining Optimal Location and Size of Distributed Generation Resources Considering Harmonic and Protection Coordination Limits. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2012.2209687

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.