Voltage Control in PV-Rich LV Networks Without Remote Monitoring
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The adoption of on-load tap changer (OLTC)-fitted transformers in low-voltage (LV) networks can be a potential solution to counteract voltage rise caused by high penetrations of residential photovoltaic (PV) systems. However, to control voltages in an efficient and flexible way, observability of remote points is required. This study proposes a generic and practical remote voltage estimation method for the end points of LV feeders to substitute the need of remote monitoring without compromising performance and, hence, avoid the corresponding investment. This scheme identifies first the number of customers per phase to then produce a generic feeder. The latter is used to estimate remote voltages based on substation measurements. The performance of the proposed estimation is compared against the case with monitoring considering a rule-based OLTC control logic as well as different control cycles on a real UK residential LV network. To cater for the load and generation uncertainties a time-series Monte Carlo analysis is applied. Furthermore, different uneven PV penetrations per feeder are considered. Results show that the use of estimated voltages can be as effective as those from remote monitoring. Consequently, the proposed approach can help making the adoption of OLTC-fitted transformers in future LV networks more cost effective.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Distribution System Modeling and Analysis
Kersting, W. (2012) · Electric Power Engineering Series · doi:10.1201/b12056-31 · Cited by 1,241
Distribution System Modeling and Analysis
Kersting, W. H. (2001) · doi:10.1201/9781420041736 · Cited by 354
Cited by
A Comprehensive Assessment of PV Hosting Capacity on Low-Voltage Distribution Systems
Torquato, R., Salles, D., Oriente Pereira, C., Meira, P. C. M., & Freitas, W. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2018.2798707 · Cited by 270
Methods and strategies for overvoltage prevention in low voltage distribution systems with PV
Hashemi, S., & Østergaard, J. (2017) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2016.0277 · Cited by 212
Review on the PV Hosting Capacity in Distribution Networks
Fatima, S., Püvi, V., & Lehtonen, M. (2020) · Energies · doi:10.3390/en13184756 · Cited by 137
“The authors of ([28,30,37,60,65,83,88–90]) and ([23,75,76]) considered EN-50160(±10% Un) and BS EN-50160 (−6/+10%Un) standard for voltage limits, respectively.”
BackgroundUmoh, V., Davidson, I., Adebiyi, A., & Ekpe, U. (2023) · Energies · doi:10.3390/en16083609 · Cited by 71
OPF-Based CVR Operation in PV-Rich MV-LV Distribution Networks
Gutierrez-Lagos, L., & Ochoa, L. F. (2019) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2894795 · Cited by 67
Self-citation
Metadata
- Authors
- Procopiou, A. T., & Ochoa, L. F.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2017-03
- Volume
- 32
- Issue
- 2
- Pages
- 1224-1236
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2497340882
- Cited by
- 86
- References
- 2
- FWCI
- 4.42
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Voltage Control in PV-Rich LV Networks Without Remote Monitoring. https://app.cochat.ai/papers/10.1109/tpwrs.2016.2591063
- The paper
- Procopiou, A. T., & Ochoa, L. F. (2017). Voltage Control in PV-Rich LV Networks Without Remote Monitoring. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2016.2591063
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.