A Three-Phase Power Flow Approach for Integrated 3-Wire MV and 4-Wire Multigrounded LV Networks with Rooftop Solar PV

Alam, M. J. E., Muttaqi, K. M., Sutanto, D.·2013·IEEE Transactions on Power Systems

Abstract

With increasing level of rooftop solar photovoltaic (PV) penetration into low voltage (LV) distribution networks, analysis with realistic network models is necessary for adequate capturing of network behavior. Traditional three-phase 3-wire power flow approach lacks the capability of exact analysis of 4-wire multigrounded LV networks due to the approximation of merging the neutral wire admittance into the phase wire admittances. Such an approximation may not be desirable when neutral wire and grounding effects need to be assessed, especially in the presence of single-phase solar power injection that may cause a significant level of network unbalance. This paper proposes a three-phase power flow approach for distribution networks while preserving the original 3-wire and 4-wire configurations for more accurate estimation of rooftop PV impacts on different phases and neutrals. A three-phase transformer model is developed to interface between the 3-wire medium voltage (MV) and the 4-wire LV networks. Also an integrated network model is developed for an explicit representation of different phases, neutral wires and groundings of a distribution system. A series of power flow calculations have been performed using the proposed approach to investigate the impacts of single-phase variable PV generation on an Australian distribution system and results are presented.

Integrity signals

Registry

Crossref · 10.1109/tpwrs.2012.2222940

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The study in [31] considered grounding resistances of approximately 5 Ω and used a 0.5 V N-G voltage limit as the common-mode threshold for sensitive equipment [32], showing that unbalanced PV connection patterns can drive N-G voltages above this level.

    “The study considered grounding resistances of approximately 5 Ω and used a 0.5 V N-G voltage limit as the common-mode threshold for sensitive equipment [32], showing that unbalanced PV connection patterns can drive N-G voltages above this level.”
  • Other work has investigated integrated three-wire/four-wire approaches for multi-grounded LV networks and highlighted how neutral grounding resistance and unbalanced loading can drive N-G voltages above common mode limits for sensitive equipment.

    “Other work has investigated integrated three-wire/four-wire approaches for multi-grounded LV networks and highlighted how neutral grounding resistance and unbalanced loading can drive N-G voltages above common mode limits for sensitive equipment [31,32].”
  • An integrated three-wire/four-wire modelling approach for assessing N-G voltages in multi-grounded LV networks was proposed in reference [31], where the influence of LV neutral behaviour on the upstream network was also examined.

    “An integrated three-wire/four-wire modelling approach for assessing N-G voltages in multi-grounded LV networks was proposed in reference [31], where the influence of LV neutral behaviour on the upstream network was also examined.”

Cited by

Sorted by citations

Authors
Alam, M. J. E., Muttaqi, K. M., & Sutanto, D.
Affiliations
University of Wollongong (AU)
Venue
IEEE Transactions on Power Systems
Published
2013-05
Volume
28
Issue
2
Pages
1728-1737
ISSN
  • 0885-8950 (ISSN-L)
  • 1558-0679
OpenAlex
W1964960728
Cited by
114
References
0
Citations by year
2026: 4 · 2025: 3 · 2024: 5 · 2023: 3 · 2022: 5 · 2021: 14 · 2020: 19 · 2019: 14 · 2018: 5 · 2017: 12 · 2016: 11 · 2015: 6 · 2014: 8 · 2013: 5
FWCI
3.88
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Power Systems (publishedVersion)
  • Research Online (University of Wollongong) (submittedVersion)
  • Figshare (submittedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power System Optimization and Stability
Keywords
three-phase power flow, rooftop solar, distribution network modeling, medium-voltage distribution networks

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review