The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Large Signal Synchronizing Instability of PLL-Based VSC Connected to Weak AC Grid
Abstract
Similar large signal synchronizing instability that is common in traditional power system also exists in voltage source converter (VSC) dominated power system, which is increasingly reported and investigated. In this paper, the large signal instability of phase locked loop (PLL) synchronized VSC connected to weak ac grid is investigated. First, the influence of high grid impedance on PLL's dynamics is explored and an additional feedback loop is found to be introduced, which deteriorates the performance of PLL. Then an analysis model that is similar as the rotor motion model of synchronous generator (SG) is developed. Based on the developed model, equal-area method is employed to carry out the large-signal stability analysis. The large signal instability is found to be mainly resulted by the following two factors. One is the nonexistence of equilibrium point, which is similar as that there does not exist intersection between the mechanical power input curve and electromagnetic restoring force curve in SG grid connected system. The other is related with the transition process resulted by insufficient decelerating area, which leads to that the system cannot stably go through the transition from initial point to the existing equilibrium point. The proposed analysis not only contributes to revealing the physical mechanism but also provides guidance for the future improvement measures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Slotine, J.-J. E., & Li, W. (1991) · CERN Document Server (European Organization for Nuclear Research) · Cited by 18,975
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
Power electronics as efficient interface in dispersed power generation systems
Blaabjerg, F., Chen, Z., & Kjaer, S. B. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833453 · Cited by 2,588
VSC-Based HVDC Power Transmission Systems: An Overview
Flourentzou, N., Agelidis, V. G., & Demetriades, G. D. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2008441 · Cited by 2,216
A phase tracking system for three phase utility interface inverters
Chung, S.-K. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.844502 · Cited by 1,192
Impedance Modeling and Analysis of Grid-Connected Voltage-Source Converters
Cespedes, M., & Sun, J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2262473 · Cited by 1,167
Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters
Harnefors, L., Bongiorno, M., & Lundberg, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.904022 · Cited by 1,117
Zhou, J. Z., Ding, H., Fan, S., Zhang, Y., & Gole, A. M. (2014) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2330518 · Cited by 738
Dong, D., Wen, B., Boroyevich, D., Mattavelli, P., & Xue, Y. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2334665 · Cited by 709
Cited by
Grid-Synchronization Stability of Converter-Based Resources—An Overview
Wang, X., Taul, M. G., Wu, H., Liao, Y., Blaabjerg, F., & Harnefors, L. (2020) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2020.3020392 · Cited by 862
Revisiting Grid-Forming and Grid-Following Inverters: A Duality Theory
Li, Y., Gu, Y., & Green, T. C. (2022) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3151851 · Cited by 686
Design-Oriented Transient Stability Analysis of PLL-Synchronized Voltage-Source Converters
Wu, H., & Wang, X. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2937942 · Cited by 454
Fault Recovery Analysis of Grid-Forming Inverters With Priority-Based Current Limiters
Fan, B., & Wang, X. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3221209 · Cited by 131
Ravanji, M. H., Rathnayake, D. B., Mansour, M. Z., & Bahrani, B. (2023) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2023.3246566 · Cited by 47
Metadata
- Authors
- Hu, Q., Fu, L., Ma, F., & Ji, F.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2019-07
- Volume
- 34
- Issue
- 4
- Pages
- 3220-3229
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2911026196
- Cited by
- 398
- References
- 14
- FWCI
- 18.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Large Signal Synchronizing Instability of PLL-Based VSC Connected to Weak AC Grid. https://app.cochat.ai/papers/10.1109/tpwrs.2019.2892224
- The paper
- Hu, Q., Fu, L., Ma, F., & Ji, F. (2019). Large Signal Synchronizing Instability of PLL-Based VSC Connected to Weak AC Grid. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2019.2892224
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.