The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Active filtering of physiological motion in robotized surgery using predictive control
Abstract
This work presents a predictive-control approach to active mechanical filtering of complex, periodic motions of organs induced by respiration or heart beating in robotized surgery. Two different predictive-control schemes are proposed for the compensation of respiratory motions or cardiac motions. For respiratory motions, the periodic property of the disturbance has been included into the input-output model of the controlled system so as to have the robotic system learn and anticipate perturbation motions. A new cost function is proposed for the unconstrained generalized predictive controller (GPC), where reference tracking is decoupled from the rejection of predictable periodic motions. Cardiac motions are more complex, since they are the combination of two periodic nonharmonic components. An adaptive disturbance predictor is proposed which outputs future predicted disturbance values. These predicted values are used to anticipate the disturbance by using the predictive feature of a regular GPC. Experimental results are presented on a laboratory testbed and in vivo on pigs. They demonstrate the effectiveness of the two proposed methods to compensate complex physiological motion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adaptive cancelling of physiological tremor for improved precision in microsurgery
Riviere, C. N., Rader, R. S., & Thakor, N. V. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686791 · Cited by 260 · cited 2×
“The same adaptive algorithm is used in [ 6 ] and [7] to model physiological tremor of the surgeon’s hand.”
MethodToward active tremor canceling in handheld microsurgical instruments
Riviere, C. N., Ang, W. T., & Khosla, P. K. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817506 · Cited by 245
An adaptive estimation of periodic signals using a Fourier linear combiner
Vaz, C., Kong, X., & Thakor, N. (1994) · IEEE Transactions on Signal Processing · doi:10.1109/78.258116 · Cited by 108 · cited 1×
“A similar approach is described in [23].”
Cited by
Kassahun, Y., Yu, B., Tibebu, A. T., Stoyanov, D., Giannarou, S., Metzen, J. H., & Vander Poorten, E. (2016) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-015-1305-z · Cited by 238
Chaumette, F. (2007) · Modeling, Performance Analysis and Control of Robot Manipulators · doi:10.1002/9780470612286.ch6 · Cited by 5
Metadata
- Authors
- Ginhoux, R., Gangloff, J., de Mathelin, M., Soler, L., Sanchez, M. M. A., & Marescaux, J.
- Venue
- IEEE Transactions on Robotics
- Published
- 2005-02
- Volume
- 21
- Issue
- 1
- Pages
- 67-79
- ISSN
- 1552-3098 (ISSN-L)
- OpenAlex
- W2121677103
- Cited by
- 247
- References
- 3
- FWCI
- 41.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Active filtering of physiological motion in robotized surgery using predictive control. https://app.cochat.ai/papers/10.1109/tro.2004.833812
- The paper
- Ginhoux, R., Gangloff, J., de Mathelin, M., Soler, L., Sanchez, M. M. A., & Marescaux, J. (2005). Active filtering of physiological motion in robotized surgery using predictive control. IEEE Transactions on Robotics. https://doi.org/10.1109/tro.2004.833812
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.