Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 398

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Large Signal Synchronizing Instability of PLL-Based VSC Connected to Weak AC Grid

Hu, Qi, Fu, Lijun, Ma, Fan, Ji, Feng · 2019 · IEEE Transactions on Power Systems

Abstract

Similar large signal synchronizing instability that is common in traditional power system also exists in voltage source converter (VSC) dominated power system, which is increasingly reported and investigated. In this paper, the large signal instability of phase locked loop (PLL) synchronized VSC connected to weak ac grid is investigated. First, the influence of high grid impedance on PLL's dynamics is explored and an additional feedback loop is found to be introduced, which deteriorates the performance of PLL. Then an analysis model that is similar as the rotor motion model of synchronous generator (SG) is developed. Based on the developed model, equal-area method is employed to carry out the large-signal stability analysis. The large signal instability is found to be mainly resulted by the following two factors. One is the nonexistence of equilibrium point, which is similar as that there does not exist intersection between the mechanical power input curve and electromagnetic restoring force curve in SG grid connected system. The other is related with the transition process resulted by insufficient decelerating area, which leads to that the system cannot stably go through the transition from initial point to the existing equilibrium point. The proposed analysis not only contributes to revealing the physical mechanism but also provides guidance for the future improvement measures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tpwrs.2019.2892224

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 398

Metadata

Authors
Hu, Q., Fu, L., Ma, F., & Ji, F.
Venue
IEEE Transactions on Power Systems
Published
2019-07
Volume
34
Issue
4
Pages
3220-3229
ISSN
  • 0885-8950 (ISSN-L)
  • 1558-0679
OpenAlex
W2911026196
Cited by
398
References
14
FWCI
18.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Large Signal Synchronizing Instability of PLL-Based VSC Connected to Weak AC Grid. https://app.cochat.ai/papers/10.1109/tpwrs.2019.2892224
The paper
Hu, Q., Fu, L., Ma, F., & Ji, F. (2019). Large Signal Synchronizing Instability of PLL-Based VSC Connected to Weak AC Grid. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2019.2892224

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.