The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Security-Constrained Unit Commitment With Linearized System Frequency Limit Constraints
Abstract
Rapidly increasing the penetration level of renewable energies has imposed new challenges to the operation of power systems. Inability or inadequacy of these resources in providing inertial and primary frequency responses is one of the important challenges. In this paper, this issue is addressed within the framework of security-constrained unit commitment (SCUC) by adding new constraints representing the system frequency response. A modified system frequency response model is first derived and used to find analytical representation of system minimum frequency in thermal-dominant multi-machine systems. Then, an effective piecewise linearization (PWL) technique is employed to linearize the nonlinear function representing the minimum system frequency, facilitating its integration in the SCUC problem. The problem is formulated as a mixed-integer linear programming (MILP) problem which is solved efficiently by available commercial solvers. The results indicate that the proposed method can be utilized to integrate renewable resources into power systems without violating system frequency limits.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Power System Stability and Control
(2007) · CRC Press eBooks · doi:10.1201/9781420009248 · Cited by 1,828
A Computationally Efficient Mixed-Integer Linear Formulation for the Thermal Unit Commitment Problem
Carrion, M., & Arroyo, J. M. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.876672 · Cited by 1,731
Model Building in Mathematical Programming
Maher, M. J., & Williams, H. P. (1979) · Journal of the Operational Research Society · doi:10.2307/3009304 · Cited by 1,245
Security-Constrained Unit Commitment With Volatile Wind Power Generation
Wang, J., Shahidehpour, M., & Li, Z. (2008) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2008.926719 · Cited by 914
Delille, G., Francois, B., & Malarange, G. (2012) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2012.2205025 · Cited by 776
Stochastic Security for Operations Planning With Significant Wind Power Generation
Bouffard, F., & Galiana, F. D. (2008) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2008.919318 · Cited by 713
Unit Commitment for Systems With Significant Wind Penetration
Tuohy, A., Meibom, P., Denny, E., & O'Malley, M. (2009) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2016470 · Cited by 703
Ortega-Vazquez, M. A., & Kirschen, D. S. (2009) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2008.2004745 · Cited by 665
Economic Valuation of Reserves in Power Systems With High Penetration of Wind Power
Morales, J. M., Conejo, A. J., & Perez-Ruiz, J. (2009) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2016598 · Cited by 573
Cited by
Primary Frequency Response in Capacity Expansion with Energy Storage
Carrion, M., Dvorkin, Y., & Pandzic, H. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2735807 · Cited by 70
Metadata
- Authors
- Ahmadi, H., & Ghasemi, H.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2014-07
- Volume
- 29
- Issue
- 4
- Pages
- 1536-1545
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2001860597
- Cited by
- 386
- References
- 19
- FWCI
- 6.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Security-Constrained Unit Commitment With Linearized System Frequency Limit Constraints. https://app.cochat.ai/papers/10.1109/tpwrs.2014.2297997
- The paper
- Ahmadi, H., & Ghasemi, H. (2014). Security-Constrained Unit Commitment With Linearized System Frequency Limit Constraints. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2014.2297997
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.