Electromechanical Transient Modeling of Modular Multilevel Converter Based Multi-Terminal HVDC Systems
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This paper studies the techniques for modeling modular multilevel converter (MMC) based multi-terminal HVDC (MTDC) systems in the electromechanical transient mode. Firstly, the mathematical model of the MMC and its corresponding equivalent circuit are established, which are similar to those of the two level converters. Then, a power flow calculation method for AC/DC systems containing MMC-MTDC systems is developed. Two dynamic models for MMC-MTDC systems are developed in the paper. One is the detailed model, taking into account of the AC side circuit, the inner controllers, the modulation strategies, the outer controllers and the MTDC circuit. The other is the simplified model, which only reserves the outer controllers and partial dynamics of the MTDC circuit based on a quantitative analysis of the detailed model's dynamic processes, and it can be used in electromechanical transient simulation with a larger step size. Both the detailed and the simplified models are implemented on PSS/E and compared with the accurate electromagnetic transient models on PSCAD in a four terminal MMC-MTDC system; the result proves the validity of the developed models. Lastly, a stability study of a modified New England 39-bus system is executed, and the result shows that the AC fault can be isolated well in an MMC-MTDC asynchronously connected AC grid.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387
Self-citationGnanarathna, U. N., Gole, A. M., & Jayasinghe, R. P. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2060737 · Cited by 739
Guan, M., & Xu, Z. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2192752 · Cited by 549
Self-citation
Cited by
Dekka, A., Wu, B., Fuentes, R. L., Perez, M., & Zargari, N. R. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2742938 · Cited by 576
Bergna-Diaz, G., Freytes, J., Guillaud, X., D'Arco, S., & Suul, J. A. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2793159 · Cited by 100
Arm Current Control Strategy for MMC-HVDC Under Unbalanced Conditions
Liang, Y., Liu, J., Zhang, T., & Yang, Q. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2554620 · Cited by 81
Metadata
- Authors
- Liu, S., Xu, Z., Hua, W., Tang, G., & Xue, Y.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2014-01
- Volume
- 29
- Issue
- 1
- Pages
- 72-83
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2175123584
- Cited by
- 167
- References
- 3
- FWCI
- 8.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electromechanical Transient Modeling of Modular Multilevel Converter Based Multi-Terminal HVDC Systems. https://app.cochat.ai/papers/10.1109/tpwrs.2013.2278402
- The paper
- Liu, S., Xu, Z., Hua, W., Tang, G., & Xue, Y. (2014). Electromechanical Transient Modeling of Modular Multilevel Converter Based Multi-Terminal HVDC Systems. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2013.2278402
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.