The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Governor Rate-Constrained OPF for Primary Frequency Control Adequacy
Abstract
The integration of non-dispatchable generation has led to a change in the dynamics of primary frequency response. This change, mostly driven by the limited contribution of non-dispatchable generation to both total system inertia and governor response, may deteriorate the performance of current practices for determining primary reserves to the extend that real time operation reliability may no longer be ensured. This work establishes sufficient conditions for ensuring primary response adequacy through ex-ante dispatch instructions. A simplified dynamic model of primary frequency response (including system inertia, system governors' ramp rates, and dead bands) is developed to formulate a constraint suitable for an OPF framework. A simulation of ERCOT is presented to test the proposed formulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Stoft, S. (2002) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470545584 · Cited by 1,160
A Survey of Frequency and Voltage Control Ancillary Services—Part I: Technical Features
Rebours, Y. G., Kirschen, D. S., Trotignon, M., & Rossignol, S. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.888963 · Cited by 788
The Inertial Response of Induction-Machine-Based Wind Turbines
Mullane, A., & O'Malley, M. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.852081 · Cited by 309
Frequency Control in Competitive Electricity Market Dispatch
Doherty, R., Lalor, G., & O'Malley, M. J. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.852146 · Cited by 141
Wind and Energy Markets: A Case Study of Texas
Baldick, R. (2011) · IEEE Systems Journal · doi:10.1109/jsyst.2011.2162798 · Cited by 98
Self-citation
Cited by
Primary Frequency Response in Capacity Expansion with Energy Storage
Carrion, M., Dvorkin, Y., & Pandzic, H. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2735807 · Cited by 70
Metadata
- Authors
- Chavez, H., Baldick, R., & Sharma, S.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2014-05
- Volume
- 29
- Issue
- 3
- Pages
- 1473-1480
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2024602078
- Cited by
- 254
- References
- 6
- FWCI
- 4.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Governor Rate-Constrained OPF for Primary Frequency Control Adequacy. https://app.cochat.ai/papers/10.1109/tpwrs.2014.2298838
- The paper
- Chavez, H., Baldick, R., & Sharma, S. (2014). Governor Rate-Constrained OPF for Primary Frequency Control Adequacy. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2014.2298838
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.