The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Protection challenges under bulk penetration of renewable energy resources in power systems: A review
Open accessAbstract
Among different sources of alternate energy, wind and solar are two prominent and promising alternatives to meet the future electricity needs for mankind. Generally, these sources are integrated at the distribution utilities to supply the local distribution customers. If the power generated by these sources is bulk, then they are either integrated at the distribution/transmission level or may be operated in an island mode if feasible. The integration of these renewables in the power network will change the fault level and network topologies. These fault levels are intermittent in nature and existing protection schemes may fail to operate because of their pre-set condition. Therefore, the design and selection of a proper protection scheme is very much essential for reliable control and operation of renewable integrated power systems. Depending upon the level of infeed and location of the renewable integration, the protection requirements are different. For low renewable infeed at the distribution level, the existing relay settings are immune from any small change in the network fault current from new incoming renewables. However, bulk renewable infeed requires modification in the existing protection schemes to accommodate the fault current variation from the incoming renewables. For bulk penetration of the renewable, the requirement of modified/additional protection schemes is unavoidable. Adaptive relaying and non-adaptive relaying schemes are discussed in the literature for protection of power networks, which are experiencing dynamic fault currents and frequent changing network topologies. This article presents a detailed review of protection schemes for renewable integrated power networks which includes distribution, transmission and microgrid systems. The merits and demerits of these protection schemes are also identified in this article for the added interest of the readers. The visible scope of advance protection schemes which may be suitable for providing reliable protection for dynamic fault current networks is also explored.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ridethrough of Wind Turbines with Doubly-Fed Induction Generator During a Voltage Dip
Morren, J., & deHaan, S. W. H. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.845526 · Cited by 873
Brahma, S. M., & Girgis, A. A. (2004) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2003.820204 · Cited by 679
Optimal Protection Coordination for Microgrids With Grid-Connected and Islanded Capability
Najy, W., Zeineldin, H. H., & Woon, W. L. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2192893 · Cited by 428
Technical challenges associated with the integration of wind power into power systems
Georgilakis, P. S. (2006) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2006.10.007 · Cited by 405
A Non-unit Protection Scheme for DC Microgrid Based on Local Measurements
Meghwani, A., Srivastava, S. C., & Chakrabarti, S. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2555844 · Cited by 351
An Adaptive Overcurrent Protection Scheme for Distribution Networks
Coffele, F., Booth, C., & Dysko, A. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2013.2294879 · Cited by 338
A Protection Strategy and Microprocessor-Based Relay for Low-Voltage Microgrids
Zamani, M. A., Sidhu, T. S., & Yazdani, A. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2120628 · Cited by 324
El-Khattam, W., & Sidhu, T. S. (2008) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2008.915778 · Cited by 283
Casagrande, E., Woon, W. L., Zeineldin, H. H., & Svetinovic, D. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2251017 · Cited by 276
Wan, H., Li, K. K., & Wong, K. P. (2010) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2059492 · Cited by 250
Cited by
Sinsel, S. R., Riemke, R. L., & Hoffmann, V. H. (2020) · Renewable Energy · doi:10.1016/j.renene.2019.06.147 · Cited by 964
A critical review of the integration of renewable energy sources with various technologies
Erdiwansyah, Mahidin, Husin, H., Nasaruddin, Zaki, M., & Muhibbuddin (2021) · Protection and Control of Modern Power Systems · doi:10.1186/s41601-021-00181-3 · Cited by 473
Detection of microgrid cyberattacks using network and system management
Karanfil, M., Rebbah, D. E., Debbabi, M., Kassouf, M., Ghafouri, M., Youssef, E.-N. S., & Hanna, A. (2023) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2022.3218934 · Cited by 51
Meera, P. S., & Hemamalini, S. (2022) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2022.102812 · Cited by 43
Ilyushin, P., Volnyi, V., Suslov, K., & Filippov, S. (2022) · Energies · doi:10.3390/en15239186 · Cited by 30
Metadata
- Authors
- Central Power Research Institute, Telukunta, V., Pradhan, J., Central Power Research Institute, Agrawal, A., Central Power Research Institute, Singh, M., Central Power Research Institute, Srivani, S. G., & R V College of Engineering
- Venue
- CSEE Journal of Power and Energy Systems
- Publisher
- Power System Technology Press
- Published
- 2017-12-25
- Volume
- 3
- Issue
- 4
- Pages
- 365-379
- ISSN
- 2096-0042 (ISSN-L)
- OpenAlex
- W2883919122
- Cited by
- 544
- References
- 25
- FWCI
- 23.42
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Protection challenges under bulk penetration of renewable energy resources in power systems: A review. https://app.cochat.ai/papers/10.17775/cseejpes.2017.00030
- The paper
- Central Power Research Institute, Telukunta, V., Pradhan, J., Central Power Research Institute, Agrawal, A., Central Power Research Institute, Singh, M., Central Power Research Institute, Srivani, S. G., & R V College of Engineering. (2017). Protection challenges under bulk penetration of renewable energy resources in power systems: A review. CSEE Journal of Power and Energy Systems. https://doi.org/10.17775/cseejpes.2017.00030
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.