The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Value of Distribution Network Reconfiguration in Presence of Renewable Energy Resources
Abstract
Proliferation of renewable energy resources in distribution networks has captured distribution companies' attention towards more active management tools. Thanks to the smart grid paradigm, hourly network reconfiguration, which is still among immature ideas, can bring the activeness required to handle fluctuating output of renewable resources. The aim of this study is to analyze the worthiness of the hourly reconfiguration in the presence of renewable energy resources. For doing so, a mathematical model is devised to minimize daily network losses via applying hourly reconfigurations. The model is a mixed integer second-order cone programming problem and is solved via MOSEK solver. The electrical demand variations as well as renewable power generation fluctuations during a day are taken into account. The proposed method is applied to the Baran 33-bus system and the results including a great deal of sensitivity analyses on key parameters are presented and discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Network reconfiguration in distribution systems for loss reduction and load balancing
Baran, M. E., & Wu, F. F. (1989) · IEEE Transactions on Power Delivery · doi:10.1109/61.25627 · Cited by 5,077
Network Reconfiguration in Distribution Systems for Loss Reduction and Load Balancing
Baran, M. E., & Wu, F. F. (1989) · IEEE Power Engineering Review · doi:10.1109/mper.1989.4310642 · Cited by 3,350
Branch Flow Model: Relaxations and Convexification—Part I
Farivar, M., & Low, S. H. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2255317 · Cited by 1,541 · cited 3×
“On the other hand, the branch flow model focuses on currents and powers flowing through the branches [31].”
BackgroundRao, R. S., Ravindra, K., Satish, K., & Narasimham, S. V. L. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2197227 · Cited by 1,023
Minimum Loss Network Reconfiguration Using Mixed-Integer Convex Programming
Jabr, R. A., Singh, R. N., & Pal, B. C. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2011.2180406 · Cited by 632
Fabbri, A., GomezSanRoman, T., RivierAbbad, J., & MendezQuezada, V. H. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.852148 · Cited by 458
Convex Models of Distribution System Reconfiguration
Taylor, J. A., & Hover, F. S. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2184307 · Cited by 444
Effect of Load Models in Distributed Generation Planning
Singh, D., Misra, R. K., & Singh, D. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.907582 · Cited by 434
Jeon, Y.-J., Kim, J.-C., Kim, J.-O., Shin, J.-R., & Lee, K. Y. (2002) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2002.803823 · Cited by 287
Branch Flow Model: Relaxations and Convexification—Part II
Farivar, M., & Low, S. H. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2255318 · Cited by 287
Khushalani, S., Solanki, J. M., & Schulz, N. N. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.901476 · Cited by 219
Malekpour, A. R., Niknam, T., Pahwa, A., & Kavousi‐Fard, A. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2218261 · Cited by 182
Wang, C., & Cheng, H. Z. (2008) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.913293 · Cited by 178
Raju, G., & Bijwe, P. R. (2008) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2008.926084 · Cited by 167
Optimization of Distribution Network Incorporating Distributed Generators: An Integrated Approach
Tan, S., Xu, J.-X., & Panda, S. K. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2253564 · Cited by 161
A Comprehensive Centralized Approach for Voltage Constraints Management in Active Distribution Grid
Capitanescu, F., Bilibin, I., & Romero-Ramos, E. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2287897 · Cited by 158
de Oliveira, L. W., Carneiro, S., de Oliveira, E. J., Pereira, J. L. R., da Silva, I. C., & Costa, J. S. (2010) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2010.01.030 · Cited by 155
Minimum loss operation of distribution networks with photovoltaic generation
Jabr, R. (2014) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2012.0213 · Cited by 75
Ding, F., & Loparo, K. A. (2014) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2337280 · Cited by 35
Cited by
Distribution Locational Marginal Pricing (DLMP) for Congestion Management and Voltage Support
Bai, L., Wang, J., Wang, C., Chen, C., & Li, F. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2767632 · Cited by 446
Lei, S., Chen, C., Li, Y., & Hou, Y. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2899353 · Cited by 427
Transportable Energy Storage for More Resilient Distribution Systems With Multiple Microgrids
Yao, S., Wang, P., & Zhao, T. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2824820 · Cited by 354
Rolling Optimization of Mobile Energy Storage Fleets for Resilient Service Restoration
Yao, S., Wang, P., Liu, X., Zhang, H., & Zhao, T. (2020) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2930012 · Cited by 292
Yan, M., Shahidehpour, M., Paaso, A., Zhang, L., Alabdulwahab, A., & Abusorrah, A. (2021) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2020.3032889 · Cited by 275
Metadata
- Authors
- Dorostkar-Ghamsari, M. R., Fotuhi-Firuzabad, M., Lehtonen, M., & Safdarian, A.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2016-05
- Volume
- 31
- Issue
- 3
- Pages
- 1879-1888
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2337668381
- Cited by
- 298
- References
- 19
- FWCI
- 7.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.