Decentralized Optimization of Multi-Area Electricity-Natural Gas Flows Based on Cone Reformulation
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
A large-scale integrated energy system can represent several subsystems representing areas that are tied by electricity and natural gas networks. Accordingly, we propose a decentralized optimal energy flow (DOEF) calculation as compared with a centralized solution method. The proposed approach demonstrates the merits of the decentralized operation and control of a multi-area integrated electricity-natural gas system (IEGS), in terms of large-scale modeling requirements, faster computations, and data management for local sensitivity analyses. Using the proposed decentralized structure, the communication burden is relatively light as individual area operators in a multi-area IEGS will make optimal dispatch decisions independently and the corresponding information is shared with adjacent subsystems. The reformulation of the second-order cone (SOC) is proposed using advanced sequential cone programming (SCP) to handle the nonlinear steady-state natural gas flow, which provides a feasible solution with a high degree of computational efficiency. Furthermore, an iterative alternating direction method of multipliers (I-ADMM) is adopted to manage the nonconvexity of integer variables, which guarantees a satisfactory convergence performance. Case studies on three multi-area IEGS validate the effectiveness of the proposed model in a multi-area IEGS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boyd, S., Parikh, N., Chu, E., Peleato, B., & Eckstein, J. (2011) · Foundations and Trends® in Machine Learning · doi:10.1561/2200000016 · Cited by 17,075
Boyd, S. (2010) · now publishers, Inc. eBooks · doi:10.1561/9781601984616 · Cited by 12,677
Use, E. (1990) · Medical Entomology and Zoology · Cited by 1,184
Variations and extension of the convex–concave procedure
Lipp, T., & Boyd, S. (2016) · Optimization and Engineering · doi:10.1007/s11081-015-9294-x · Cited by 744
Networked Microgrids for Enhancing the Power System Resilience
Li, Z., Shahidehpour, M., Aminifar, F., Alabdulwahab, A., & Al-Turki, Y. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2685558 · Cited by 640 · cited 1×
“The interconnection advantages of a multi-area energy system lie on system reliability enhancement by reserve sharing and economic operation via resource integration [13].”
BackgroundSelf-citationDecomposition techniques in mathematical programming: engineering and science applications
(2006) · Choice Reviews Online · doi:10.5860/choice.44-2155 · Cited by 467 · cited 1×
“Lagrangian relaxation (LR) is the fundamental method that constructs a dual function by relaxing coupling constraints and variables, which is further decomposed into several subproblems [17].”
MethodRobust Co-Optimization Scheduling of Electricity and Natural Gas Systems via ADMM
He, C., Wu, L., Liu, T., & Shahidehpour, M. (2016) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2016.2615104 · Cited by 424 · cited 5×
“Several decomposition methods are applied to an IEGS for achieving the synergistic operations of electric and natural gas networks [8], [12].”
MethodInfluentialSelf-citationImpact of Natural Gas Infrastructure on Electric Power Systems
Shahidehpour, M., Fu, Y., & Wiedman, T. (2005) · Proceedings of the IEEE · doi:10.1109/jproc.2005.847253 · Cited by 407 · cited 2×
“The interdependent operation of an IEGS affected by physical characteristics and capabilities of natural gas network and electric power system is introduced in [4].”
BackgroundSelf-citationA Fully Distributed Reactive Power Optimization and Control Method for Active Distribution Networks
Zheng, W., Wu, W., Zhang, B., Sun, H., & Liu, Y. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2396493 · Cited by 371 · cited 1×
“To improve the convergent speed, augmented Lagrangian decomposition (ALD) is proposed by introducing quadratic penalty terms into the traditional Lagrangian function [18].”
MethodLiu, C., Shahidehpour, M., & Wang, J. (2011) · Chaos: An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.3600761 · Cited by 235 · cited 1×
“Although the transient model with distributed parameters and time-varying state variables can precisely express natural gas flow, computation burden is dramatically increased [20].”
BackgroundSelf-citation
Cited by
Yan, M., Shahidehpour, M., Paaso, A., Zhang, L., Alabdulwahab, A., & Abusorrah, A. (2021) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2020.3032889 · Cited by 275
Self-citation
Metadata
- Authors
- He, Y., Yan, M., Shahidehpour, M., Li, Z., Guo, C., Wu, L., & Ding, Y.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2018-07
- Volume
- 33
- Issue
- 4
- Pages
- 4531-4542
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2776951995
- Cited by
- 203
- References
- 15
- FWCI
- 7.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.