Unbalanced Power Flow in Distribution Systems With Embedded Transformers Using the Complex Theory in <formula formulatype="inline"> <tex Notation="TeX">$\alpha \beta 0\;$</tex></formula> Stationary Reference Frame
Open accessAbstract
This paper presents three new contributions to power flow analysis of unbalanced three-phase distribution systems. First, a complex vector based model in$\alpha \beta 0\;$stationary reference frame is developed to state the power flow equations using a compact matrix formulation. The proposed model is based on Kirchhoff's current law (KCL) and Kirchhoff's voltage law (KVL). Then, a general and exact power transformer model in the$\alpha \beta 0\;$reference frame is proposed. Finally, this transformer model is incorporated into the power flow problem. It will be shown that the use of an orthogonal reference frame simplifies the modeling of the distribution network components. In this work, both the network and the power transformer, as well as PQ type loads, PQ and PV type generators and a slack bus are modeled. By using the node incidence matrix instead of the admittance matrix, the information about the grid topology and the grid parameters (including power transformers) is separately organized. As it will be demonstrated, the proposed formulation is ready to incorporate other complex models of loads, generators or storage devices. The model is tested by using the IEEE 4-Node and the IEEE 123-Node Test Feeders with different transformer connections and balanced and unbalanced lines and loads.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“As such, conventional power flow techniques, such as Gauss-Seidel and Newton Raphson, become slow or may even diverge [27], [28].”
From Optimal placement of electric vehicle charging stations in the active distribution network (2020) · cites this paper as [27]
In the citing paper
“The distribution system is usually a radial or weak meshed network having high R/X ratio [27].”
From Optimal placement of electric vehicle charging stations in the active distribution network (2020) · cites this paper as [27]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 31
- 10.1109/TPWRS.2009.2030396 · DOI
- 10.1109/T-AIEE.1951.5060553 · DOI
- 10.1109/TPWRD.2003.813818 · DOI
- 10.1109/TPWRS.2005.846056 · DOI
- 10.1109/TPWRS.2011.2175754 · DOI
- 10.1109/TVT.2012.2196298 · DOI
- 10.1109/TPWRS.2003.818597 · DOI · Paper page
- 10.1109/TPWRS.2003.821624 · DOI
- 10.1109/TPAS.1968.292199 · DOI
- 10.1109/61.97706 · DOI
- 10.1109/TPWRS.2003.814905 · DOI
- baran, 1997, Distribution transformer models for branch current based feeder analysis, IEEE Trans Power Syst, 12, 698, 10.1109/59.589655 · DOI
- 0, Distribution test feeders
- 10.1109/TPWRD.2011.2172640 · DOI
- 10.1137/0720042 · DOI
- 10.1109/TPWRD.2010.2042825 · DOI
- 10.1109/TIE.2012.2196889 · DOI
- 10.1201/9781420041736 · DOI · Paper page
- 10.1109/28.968195 · DOI
- 10.1109/TIE.2012.2185914 · DOI
- 10.1109/TIE.2012.2194951 · DOI
- 10.1109/PES.2011.6039172 · DOI
- 10.1016/j.epsr.2011.10.005 · DOI
- 10.1109/PES.2003.1267146 · DOI
- 10.1109/TPWRS.2004.835659 · DOI
- 10.1109/TPWRS.2011.2175256 · DOI
- 10.1109/TPWRS.2005.857847 · DOI
- 10.1109/TPWRS.2008.920184 · DOI
- 10.1109/TPWRS.2005.851933 · DOI
- milano, 2010, Power System Modelling and Scripting, 10.1007/978-3-642-13669-6 · DOI
- 10.1109/28.740861 · DOI
Cited by
Sorted by citations
Optimal placement of electric vehicle charging stations in the active distribution network
Zeb, M. Z., Imran, K., Khattak, A., Janjua, A. K., Pal, A., Nadeem, M., Zhang, J., & Khan, S. (2020) · IEEE Access · doi:10.1109/access.2020.2984127 · Cited by 263
Petridis, S., Blanas, O., Rakopoulos, D., Stergiopoulos, F., Nikolopoulos, N., & Voutetakis, S. (2021) · Energies · doi:10.3390/en14040897 · Cited by 38
Metadata
- Authors
- Arboleya, P., Gonzalez-Moran, C., & Coto, M.
- Affiliations
- Universidad de Oviedo (ES)
- Venue
- IEEE Transactions on Power Systems
- Published
- 2014-05
- Volume
- 29
- Issue
- 3
- Pages
- 1012-1022
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W1969351199
- Cited by
- 49
- References
- 0
- Citations by year
- 2026: 3 · 2025: 2 · 2024: 2 · 2023: 4 · 2022: 7 · 2021: 3 · 2020: 2 · 2019: 7 · 2018: 4 · 2017: 7 · 2016: 4 · 2015: 3 · 2014: 1
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Locations
- IEEE Transactions on Power Systems (publishedVersion)
- Consultation of the Doctoral Thesis Database (TESEO) (Ministerio de Educación, Cultura y Deporte) (submittedVersion, cc-by-nc-nd)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power System Optimization and Stability
- Keywords
- unbalanced power flow, distribution systems, Kirchhoff's laws, IEEE 123-node test feeder, transformer connections
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Unbalanced Power Flow in Distribution Systems With Embedded Transformers Using the Complex Theory in <formula formulatype="inline"> <tex Notation="TeX">$\alpha \beta 0\;$</tex></formula> Stationary Reference Frame. https://app.cochat.ai/papers/10.1109/tpwrs.2013.2292112
- The paper
- Arboleya, P., Gonzalez-Moran, C., & Coto, M. (2014). Unbalanced Power Flow in Distribution Systems With Embedded Transformers Using the Complex Theory in <formula formulatype="inline"> <tex Notation="TeX">$\alpha \beta 0\;$</tex></formula> Stationary Reference Frame. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2013.2292112